Inspection 348596800 OPENED NOV 17, 2025Closed
7190 Oakland Mills Road Suite 3, Columbia, MD 21046 · Fish and Seafood Merchant Wholesalers · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.28(b)(11)(ii) · Fall protection in general industry |
Serious | $1,200 | $960 | Feb 20, 2026 | Final |
| Citation 1, item 1b 29 CFR 1910.29(b)(1) · Fall protection systems in general industry |
Serious | $0 | $0 | Feb 20, 2026 | Final |
| Citation 1, item 1c 29 CFR 1910.29(b)(2) · Fall protection systems in general industry |
Serious | $0 | $0 | Feb 20, 2026 | Final |
| Citation 1, item 2a 29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements |
Serious | $1,400 | $980 | Feb 20, 2026 | Final |
| Citation 1, item 2b 29 CFR 1910.133(a)(1) · Eye and face protection |
Serious | $0 | $0 | Feb 20, 2026 | Final |
| Citation 1, item 2c 29 CFR 1910.138(a) · Gloves and hand protection |
Serious | $0 | $0 | Feb 20, 2026 | Final |
| Citation 1, item 3 29 CFR 1910.151(c) · First aid and eyewash |
Serious | $1,200 | $720 | Feb 20, 2026 | Final |
| Citation 1, item 4 29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks |
Serious | $1,400 | $840 | Feb 20, 2026 | Final |
| Citation 1, item 5 29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements |
Serious | $1,200 | $840 | Feb 20, 2026 | Final |
| Citation 1, item 6a 29 CFR 1910.1200(e)(1) · Hazard communication |
Serious | $1,400 | $1,120 | Feb 20, 2026 | Final |
| Citation 1, item 6b 29 CFR 1910.1200(g)(1) · Hazard communication |
Serious | $0 | $0 | Feb 20, 2026 | Final |
| Citation 1, item 6c 29 CFR 1910.1200(h)(1) · Hazard communication |
Serious | $0 | $0 | Feb 20, 2026 | Final |
| Citation 2, item 1 29 CFR 1910.36(d)(1) · Exit route design |
Other-than-serious | $0 | $0 | Feb 20, 2026 | Final |
| Citation 2, item 2 29 CFR 1910.37(a)(3) · Exit routes |
Other-than-serious | $0 | $0 | Feb 20, 2026 | Final |
| Citation 2, item 3 29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements |
Other-than-serious | $0 | $0 | Feb 20, 2026 | Final |
| Citation 2, item 4 29 CFR 1910.157(c)(1) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Feb 20, 2026 | Final |
| Citation 2, item 5 29 CFR 1910.157(e)(2) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Feb 20, 2026 | Final |
| Citation 2, item 6 29 CFR 1910.178(l)(6) · Forklifts and other powered industrial trucks |
Other-than-serious | $0 | $0 | Feb 20, 2026 | Final |
| Citation 2, item 7 29 CFR 1910.244(a)(1)(ii) · Other portable tools and equipment |
Other-than-serious | $0 | $0 | Feb 20, 2026 | Final |
| Citation 2, item 8 29 CFR 1910.305(b)(1)(i) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Feb 20, 2026 | Final |
| Citation 2, item 9 29 CFR 1910.305(c)(4) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Feb 20, 2026 | Final |
| Citation 2, item 10 29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Feb 20, 2026 | Final |
| Citation 2, item 11 29 CFR 1910.305(j)(1)(i) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Feb 20, 2026 | Final |
| Citation 2, item 12 29 CFR 1910.1200(e)(1)(i) · Hazard communication |
Other-than-serious | $0 | $0 | Feb 20, 2026 | Final |