OSHA SearchOSHA records by employer

Sun River Electric Cooperative Inc.: OSHA inspections and violations

Conrad, Montana · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

1inspections
1citation items
$2,305current penalties
Aug 12, 2024last inspection

OSHA inspectors have visited Sun River Electric Cooperative Inc. in Montana one time.

It opened on Aug 12, 2024 after a fatality or catastrophe, in Conrad.

In all, OSHA issued 1 citation item: 1 serious.

The proposed penalties came to $4,610; today they stand at $2,305, 50% less.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Sun River Electric Cooperative Inc. averages $2,305 across 1 cited inspection.

1 inspection on this page followed a fatal incident.

Sun River Electric Cooperative Inc.: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Montana · latest 90 days of OSHA records

29employers cited

Get notified the morning OSHA posts each new citation in Montana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Montana

Checking a subcontractor, a client or your own company? Watch Sun River Electric Cooperative Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347680928 OPENED AUG 12, 2024Closed

Fatality or catastrophe · Complete · Safety · 21 employees at the site · Closed Nov 26, 2024

Midway Colony, Conrad, MT 59425 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Incident on Aug 9, 2024 (fatal): Employee falls due to collapsing power pole during power lin

At 11:15 a.m. on August 9, 2024, an employee was removing an old power line and replacing it with a new one when the power pole collapsed. The employee fell to the ground, suffering blunt force trauma from the impact with the ground, and was killed.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.269(q)(1)(i) · Electric power generation, transmission, and distribution
Serious$4,610$2,305Oct 31, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.269 · Electric power generation, transmission, and distribution

29 CFR 1910.269(q)(1)(i)

(1) General. (i) Before allowing employees to subject elevated structures, such as poles or towers, to such stresses as climbing or the installation or removal of equipment may impose, the employer shall ascertain that the structures are capable of sustaining the additional or unbalanced stresses. If the pole or other structure cannot withstand the expected loads, the employer shall brace or otherwise support the pole or structure so as to prevent failure.