Sundstrom Pressed Steel Co. has 10 OSHA inspections on record in Illinois, the first in 1973.
OSHA's last visit started on Mar 8, 2017 on a referral, in Chicago.
Across those inspections OSHA issued 57 citation items: 18 serious and 39 other-than-serious.
OSHA proposed $22,490 in penalties. After settlements and reviews the total is $13,636, down 39%.
Most often, OSHA cited 1910.217, mechanical power presses (12 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Sundstrom Pressed Steel Co. averages $3,188 over 2 cited inspections in that time.
Sundstrom Pressed Steel Co. also files yearly injury logs with OSHA, summarized below.
It reported 1 severe injury to OSHA since 2015.
Citation items per year, by inspection date.
Illinois · latest 90 days of OSHA records
421employers cited
Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.
Checking a subcontractor, a client or your own company? Watch Sundstrom Pressed Steel Co. and get notified the morning OSHA posts a new citation for it.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Chicago site logged 0 recordable injuries or illnesses among about 19 workers: 0.0 per 100 full-time workers, against a median of 4.0 for its industry.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Sundstrom Pressed Steel Co.
Chicago · 2025
19
0
0
0.0
4.0
Included with any plan: 7 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.
(2) Cleaning. All spraying areas shall be kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary. Scrapers, spuds, or other such tools used for cleaning purposes shall be of nonsparking material.
(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.
Alert subscribers get notified of each newly cited employer in Illinois the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.