OSHA SearchOSHA records by employer

Sunrun Solar: OSHA inspections and violations

Woburn, Massachusetts · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

1inspections
4citation items
$171,640current penalties
Jul 17, 2021last inspection

OSHA inspectors have visited Sunrun Solar in Massachusetts one time.

It opened on Jul 17, 2021 as a planned inspection, in Woburn.

In all, OSHA issued 4 citation items: 2 serious and 2 repeat.

The penalties, $171,640 in total, stand where OSHA first set them.

Among construction employers, the typical cited inspection since 2015 ends with a $3,079 penalty. Sunrun Solar averages $171,640 across 1 cited inspection.

Sunrun Solar: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

Want to know if OSHA cites Sunrun Solar again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 345431852 OPENED JUL 17, 2021Closed

Planned · Partial · Safety · 100 employees at the site · Closed Sep 18, 2025

29 S Bedford St, Woburn, MA 01801 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$10,728$10,728Oct 28, 2021Final
Citation 1, item 2
29 CFR 1926.416(a)(1) · Electrical safety in construction
Serious$10,728$10,728Oct 28, 2021Final
Citation 2, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$75,092$75,092Oct 28, 2021Final
Citation 2, item 2
29 CFR 1926.503(a)(2)(ii) · Fall protection training in construction
Repeat$75,092$75,092Oct 28, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.416(a)(1)

(a) Protection of employees. (1) No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(13)

(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.

29 CFR 1926.503 · Fall protection training in construction

Other electrical contractors and other wiring installation contractors employers in Massachusetts

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.