OSHA SearchOSHA records by employer

Suntree Technologies, Inc.: OSHA inspections and violations

Gainesville, Florida · Water and Sewer Line and Related Structures Construction · NAICS 237110

2inspections
9citation items
$18,525current penalties
Apr 6, 2017last inspection

Suntree Technologies, Inc. has 2 OSHA inspections on record in Florida, the first in 2014.

OSHA's last visit started on Apr 6, 2017 as a planned inspection, in Cocoa.

Across those inspections OSHA issued 9 citation items: 6 serious and 3 other-than-serious.

OSHA proposed $30,875 in penalties. After settlements and reviews the total is $18,525, down 40%.

Most often, OSHA cited 1926.501, fall protection in construction (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Suntree Technologies, Inc. averages $7,605 over 1 cited inspection in that time.

Suntree Technologies, Inc.: OSHA citation items per year, 2014 to 2017
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

338employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Suntree Technologies, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342230778 OPENED APR 6, 2017Closed

Planned · Complete · Safety · 29 employees at the site · Closed Jul 7, 2017

798 Clearlake Rd., Cocoa, FL 32922 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$8,873$5,324May 17, 2017Final
Citation 1, item 2
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Serious$3,802$2,281May 17, 2017Final
Citation 2, item 1
29 CFR 1910.134(c)(1) · Respiratory protection
Other-than-serious$0$0May 17, 2017Final
Citation 2, item 2
29 CFR 1910.157(g)(1) · Portable fire extinguishers
Other-than-serious$0$0May 17, 2017Final
Citation 2, item 3
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Other-than-serious$0$0May 17, 2017Final

Inspection 339562894 OPENED JAN 28, 2014Closed

Unprogrammed related · Complete · Safety · 24 employees at the site · Closed Jul 30, 2014

Se 4th Street And Dupont Avenue, Gainesville, FL 32601 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$4,200$2,520Jun 23, 2014Final
Citation 1, item 2
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$4,900$2,940Jun 23, 2014Final
Citation 1, item 3
29 CFR 1926.501(b)(6) · Fall protection in construction
Serious$4,900$2,940Jun 23, 2014Final
Citation 1, item 4
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$4,200$2,520Jun 23, 2014Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(1)

(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.157(g)(1)

(g) Training and education. (1) Where the employer has provided portable fire extinguishers for employee use in the workplace, the employer shall also provide an educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(f)(2)

(2) Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.501 · Fall protection in construction

OSH Act Section 5 · General Duty Clause

Other water and sewer line and related structures construction employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.