Superior Lighting, Inc.: OSHA inspections and violations
Omaha, Nebraska · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210
4inspections
6citation items
$31,808current penalties
Aug 6, 2021last inspection
OSHA has inspected Superior Lighting, Inc. 4 times in Nebraska since 2005.
The latest one began on Aug 6, 2021 on a referral, in Omaha.
Those inspections ended with 6 citation items: 5 serious and 1 other-than-serious.
Penalties were first proposed at $36,851 and now stand at $31,808, 14% lower after settlements or reviews.
Electrical safety in construction comes up most often in these citations: 2 items under 1926.416.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Superior Lighting, Inc. averages $18,923 (1 cited inspection).
Superior Lighting, Inc. also files yearly injury logs with OSHA, summarized below.
It reported 1 severe injury to OSHA since 2015.
Citation items per year, by inspection date.
Nebraska · latest 90 days of OSHA records
33employers cited
2 of them in the same industry
Get notified the morning OSHA posts each new citation in Nebraska: the employer, the site address, the rules broken and the penalty.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2020, the Omaha site logged 4 recordable injuries or illnesses among about 75 workers: 7.8 per 100 full-time workers, against a median of 1.8 for its industry. Those cases cost 336 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Superior Lighting Inc.
Omaha · 2020
75
4
4
7.8
1.8
Included with any plan: 1 more yearly log from these sites, back to 2018, with each site's average rate over its latest three years. Already a subscriber? Sign in.
Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.
Feb 5, 2018, Omaha: Hospitalization · soreness, pain, hurt-nonspecified injury · multiple body parts, n.e.c.
An employee was on a ladder removing a light fixture with a screwdriver when he fell backwards off the ladder from approximately 4 feet, injuring his right arm and pelvis.
The rules behind these citations
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
(B) A qualified person shall use test equipment to test the circuit elements and electrical parts of equipment to which employees will be exposed and shall verify that the circuit elements and equipment parts are deenergized. The test shall also determine if any energized condition exists as a result of inadvertently induced voltage or unrelated voltage backfeed even though specific parts of the circuit have been deenergized and presumed to be safe. If the circuit to be tested is over 600 volts, nominal, the test equipment shall be checked for proper operation immediately before and immediately after this test.
29 CFR 1910.67 · Vehicle-mounted elevating and rotating work platforms
29 CFR 1910.67(c)(2)(v)
(v) A personal fall arrest or travel restraint system that meets the requirements in subpart I of this part shall be worn and attached to the boom or basket when working from an aerial lift.
(2) The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.
Alert subscribers get notified of each newly cited employer in Nebraska the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.