Supreme Masonry, Inc.: OSHA inspections and violations

Aurora, Illinois · Masonry Contractors · NAICS 238140

1inspections
4citation items
$3,750current penalties
Mar 27, 2026last inspection

Supreme Masonry, Inc. has one OSHA inspection on record in Illinois.

OSHA opened it on Mar 27, 2026, in Aurora.

From that inspection OSHA issued 4 citation items: 2 serious and 2 other-than-serious.

OSHA proposed $11,350 in penalties. After settlements and reviews the total is $3,750, down 67%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Supreme Masonry, Inc. averages $3,750 over 1 cited inspection in that time.

Supreme Masonry, Inc.: OSHA citation items per year, 2026 to 2026
Citation items per year, by inspection date.

Illinois · latest 90 days of OSHA records

416employers cited

11 of them in the same industry

Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Illinois

Checking a subcontractor, a client or your own company? Watch Supreme Masonry, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348839168 OPENED MAR 27, 2026Closed

Inspection · Partial · Safety · 3 employees at the site · Closed Jun 29, 2026

550 2nd Ave., Aurora, IL 60505 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.178(l)(1)(ii) · Forklifts and other powered industrial trucks
Other-than-serious$2,270$0May 11, 2026Final
Citation 1, item 2
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$2,270$0May 11, 2026Final
Citation 1, item 3
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,838$1,500May 11, 2026Final
Citation 1, item 4
29 CFR 1926.451(g)(1)(vi) · Scaffolds, general requirements
Serious$3,972$2,250May 11, 2026Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.178(l)(1)(ii)

(ii) Prior to permitting an employee to operate a powered industrial truck (except for training purposes), the employer shall ensure that each operator has successfully completed the training required by this paragraph (l), except as permitted by paragraph (l)(5).

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.