OSHA SearchOSHA records by employer

Sweeney Drywall Finishes Corp.: OSHA inspections and violations

Worcester, Massachusetts · Drywall and Insulation Contractors · NAICS 238310

8inspections
29citation items
$18,866current penalties
Mar 7, 2023last inspection

Since 1998, OSHA inspectors have visited Sweeney Drywall Finishes Corp. in Massachusetts 8 times.

The most recent inspection opened on Mar 7, 2023 on a referral, in Lexington.

In all, OSHA issued 29 citation items: 25 serious and 4 other-than-serious.

The proposed penalties came to $33,719; today they stand at $18,866, 44% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 5 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Sweeney Drywall Finishes Corp. averages $6,945 across 2 cited inspections.

Sweeney Drywall Finishes Corp.: OSHA citation items per year, 1998 to 2023
Citation items per year, by inspection date.

Massachusetts · latest 90 days of OSHA records

256employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Massachusetts: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Massachusetts

Checking a subcontractor, a client or your own company? Watch Sweeney Drywall Finishes Corp. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346548332 OPENED MAR 7, 2023Closed

Referral · Complete · Safety · 10 employees at the site · Closed Mar 22, 2023

110 Hartwell Ave, Lexington, MA 02420 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344706445 OPENED MAR 3, 2020Closed

Unprogrammed other · Complete · Health · 6 employees at the site · Closed Mar 11, 2020

1186-1198 Commonwealth Avenue, Allston, MA 02134 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 340660455 OPENED MAY 19, 2015Closed

Unprogrammed other · Complete · Safety · 8 employees at the site · Closed Aug 12, 2015

Chao Center - Harvard Business School 1 Western Avenue, Allston, MA 02134 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.302(e)(1) · Power-operated hand tools
Serious$2,550$1,275Jul 24, 2015Final
Citation 1, item 2
29 CFR 1926.454(a) · Scaffold training
Serious$2,550$1,275Jul 24, 2015Final

Inspection 340441948 OPENED FEB 27, 2015Closed

Complaint · Complete · Safety · 22 employees at the site · Closed Dec 4, 2015

505 Washington Street, Boston, MA 02108 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$6,300$3,780Jul 14, 2015Final
Citation 1, item 2
29 CFR 1926.501(b)(4)(i) · Fall protection in construction
Serious$6,300$3,780Jul 14, 2015Final
Citation 1, item 3
29 CFR 1926.502(i)(3) · Fall protection systems
Serious$6,300$3,780Jul 14, 2015Final

Inspection 306811027 OPENED FEB 25, 2004Closed

Unprogrammed other · Partial · Safety · 6 employees at the site · Closed May 11, 2004

188 Longwood Avenue, Boston, MA 02215 · Finish Carpentry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.25(a) · Housekeeping
Serious$600$300Apr 29, 2004Closed
Citation 1, item 2
29 CFR 1926.416(b)(2) · Electrical safety in construction
Serious$600$300Apr 29, 2004Closed

Inspection 304239197 OPENED FEB 13, 2002Closed

Unprogrammed other · Complete · Health · 2 employees at the site · Closed Apr 17, 2002

25 Fox Road, Dedham, MA 02026 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(16) · Ladders in construction
Serious$382$191Apr 2, 2002Closed
Citation 2, item 1
29 CFR 1926.54(b) · Nonionizing radiation
Other-than-serious$0$0Apr 2, 2002Closed

Inspection 102769916 OPENED JUL 10, 1998Closed

Unprogrammed related · Complete · Safety · 100 employees at the site · Closed Aug 26, 1998

Assumption College, Worcester, MA 01609 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$875$437Aug 11, 1998Closed
Citation 1, item 2
29 CFR 1926.25(a) · Housekeeping
Serious$262$262Aug 11, 1998Closed
Citation 1, item 3
29 CFR 1926.100(a) · Hard hats in construction
Serious$875$438Aug 11, 1998Closed
Citation 1, item 4a
29 CFR 1926.150(a)(1) · Fire protection
Serious$525$262Aug 11, 1998Closed
Citation 1, item 4b
29 CFR 1926.150(a)(2) · Fire protection
Serious$0$0Aug 11, 1998Closed
Citation 1, item 4c
29 CFR 1926.150(a)(3) · Fire protection
Serious$0$0Aug 11, 1998Closed
Citation 1, item 4d
29 CFR 1926.150(c)(1)(i) · Fire protection
Serious$0$0Aug 11, 1998Closed
Citation 1, item 5a
29 CFR 1926.405(a)(2)(iii) · Job-site wiring
Serious$525$262Aug 11, 1998Closed
Citation 1, item 5b
29 CFR 1926.416(b)(2) · Electrical safety in construction
Serious$0$0Aug 11, 1998Closed
Citation 1, item 6a
29 CFR 1926.416(a)(1) · Electrical safety in construction
Serious$525$262Aug 11, 1998Closed
Citation 1, item 6b
29 CFR 1926.416(a)(3) · Electrical safety in construction
Serious$0$0Aug 11, 1998Closed
Citation 1, item 7
29 CFR 1926.501(b)(14) · Fall protection in construction
Serious$875$437Aug 11, 1998Closed
Citation 2, item 1
29 CFR 1926.34(b) · Means of egress
Other-than-serious$0$0Aug 11, 1998Closed
Citation 2, item 2
29 CFR 1926.34(c) · Means of egress
Other-than-serious$0$0Aug 11, 1998Closed

Inspection 102769957 OPENED JUN 25, 1998Closed

Complaint · Partial · Safety · 100 employees at the site · Closed Aug 20, 1998

Assumption College, Worcester, MA 01609 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$875$437Aug 5, 1998Closed
Citation 1, item 2
29 CFR 1926.451(c)(1)(ii) · Scaffolds, general requirements
Serious$525$262Aug 5, 1998Closed
Citation 1, item 3
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$525$251Aug 5, 1998Closed
Citation 1, item 4
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$875$437Aug 5, 1998Closed
Citation 1, item 5
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$875$438Aug 5, 1998Closed
Citation 2, item 1
29 CFR 1910.1200(g)(1) · Hazard communication
Other-than-serious$0$0Aug 5, 1998Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(g)(1)

(g) Safety data sheets. (1) Chemical manufacturers and importers shall obtain or develop a safety data sheet for each hazardous chemical they produce or import. Employers shall have a safety data sheet in the workplace for each hazardous chemical which they use.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(16)

(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.

29 CFR 1926.150 · Fire protection

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.25 · Housekeeping

29 CFR 1926.302 · Power-operated hand tools

29 CFR 1926.34 · Means of egress

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.54 · Nonionizing radiation

Other drywall and insulation contractors employers in Massachusetts

Alert subscribers get notified of each newly cited employer in Massachusetts the morning it is posted. See the alert plans.