OSHA SearchOSHA records by employer

System Transport, Inc.: OSHA inspections and violations

Denver, Colorado · General Freight Trucking, Local · NAICS 484110

3inspections
6citation items
$36,779current penalties
Mar 23, 2026last inspection

Since 2000, OSHA inspectors have visited System Transport, Inc. in Colorado 3 times.

The most recent inspection opened on Mar 23, 2026 after a complaint, in Denver.

In all, OSHA issued 6 citation items: 6 serious.

The proposed penalties came to $42,205; today they stand at $36,779, 13% less.

The rule cited most here is 1910.305 (electrical wiring methods), 2 times.

Among transportation and warehousing employers, the typical cited inspection since 2015 ends with a $2,415 penalty. System Transport, Inc. averages $18,389 across 2 cited inspections.

1 inspection on this page followed a fatal incident.

System Transport, Inc.: OSHA citation items per year, 2000 to 2026
Citation items per year, by inspection date.

Colorado · latest 90 days of OSHA records

132employers cited

Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Colorado

Checking a subcontractor, a client or your own company? Watch System Transport, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348828229 OPENED MAR 23, 2026Closed

Complaint · Partial · Safety · 17 employees at the site · Closed Sep 17, 2026

6560 Vine Court, Denver, CO 80229 · General Freight Trucking, Local · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.29(b)(2)(i) · Fall protection systems in general industry
Serious$8,038$5,627Aug 18, 2026Final
Citation 1, item 2a
29 CFR 1910.305(b)(2) · Electrical wiring methods
Serious$10,050$7,035Aug 18, 2026Final
Citation 1, item 2b
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$0$0Aug 18, 2026Final

Inspection 348413303 OPENED AUG 1, 2025Closed

Complaint · Partial · Safety · 17 employees at the site · Closed Feb 10, 2026

6560 Vine Court, Denver, CO 80229 · General Freight Trucking, Local · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Serious$8,038$8,038Jan 7, 2026Final
Citation 1, item 2
29 CFR 1910.178(l)(1)(ii) · Forklifts and other powered industrial trucks
Serious$10,050$10,050Jan 7, 2026Final
Citation 1, item 3
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$6,029$6,029Jan 7, 2026Final

Inspection 303618912 OPENED SEP 20, 2000Closed

Accident · Partial · Safety · 471 employees at the site · Closed Dec 7, 2000

1253 Santa Fe Trail, Elizabeth, CO 80107 · OSHA's record · Phone and website on Google Maps

Incident on Sep 19, 2000 (fatal): Employee killed when crushed by fork lift

Employee #1 was helping a homeowner unload material. Employee #1 placed his body on the back of the fork truck for counterbalance, but was crushed as the linkag e of the fork truck came down. Employee #1 was killed.

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.157(e)(3)

(3) The employer shall assure that portable fire extinguishers are subjected to an annual maintenance check. Stored pressure extinguishers do not require an internal examination. The employer shall record the annual maintenance date and retain this record for one year after the last entry or the life of the shell, whichever is less. The record shall be available to the Assistant Secretary upon request.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.178(l)(1)(ii)

(ii) Prior to permitting an employee to operate a powered industrial truck (except for training purposes), the employer shall ensure that each operator has successfully completed the training required by this paragraph (l), except as permitted by paragraph (l)(5).

29 CFR 1910.29 · Fall protection systems in general industry

29 CFR 1910.29(b)(2)(i)

(i) Midrails are installed at a height midway between the top edge of the guardrail system and the walking-working surface;

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

Other general freight trucking, local employers in Colorado

Alert subscribers get notified of each newly cited employer in Colorado the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.