Inspection 344150750 OPENED JUL 9, 2019Closed
31 Privet Street, Pawtucket, RI 02860 · Custom Architectural Woodwork and Millwork Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Pawtucket, Rhode Island · Custom Architectural Woodwork and Millwork Manufacturing · NAICS 337212
OSHA has inspected T & C Woodworking, Inc. 2 times in Rhode Island since 2017.
The latest one began on Jul 9, 2019 to follow up on an earlier case, in Pawtucket.
Those inspections ended with 14 citation items: 14 serious.
Penalties were first proposed at $14,488 and now stand at $10,000, 31% lower after settlements or reviews.
Spray painting and finishing comes up most often in these citations: 7 items under 1910.107.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and T & C Woodworking, Inc. averages $10,000 (1 cited inspection).
Rhode Island · latest 90 days of OSHA records
76employers cited
Get notified the morning OSHA posts each new citation in Rhode Island: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Rhode Island
Checking a subcontractor, a client or your own company? Watch T & C Woodworking, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company31 Privet Street, Pawtucket, RI 02860 · Custom Architectural Woodwork and Millwork Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
31 Privet Street, Pawtucket, RI 02860 · Custom Architectural Woodwork and Millwork Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.107(b)(5)(i) · Spray painting and finishing |
Serious | $3,622 | $2,500 | Nov 6, 2017 | Final |
| Citation 1, item 1b 29 CFR 1910.107(b)(5)(i) · Spray painting and finishing |
Serious | $0 | $0 | Nov 6, 2017 | Final |
| Citation 1, item 1c 29 CFR 1910.107(d)(12) · Spray painting and finishing |
Serious | $0 | $0 | Nov 6, 2017 | Final |
| Citation 1, item 2a 29 CFR 1910.107(c)(6) · Spray painting and finishing |
Serious | $3,622 | $2,500 | Nov 6, 2017 | Final |
| Citation 1, item 2b 29 CFR 1910.107(e)(2) · Spray painting and finishing |
Serious | $0 | $0 | Nov 6, 2017 | Final |
| Citation 1, item 2c 29 CFR 1910.107(e)(9) · Spray painting and finishing |
Serious | $0 | $0 | Nov 6, 2017 | Final |
| Citation 1, item 2d 29 CFR 1910.107(g)(2) · Spray painting and finishing |
Serious | $0 | $0 | Nov 6, 2017 | Final |
| Citation 1, item 3a 29 CFR 1910.134(c)(1) · Respiratory protection |
Serious | $3,622 | $2,500 | Nov 6, 2017 | Final |
| Citation 1, item 3b 29 CFR 1910.134(d)(1)(iii) · Respiratory protection |
Serious | $0 | $0 | Nov 6, 2017 | Final |
| Citation 1, item 3c 29 CFR 1910.134(e)(1) · Respiratory protection |
Serious | $0 | $0 | Nov 6, 2017 | Final |
| Citation 1, item 3d 29 CFR 1910.134(f)(2) · Respiratory protection |
Serious | $0 | $0 | Nov 6, 2017 | Final |
| Citation 1, item 4a 29 CFR 1910.1200(e)(1) · Hazard communication |
Serious | $3,622 | $2,500 | Nov 6, 2017 | Final |
| Citation 1, item 4b 29 CFR 1910.1200(g)(8) · Hazard communication |
Serious | $0 | $0 | Nov 6, 2017 | Final |
| Citation 1, item 4c 29 CFR 1910.1200(h)(1) · Hazard communication |
Serious | $0 | $0 | Nov 6, 2017 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.107(b)(5)(i)
(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.
29 CFR 1910.107(c)(6)
(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.
29 CFR 1910.107(d)(12)
(12) Drying spaces. Freshly sprayed articles shall be dried only in spaces provided with adequate ventilation to prevent the formation of explosive vapors. In the event adequate and reliable ventilation is not provided such drying spaces shall be considered a spraying area. See also paragraph (j) of this section.
Alert subscribers get notified of each newly cited employer in Rhode Island the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.