Inspection 349000141 OPENED JUN 16, 2026Open
16400 Gateway West Blvd, Clint, TX 79836 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
T-Dyne Contractors, LLC has 4 OSHA inspections on record in Texas, the first in 2015.
OSHA's last visit started on Jun 16, 2026 after a complaint, in Clint, and the case has not closed yet.
Across those inspections OSHA issued 5 citation items: 4 serious and 1 other-than-serious.
OSHA proposed $22,944 in penalties. After settlements and reviews the total is $15,877, down 31%.
For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. T-Dyne Contractors, LLC averages $5,292 over 3 cited inspections in that time.
T-Dyne Contractors, LLC also files yearly injury logs with OSHA, summarized below.
It reported 2 severe injuries to OSHA since 2015.
The Wage and Hour Division has 1 case on it since 2015, with $16,014 in back wages owed to workers.
Texas · latest 90 days of OSHA records
401employers cited
10 of them in the same industry
Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Texas
Checking a subcontractor, a client or your own company? Watch T-Dyne Contractors, LLC and get notified the morning OSHA posts a new citation for it.
Watch this company16400 Gateway West Blvd, Clint, TX 79836 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
Gateway Estates Subdivision, El Paso, TX 79938 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.602(c)(1)(vii) · Earthmovers and forklifts in construction |
Serious | $8,067 | $5,000 | Apr 3, 2024 | Final |
1930 Joe Battle, El Paso, TX 79936 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks |
Other-than-serious | $877 | $877 | Mar 24, 2023 | Final |
14400 Pebble Hills, El Paso, TX 79936 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.405(b)(2) · Job-site wiring |
Serious | $4,200 | $3,000 | Jul 13, 2015 | Final |
| Citation 1, item 2 29 CFR 1926.451(f)(3) · Scaffolds, general requirements |
Serious | $4,900 | $3,500 | Jul 13, 2015 | Final |
| Citation 1, item 3 29 CFR 1926.454(a) · Scaffold training |
Serious | $4,900 | $3,500 | Jul 13, 2015 | Final |
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2023, the El Paso site logged 5 recordable injuries or illnesses among about 40 workers: 11.7 per 100 full-time workers, against a median of 1.8 for its industry. Those cases cost 1 days away from work.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| 1525 Goodyear Dr El Paso · 2023 | 40 | 5 | 1 | 11.7 | 1.8 |
| T Dyne Contractors LL El Paso · 2022 | 40 | 2 | 1 | 17.4 | 1.8 |
| T-Dyne Office El Paso · 2017 | 53 | 6 | 3 | 441.7 | 1.8 |
Included with any plan: 2 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.
See plansEmployers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 2 reports on file.
Mar 17, 2023, El Paso: Hospitalization · soreness, pain, hurt-nonspecified injury · hip(s)
An employee was climbing up a hatch ladder to a roof. He slipped on a rung and fell to the ground, landing on his measuring tape and sustaining a hip injury.
Feb 16, 2015, El Paso: Hospitalization · fractures · multiple body parts, n.e.c.
Employee was working from a scissor lift approximately 12 feet high when it collapsed and ejected the employee onto a concrete slab. The employee was admitted to the hospital with a broken arm and a broken back.
Cases by the Labor Department's Wage and Hour Division since 2015: unpaid minimum wage or overtime, child labor, family leave and more.
| Period reviewed | Violations | Workers owed | Back wages | Penalties |
|---|---|---|---|---|
| Aug 8, 2017 to Aug 6, 2019 El Paso | 27 | 25 | $16,014 | $0 |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.178(l)(1)(i)
(l) Operator training. (1) Safe operation. (i) The employer shall ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l).
29 CFR 1926.405(b)(2)
(2) Covers and canopies. All pull boxes, junction boxes, and fittings shall be provided with covers. If metal covers are used, they shall be grounded. In energized installations each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.
29 CFR 1926.451(f)(3)
(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.
Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.