OSHA SearchOSHA records by employer

Tank Components Industries: OSHA inspections and violations

Springfield, Missouri · Metal Tank (Heavy Gauge) Manufacturing · NAICS 332420

3inspections
9citation items
$18,375current penalties
Mar 25, 2015last inspection

Since 2012, OSHA inspectors have visited Tank Components Industries in Missouri 3 times.

The most recent inspection opened on Mar 25, 2015 on a referral, in Springfield.

In all, OSHA issued 9 citation items: 9 serious.

The proposed penalties came to $27,650; today they stand at $18,375, 34% less.

The rule cited most here is 1910.305 (electrical wiring methods), 2 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Tank Components Industries averages $5,880 across 1 cited inspection.

Tank Components Industries also files yearly injury logs with OSHA, summarized below.

Tank Components Industries: OSHA citation items per year, 2012 to 2015
Citation items per year, by inspection date.

Want to know if OSHA cites Tank Components Industries again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 340492404 OPENED MAR 25, 2015Closed

Referral · Partial · Safety · 60 employees at the site · Closed Jul 28, 2015

2000 N. Alliance Ave, Springfield, MO 65803 · Metal Tank (Heavy Gauge) Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$4,900$2,940Jun 11, 2015Final
Citation 1, item 2
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$4,900$2,940Jun 11, 2015Final

Inspection 338947740 OPENED MAR 6, 2013Closed

Planned · Complete · Safety · 52 employees at the site · Closed Apr 24, 2013

4520 W. Kearney St., Ste.100, Springfield, MO 65803 · Metal Tank (Heavy Gauge) Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.179(j)(2)(iii) · Overhead and gantry cranes
Serious$2,625$1,838Apr 5, 2013Final
Citation 1, item 2
29 CFR 1910.179(j)(2)(iv) · Overhead and gantry cranes
Serious$2,625$1,838Apr 5, 2013Final
Citation 1, item 3 Serious$2,625$1,838Apr 5, 2013Final
Citation 1, item 4
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Serious$2,100$1,470Apr 5, 2013Final
Citation 1, item 5
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Serious$1,575$1,102Apr 5, 2013Final

Inspection 335420816 OPENED JUL 19, 2012Closed

Planned · Partial · Safety · 52 employees at the site · Closed Sep 5, 2012

4520 W. Kearney St., Ste.100, Springfield, MO 65803 · Metal Tank (Heavy Gauge) Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Serious$2,800$1,960Aug 20, 2012Final
Citation 1, item 2
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$3,500$2,450Aug 20, 2012Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2023, the Springfield site logged 3 recordable injuries or illnesses among about 67 workers: 4.5 per 100 full-time workers, against a median of 3.6 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Tank Components Industries
Springfield · 2023
67 304.53.6

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.179(j)(2)(iii)

(iii) Hooks with deformation or cracks. Visual inspection daily; monthly inspection with a certification record which includes the date of inspection, the signature of the person who performed the inspection and the serial number, or other identifier, of the hook inspected. For hooks with cracks or having more than 15 percent in excess of normal throat opening or more than 10° twist from the plane of the unbent hook refer to paragraph (l)(3)(iii)(a) of this section.

29 CFR 1910.179(j)(2)(iv)

(iv) Hoist chains, including end connections, for excessive wear, twist, distorted links interfering with proper function, or stretch beyond manufacturer's recommendations. Visual inspection daily; monthly inspection with a certification record which includes the date of inspection, the signature of the person who performed the inspection and an identifier of the chain which was inspected.

29 CFR 1910.184 · Slings

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

OSH Act Section 5 · General Duty Clause

Other metal tank (heavy gauge) manufacturing employers in Missouri

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.