OSHA SearchOSHA records by employer

Team Industries, Inc.: OSHA inspections and violations

Kaukauna, Wisconsin · Fabricated Pipe and Pipe Fitting Manufacturing · NAICS 332996

11inspections
53citation items
$25,420current penalties
Dec 31, 2020last inspection

OSHA has inspected Team Industries, Inc. 11 times in Wisconsin since 1991.

The latest one began on Dec 31, 2020 to monitor an earlier case, in Kaukauna.

Those inspections ended with 53 citation items: 41 serious and 12 other-than-serious.

Penalties were first proposed at $55,200 and now stand at $25,420, 54% lower after settlements or reviews.

Permit-required confined spaces comes up most often in these citations: 11 items under 1910.146.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Team Industries, Inc. averages $400 (1 cited inspection).

1 inspection on this page followed a fatal incident.

Team Industries, Inc. also files yearly injury logs with OSHA, summarized below.

It reported 6 severe injuries to OSHA since 2015.

Team Industries, Inc.: OSHA citation items per year, 1991 to 2020
Citation items per year, by inspection date.

Wisconsin · latest 90 days of OSHA records

229employers cited

Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wisconsin

Checking a subcontractor, a client or your own company? Watch Team Industries, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345082846 OPENED DEC 31, 2020Closed

Monitoring · Partial · Safety · 258 employees at the site · Closed Jan 6, 2021

1200 Maloney Rd, Kaukauna, WI 54130 · Fabricated Pipe and Pipe Fitting Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344511050 OPENED DEC 16, 2019Closed

Monitoring · Partial · Safety · 298 employees at the site · Closed Dec 19, 2019

1200 Maloney Rd, Kaukauna, WI 54130 · Fabricated Pipe and Pipe Fitting Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341724953 OPENED AUG 25, 2016Closed

Referral · Partial · Safety · 360 employees at the site · Closed Oct 31, 2016

1200 Maloney Road, Kaukauna, WI 54130 · Fabricated Pipe and Pipe Fitting Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 340987189 OPENED OCT 15, 2015Closed

Referral · Partial · Safety · 300 employees at the site · Closed Jan 4, 2016

1200 Maloney Road, Kaukauna, WI 54130 · Fabricated Pipe and Pipe Fitting Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1910.305(b)(1)(i) · Electrical wiring methods
Other-than-serious$3,000$400Dec 11, 2015Final

Inspection 340467851 OPENED MAR 17, 2015Closed

Complaint · Partial · Safety · 270 employees at the site · Closed Apr 16, 2015

1200 Maloney Rd, Kaukauna, WI 54130 · Fabricated Pipe and Pipe Fitting Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 340261783 OPENED FEB 3, 2015Closed

Referral · Partial · Safety · 250 employees at the site · Closed Jun 16, 2015

1200 Maloney Rd, Kaukauna, WI 54130 · Fabricated Pipe and Pipe Fitting Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Feb 2, 2015 (fatal): Employee fallsl from a ladder.

At 11:15 a.m. on February 2, 2015, a 59 year old male employee working at a company that manufactures specialized pipes and vessels. The employee worked in the paint and blast department which was a new section of the building. The department was wide open in order to accommodate the large pipes which were stored/transported on wagons and trailers. The building's temperature at the time of the incident was approximately 60 degrees. The employee had climbed up on a mezzanine level in order to look for a spool part, which if available, would have been located. The employee used a fixed ladder to gain access to the mezzanine. After a few minutes of looking, the employee began to climb down the ladder and was near the top of the ladder when he fell backwards. The height from the mezzanine level to concrete floor was approximately 11 feet. The employee was transported to a medical center where he died later that day as a result of multiple blunt force injuries to the head, neck, chest, and abdomen resulting in a fatality.

No citations from this inspection.

Inspection 309836724 OPENED NOV 29, 2006Closed

Referral · Partial · Safety · 163 employees at the site · Closed Jun 21, 2007

1200 Maloney Road, Kaukauna, WI 54130 · Power Boiler and Heat Exchanger Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Nov 28, 2006: Painter injured when spool falls from support

At approximately 1:00 p.m. on November 28, 2006, a Painter was working alone in the Paint Building. The Painter was painting a 3,500-pound pipe section (spool) with an approximate 90 degree bend, 2 foot diameter and approximately 18 feet lo ng. The spool was elevated and stored on a wagon using railroad tracks as suppor ts. The spool was sitting on the railroad tracks without any securing materials. The spool was over half painted when it fell between the railroad tracks. There was no evidence of the spool falling because something hit it. It is believed t he spool had moved from a stable position of the bend section having contact poi nts on the railroad track support to a single contact point during the transport from another building. The Painter was located between the railroad track suppo rts and painting the lower half of the spool when the spool fell. It is believed the paint reduced the friction between the spool and railroad track support and allowed the spool to slide off the support. The Painter received severe trauma to the lower portion of her legs and was hospitalized.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1910.335(a)(1)(i) · Safeguards for personnel protection
Serious$1,050$1,050May 23, 2007Closed
Citation 2, item 1
29 CFR 1910.179(j)(1)(ii) · Overhead and gantry cranes
Other-than-serious$0$0May 23, 2007Closed
Citation 2, item 2
29 CFR 1910.303(g)(1)(iii) · Electrical equipment, general requirements
Other-than-serious$0$0May 23, 2007Closed

Inspection 114154230 OPENED JUL 18, 1995Closed

Accident · Partial · Health · 125 employees at the site · Closed Jul 19, 1996

1200 Maloney Road, Kaukauna, WI 54130 · OSHA's record · Phone and website on Google Maps

Incident on Jul 17, 1995: A welder was overcome by fumes

A welder was overcome by fumes.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.146(c)(1) · Permit-required confined spaces
Serious$3,500$5,500Oct 26, 1995Final
Citation 1, item 2
29 CFR 1910.146(c)(4) · Permit-required confined spaces
Serious$3,500$5,500Oct 26, 1995Final
Citation 1, item 3a
29 CFR 1910.146(c)(5)(iic) · Permit-required confined spaces
Serious$3,500$0Oct 26, 1995Final
Citation 1, item 3b
29 CFR 1910.146(d)(5)(i) · Permit-required confined spaces
Serious$0$0Oct 26, 1995Final
Citation 1, item 3c
29 CFR 1910.146(c)(5)(iie)(1) · Permit-required confined spaces
Serious$0$0Oct 26, 1995Final
Citation 1, item 3d
29 CFR 1910.146(d)(3)(iii) · Permit-required confined spaces
Serious$0$0Oct 26, 1995Final
Citation 1, item 4
29 CFR 1910.146(c)(5)(iid) · Permit-required confined spaces
Serious$3,500$0Oct 26, 1995Final
Citation 1, item 5a
29 CFR 1910.146(c)(5)(iih) · Permit-required confined spaces
Serious$3,500$0Oct 26, 1995Final
Citation 1, item 5b
29 CFR 1910.146(c)(7)(iii) · Permit-required confined spaces
Serious$0$0Oct 26, 1995Final
Citation 1, item 5c
29 CFR 1910.146(e)(1) · Permit-required confined spaces
Serious$0$0Oct 26, 1995Final
Citation 1, item 6
29 CFR 1910.146(g)(1) · Permit-required confined spaces
Serious$3,500$0Oct 26, 1995Final
Citation 1, item 7
29 CFR 1910.1200(h) · Hazard communication
Serious$3,500$0Oct 26, 1995Final
3 older inspections

Inspection 106502172 OPENED NOV 25, 1991Closed

Follow-up · Partial · Safety · 140 employees at the site · Closed Nov 20, 1992

1200 Maloney Road, Kaukauna, WI 54130 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$1,600$560Dec 6, 1991Final
Citation 1, item 2a
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$1,600$560Dec 6, 1991Final
Citation 1, item 2b
29 CFR 1910.147(c)(7)(iv) · Lockout/tagout
Serious$0$0Dec 6, 1991Final
Citation 2, item 1
29 CFR 1910.147(c)(4)(ii) · Lockout/tagout
Other-than-serious$0$0Dec 6, 1991Final
Citation 2, item 2
29 CFR 1910.147(f)(2)(i) · Lockout/tagout
Other-than-serious$0$0Dec 6, 1991Final

Inspection 103053211 OPENED JUL 15, 1991Closed

Complaint · Partial · Health · 182 employees at the site · Closed May 19, 1992

1200 Maloney Road, Kaukauna, WI 54130 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.24(b) · Fixed industrial stairs
Serious$1,750$900Aug 7, 1991Closed
Citation 1, item 2
29 CFR 1910.25(d)(2)(xii) · Portable wood ladders
Serious$1,750$850Aug 7, 1991Closed
Citation 1, item 3a Serious$3,500$1,750Aug 7, 1991Closed
Citation 1, item 3b Serious$0$0Aug 7, 1991Closed
Citation 1, item 3c Serious$0$0Aug 7, 1991Closed
Citation 1, item 3d Serious$0$0Aug 7, 1991Closed
Citation 1, item 4
29 CFR 1910.134(d)(2)(ii) · Respiratory protection
Serious$1,750$850Aug 7, 1991Closed
Citation 1, item 5
29 CFR 1910.151(c) · First aid and eyewash
Serious$1,050$500Aug 7, 1991Closed
Citation 1, item 6a
29 CFR 1910.1000(a)(3) · Air contaminants
Serious$1,750$900Aug 7, 1991Closed
Citation 1, item 6b
29 CFR 1910.1000(f)(2)(i) · Air contaminants
Serious$0$0Aug 7, 1991Closed
Citation 1, item 6c
29 CFR 1910.134(a)(2) · Respiratory protection
Serious$0$0Aug 7, 1991Closed
Citation 1, item 6d
29 CFR 1910.134(a)(2) · Respiratory protection
Serious$0$0Aug 7, 1991Closed
Citation 1, item 7a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$1,400$700Aug 7, 1991Closed
Citation 1, item 7b
29 CFR 1910.1200(h) · Hazard communication
Serious$0$0Aug 7, 1991Closed
Citation 2, item 1a Serious$3,500$1,800Aug 20, 1991Closed
Citation 2, item 1b Serious$0$0Aug 20, 1991Closed
Citation 2, item 1c Serious$0$0Aug 20, 1991Closed
Citation 2, item 1d Serious$0$0Aug 20, 1991Closed

Inspection 103051124 OPENED JUL 12, 1991Closed

Complaint · Complete · Safety · 182 employees at the site · Closed Nov 20, 1992

1200 Maloney Road, Kaukauna, WI 54130 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$1,400$700Aug 7, 1991Closed
Citation 1, item 2
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$1,050$600Aug 7, 1991Closed
Citation 1, item 3a
29 CFR 1910.213(h)(1) · Woodworking machinery
Serious$1,050$500Aug 7, 1991Closed
Citation 1, item 3b
29 CFR 1910.213(h)(4) · Woodworking machinery
Serious$0$0Aug 7, 1991Closed
Citation 1, item 4
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$1,050$500Aug 7, 1991Closed
Citation 1, item 5
29 CFR 1910.243(c)(1) · Guarding of portable powered tools
Serious$1,400$700Aug 7, 1991Closed
Citation 1, item 6
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$1,050$600Aug 7, 1991Closed
Citation 2, item 1
29 CFR 1910.22(b)(1) · General requirements
Other-than-serious$0$0Aug 7, 1991Closed
Citation 2, item 2
29 CFR 1910.25(d)(1)(x) · Portable wood ladders
Other-than-serious$0$0Aug 7, 1991Closed
Citation 2, item 3
29 CFR 1910.107(e)(2) · Spray painting and finishing
Other-than-serious$0$0Aug 7, 1991Closed
Citation 2, item 4
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Other-than-serious$0$0Aug 7, 1991Closed
Citation 2, item 5
29 CFR 1910.179(b)(5) · Overhead and gantry cranes
Other-than-serious$0$0Aug 7, 1991Closed
Citation 2, item 6 Other-than-serious$0$0Aug 7, 1991Closed
Citation 2, item 7
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Other-than-serious$0$0Aug 7, 1991Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Kaukauna site logged 4 recordable injuries or illnesses among about 278 workers: 1.6 per 100 full-time workers, against a median of 2.4 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Team Industries, Inc.
Kaukauna · 2025
278 401.62.4
Team Industries
Kaukauna · 2025
19 2012.84.3
Kaukauna location
Kaukauna · 2021
235 512.42.4

Included with any plan: 13 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 6 reports on file.

Jun 30, 2020, Kaukauna: Hospitalization · fractures · foot (feet), unspecified

An employee was using a paint brush to touch the side of a spool that another employee was loading onto a trailer using an overhead crane when the spool (12 feet long with a 12-inch diameter) caught another spool on the trailer. This caused the other spool, to fall off the trailer and strike the employee's left foot, fracturing it.

Aug 22, 2019, Kaukauna: Hospitalization · fractures · leg(s), unspecified

An employee was hydrostatically testing a pipe when the hydro plug was ejected, striking and breaking her leg. She was hospitalized.

Jul 10, 2018, Kaukauna: Hospitalization · cuts, lacerations · head, unspecified

An employee was operating a powered industrial vehicle (tug) when it took an abrupt turn. The employee lost balance and was thrown from the vehicle to the concrete surface, suffering a head laceration that required hospitalization.

Aug 23, 2016, Kaukauna: Hospitalization · cuts, lacerations · leg(s), unspecified

On August 23, 2016, an employee was welding a custom pipe when a gear or piece of the turn table failed and a pipe fell, crushing the employee's leg and lacerating a muscle.

Oct 8, 2015, Kaukauna: Amputation · amputations · finger(s), fingernail(s), unspecified

While straightening a piece of metal using the piranha press, an employee amputated part of a finger.

Feb 2, 2015, Kaukauna: Hospitalization · traumatic injuries and disorders, unspecified · nonclassifiable

Employee was hospitalized after he fell 10 to 11 feet from the top of an 11-foot ladder.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1000 · Air contaminants

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.107(e)(2)

(2) Quantity. The quantity of flammable liquids or liquids with a flashpoint greater than 199.4 °F (93 °C) kept in the vicinity of spraying operations shall be the minimum required for operations and should ordinarily not exceed a supply for 1 day or one shift. Bulk storage of portable containers of flammable liquids or liquids with a flashpoint greater than 199.4 °F (93 °C) shall be in a separate, constructed building detached from other important buildings or cut off in a standard manner.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.184 · Slings

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.24 · Fixed industrial stairs

29 CFR 1910.243 · Guarding of portable powered tools

29 CFR 1910.25 · Portable wood ladders

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.335 · Safeguards for personnel protection

29 CFR 1910.94 · Ventilation

29 CFR 1910.95 · Noise

Other fabricated pipe and pipe fitting manufacturing employers in Wisconsin

Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.