Teco Maintenance Corp has one OSHA inspection on record in New Jersey.

OSHA opened it on Feb 17, 2021, in Englewood.

From that inspection OSHA issued 3 citation items: 3 serious.

OSHA proposed $10,142 in penalties and the amount has not been reduced.

For context, across all staffing, cleaning and waste services employers the median penalty per cited inspection since 2015 is $2,208. Teco Maintenance Corp averages $10,142 over 1 cited inspection in that time.

Teco Maintenance Corp: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

New Jersey · latest 90 days of OSHA records

269employers cited

Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Jersey

Checking a subcontractor, a client or your own company? Watch Teco Maintenance Corp and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345152490 OPENED FEB 17, 2021Closed

Unprogrammed other · Partial · Safety · 15 employees at the site · Closed Jun 24, 2024

40 Nathaniel Pl, Englewood, NJ 07631 · Carpet and Upholstery Cleaning Services · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.36(d)(1) · Exit route design
Serious$3,901$3,901Aug 11, 2021Final
Citation 1, item 2
29 CFR 1910.37(a)(3) · Exit routes
Serious$3,901$3,901Aug 11, 2021Final
Citation 1, item 3
29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods
Serious$2,340$2,340Aug 11, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(g)(2)(ii)

(ii) Flexible cords may be used only in continuous lengths without splice or tap. Hard-service cord and junior hard-service cord No. 14 and larger may be repaired if spliced so that the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced.

29 CFR 1910.36 · Exit route design

29 CFR 1910.36(d)(1)

(d) An exit door must be unlocked. (1) Employees must be able to open an exit route door from the inside at all times without keys, tools, or special knowledge. A device such as a panic bar that locks only from the outside is permitted on exit discharge doors.

29 CFR 1910.37 · Exit routes

29 CFR 1910.37(a)(3)

(3) Exit routes must be free and unobstructed. No materials or equipment may be placed, either permanently or temporarily, within the exit route. The exit access must not go through a room that can be locked, such as a bathroom, to reach an exit or exit discharge, nor may it lead into a dead-end corridor. Stairs or a ramp must be provided where the exit route is not substantially level.