Inspection 343099792 OPENED APR 19, 2018Closed
502 N Hill Crest Drive, Shelbyville, TN 37160 · Heating Equipment (except Warm Air Furnaces) Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Shelbyville, Tennessee · Heating Equipment (except Warm Air Furnaces) Manufacturing · NAICS 333414
Since 2017, OSHA inspectors have visited Terry York in Tennessee 4 times.
The most recent inspection opened on Apr 19, 2018 after a complaint, in Shelbyville.
In all, OSHA issued 13 citation items: 6 serious and 7 other-than-serious.
The penalties, $2,900 in total, stand where OSHA first set them.
The rule cited most here is 1910.1200 (hazard communication), 4 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Terry York averages $967 across 3 cited inspections.
Tennessee · latest 90 days of OSHA records
344employers cited
Get notified the morning OSHA posts each new citation in Tennessee: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Tennessee
Checking a subcontractor, a client or your own company? Watch Terry York and get notified the morning OSHA posts a new citation for it.
Watch this company502 N Hill Crest Drive, Shelbyville, TN 37160 · Heating Equipment (except Warm Air Furnaces) Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
502 N Hill Crest Drive, Shelbyville, TN 37160 · Heating Equipment (except Warm Air Furnaces) Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.107(g)(2) · Spray painting and finishing |
Serious | $1,050 | $1,050 | Jan 19, 2018 | Final |
| Citation 1, item 2 29 CFR 1910.134(c)(2)(ii) · Respiratory protection |
Serious | $1,050 | $1,050 | Jan 19, 2018 | Final |
| Citation 2, item 1a 29 CFR 1910.1200(e)(1) · Hazard communication |
Other-than-serious | $150 | $150 | Jan 19, 2018 | Final |
| Citation 2, item 1b 29 CFR 1910.1200(h)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Jan 19, 2018 | Final |
| Citation 2, item 1c 29 CFR TDLWD RULE 800-01-09-.07(4) |
Other-than-serious | $0 | $0 | Jan 19, 2018 | Final |
502 N Hill Crest Drive, Shelbyville, TN 37160 · Heating Equipment (except Warm Air Furnaces) Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.303(g)(1) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Jan 11, 2018 | Final |
| Citation 1, item 2 29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Jan 11, 2018 | Final |
502 N Hill Crest Drive, Shelbyville, TN 37160 · Heating Equipment (except Warm Air Furnaces) Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.107(c)(5) · Spray painting and finishing |
Serious | $300 | $300 | Jun 27, 2017 | Final |
| Citation 1, item 1b 29 CFR 1910.107(g)(2) · Spray painting and finishing |
Serious | $0 | $0 | Jun 27, 2017 | Final |
| Citation 1, item 2a 29 CFR 1910.134(c)(2)(i) · Respiratory protection |
Serious | $350 | $350 | Jun 27, 2017 | Final |
| Citation 1, item 2b 29 CFR 1910.134(c)(2)(ii) · Respiratory protection |
Serious | $0 | $0 | Jun 27, 2017 | Final |
| Citation 2, item 1a 29 CFR 1910.1200(e)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Jun 27, 2017 | Final |
| Citation 2, item 1b 29 CFR 1910.1200(h)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Jun 27, 2017 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.107(c)(5)
(5) Combustible residues, areas. Unless specifically approved for locations containing both deposits of readily ignitable residue and explosive vapors, there shall be no electrical equipment in any spraying area, whereon deposits of combustible residues may readily accumulate, except wiring in rigid conduit or in boxes or fittings containing no taps, splices, or terminal connections.
29 CFR 1910.107(g)(2)
(2) Cleaning. All spraying areas shall be kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary. Scrapers, spuds, or other such tools used for cleaning purposes shall be of nonsparking material.
29 CFR 1910.1200(e)(1)
(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:
Alert subscribers get notified of each newly cited employer in Tennessee the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.