OSHA SearchOSHA records by employer

Terry York: OSHA inspections and violations

Shelbyville, Tennessee · Heating Equipment (except Warm Air Furnaces) Manufacturing · NAICS 333414

4inspections
13citation items
$2,900current penalties
Apr 19, 2018last inspection

Since 2017, OSHA inspectors have visited Terry York in Tennessee 4 times.

The most recent inspection opened on Apr 19, 2018 after a complaint, in Shelbyville.

In all, OSHA issued 13 citation items: 6 serious and 7 other-than-serious.

The penalties, $2,900 in total, stand where OSHA first set them.

The rule cited most here is 1910.1200 (hazard communication), 4 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Terry York averages $967 across 3 cited inspections.

Terry York: OSHA citation items per year, 2017 to 2018
Citation items per year, by inspection date.

Tennessee · latest 90 days of OSHA records

344employers cited

Get notified the morning OSHA posts each new citation in Tennessee: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Tennessee

Checking a subcontractor, a client or your own company? Watch Terry York and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343099792 OPENED APR 19, 2018Closed

Complaint · Partial · Safety · 4 employees at the site · Closed May 31, 2018

502 N Hill Crest Drive, Shelbyville, TN 37160 · Heating Equipment (except Warm Air Furnaces) Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342794427 OPENED NOV 28, 2017Closed

Complaint · Partial · Health · 6 employees at the site · Closed Sep 5, 2024

502 N Hill Crest Drive, Shelbyville, TN 37160 · Heating Equipment (except Warm Air Furnaces) Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.107(g)(2) · Spray painting and finishing
Serious$1,050$1,050Jan 19, 2018Final
Citation 1, item 2
29 CFR 1910.134(c)(2)(ii) · Respiratory protection
Serious$1,050$1,050Jan 19, 2018Final
Citation 2, item 1a
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$150$150Jan 19, 2018Final
Citation 2, item 1b
29 CFR 1910.1200(h)(1) · Hazard communication
Other-than-serious$0$0Jan 19, 2018Final
Citation 2, item 1c
29 CFR TDLWD RULE 800-01-09-.07(4)
Other-than-serious$0$0Jan 19, 2018Final

Inspection 342794708 OPENED NOV 28, 2017Closed

Complaint · Partial · Safety · 6 employees at the site · Closed Mar 21, 2018

502 N Hill Crest Drive, Shelbyville, TN 37160 · Heating Equipment (except Warm Air Furnaces) Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Other-than-serious$0$0Jan 11, 2018Final
Citation 1, item 2
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Jan 11, 2018Final

Inspection 342298445 OPENED MAY 4, 2017Closed

Complaint · Partial · Health · 7 employees at the site · Closed Sep 6, 2024

502 N Hill Crest Drive, Shelbyville, TN 37160 · Heating Equipment (except Warm Air Furnaces) Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.107(c)(5) · Spray painting and finishing
Serious$300$300Jun 27, 2017Final
Citation 1, item 1b
29 CFR 1910.107(g)(2) · Spray painting and finishing
Serious$0$0Jun 27, 2017Final
Citation 1, item 2a
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Serious$350$350Jun 27, 2017Final
Citation 1, item 2b
29 CFR 1910.134(c)(2)(ii) · Respiratory protection
Serious$0$0Jun 27, 2017Final
Citation 2, item 1a
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Jun 27, 2017Final
Citation 2, item 1b
29 CFR 1910.1200(h)(1) · Hazard communication
Other-than-serious$0$0Jun 27, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(c)(5)

(5) Combustible residues, areas. Unless specifically approved for locations containing both deposits of readily ignitable residue and explosive vapors, there shall be no electrical equipment in any spraying area, whereon deposits of combustible residues may readily accumulate, except wiring in rigid conduit or in boxes or fittings containing no taps, splices, or terminal connections.

29 CFR 1910.107(g)(2)

(2) Cleaning. All spraying areas shall be kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary. Scrapers, spuds, or other such tools used for cleaning purposes shall be of nonsparking material.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

Other heating equipment (except warm air furnaces) manufacturing employers in Tennessee

Alert subscribers get notified of each newly cited employer in Tennessee the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.