OSHA SearchOSHA records by employer

Texas Auger Boring, LLC: OSHA inspections and violations

San Antonio, Texas · Drilling Oil and Gas Wells · NAICS 213111

1inspections
3citation items
$7,743current penalties
Apr 12, 2024last inspection

OSHA inspectors have visited Texas Auger Boring, LLC in Texas one time.

It opened on Apr 12, 2024 as a planned inspection, in San Antonio.

In all, OSHA issued 3 citation items: 3 serious.

The proposed penalties came to $12,905; today they stand at $7,743, 40% less.

The rule cited most here is 1926.651 (excavations), 2 times.

Among mining and oil and gas employers, the typical cited inspection since 2015 ends with a $2,886 penalty. Texas Auger Boring, LLC averages $7,743 across 1 cited inspection.

Texas Auger Boring, LLC: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

391employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Texas Auger Boring, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347411902 OPENED APR 12, 2024Closed

Planned · Partial · Safety · 25 employees at the site · Closed Jun 25, 2024

410 And East Southcross, San Antonio, TX 78223 · Drilling Oil and Gas Wells · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$5,531$3,319Jun 10, 2024Final
Citation 1, item 2 Serious$3,687$2,212Jun 10, 2024Final
Citation 1, item 3
29 CFR 1926.651(k)(1) · Excavations
Serious$3,687$2,212Jun 10, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(i)

(b) Branch circuits—(1) Ground-fault protection—(i) General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(g)(1)(i)

(i) Where oxygen deficiency (atmospheres containing less than 19.5 percent oxygen) or a hazardous atmosphere exists or could reasonably be expected to exist, such as in excavations in landfill areas or excavations in areas where hazardous substances are stored nearby, the atmospheres in the excavation shall be tested before employees enter excavations greater than 4 feet (1.22 m) in depth.

29 CFR 1926.651(k)(1)

(k) Inspections. (1) Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated.

Other drilling oil and gas wells employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.