OSHA SearchOSHA records by employer

Texas Building Center: OSHA inspections and violations

Kingsland, Texas · Prefabricated Metal Building and Component Manufacturing · NAICS 332311

1inspections
4citation items
$1,440current penalties
Mar 26, 2015last inspection

OSHA inspectors have visited Texas Building Center in Texas one time.

It opened on Mar 26, 2015 after a complaint, in Kingsland.

In all, OSHA issued 4 citation items: 2 serious and 2 other-than-serious.

The proposed penalties came to $2,400; today they stand at $1,440, 40% less.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Texas Building Center averages $1,440 across 1 cited inspection.

Texas Building Center: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

393employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Texas Building Center and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340491810 OPENED MAR 26, 2015Closed

Complaint · Partial · Health · 5 employees at the site · Closed Jun 16, 2015

3201 Fm 1431, Kingsland, TX 78639 · Prefabricated Metal Building and Component Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.101(b) · Compressed gases (general requirements)
Serious$1,200$720Jun 2, 2015Final
Citation 1, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Serious$1,200$720Jun 2, 2015Final
Citation 2, item 1
29 CFR 1910.134(d)(1)(iii) · Respiratory protection
Other-than-serious$0$0Jun 2, 2015Final
Citation 2, item 2
29 CFR 1910.179(b)(5) · Overhead and gantry cranes
Other-than-serious$0$0Jun 2, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.101 · Compressed gases (general requirements)

29 CFR 1910.101(b)

(b) Compressed gases. The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in § 1910.6.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(d)(1)(iii)

(iii) The employer shall identify and evaluate the respiratory hazard(s) in the workplace; this evaluation shall include a reasonable estimate of employee exposures to respiratory hazard(s) and an identification of the contaminant's chemical state and physical form. Where the employer cannot identify or reasonably estimate the employee exposure, the employer shall consider the atmosphere to be IDLH.

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.179(b)(5)

(5) Rated load marking. The rated load of the crane shall be plainly marked on each side of the crane, and if the crane has more than one hoisting unit, each hoist shall have its rated load marked on it or its load block and this marking shall be clearly legible from the ground or floor.

29 CFR 1910.212 · Machine guarding

Other prefabricated metal building and component manufacturing employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.