OSHA SearchOSHA records by employer

Texas Premier Drywall Systems, LLC: OSHA inspections and violations

Kemah, Texas · Drywall and Insulation Contractors · NAICS 238310

5inspections
3citation items
$22,106current penalties
Oct 23, 2024last inspection

Texas Premier Drywall Systems, LLC has 5 OSHA inspections on record in Texas, the first in 2018.

OSHA's last visit started on Oct 23, 2024 as a planned inspection, in Cypress.

Across those inspections OSHA issued 3 citation items: 2 serious and 1 other-than-serious.

OSHA proposed $22,259 in penalties. After settlements and reviews the total is $22,106, down 1%.

Most often, OSHA cited 1926.453, aerial lifts (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Texas Premier Drywall Systems, LLC averages $11,053 over 2 cited inspections in that time.

Texas Premier Drywall Systems, LLC: OSHA citation items per year, 2018 to 2024
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

401employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Texas Premier Drywall Systems, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347840068 OPENED OCT 23, 2024Closed

Planned · Partial · Safety · 44 employees at the site · Closed Nov 14, 2024

22331 Fm 529, Cypress, TX 77433 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 346970353 OPENED SEP 12, 2023Closed

Unprogrammed other · Complete · Health · 6 employees at the site · Closed Oct 10, 2023

6901 Medical Center Drive, Orange, TX 77630 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 346378904 OPENED DEC 7, 2022Closed

Planned · Partial · Health · 44 employees at the site · Closed Jun 2, 2025

25615 Clay Rd., Katy, TX 77449 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$10,938$10,938Mar 24, 2023Final
Citation 1, item 2 Serious$10,938$10,938Mar 24, 2023Final

Inspection 343634580 OPENED NOV 29, 2018Closed

Unprogrammed other · Partial · Safety · 12 employees at the site · Closed Mar 8, 2019

1840 Williams Way, Richmond, TX 77469 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Other-than-serious$383$230Feb 14, 2019Final

Inspection 343521977 OPENED OCT 10, 2018Closed

Unprogrammed other · Partial · Safety · 44 employees at the site · Closed Oct 25, 2018

330 Marina Bay Dr. Stewart Elementary School, Kemah, TX 77565 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(2)(i)

(i) An employer may provide respirators at the request of employees or permit employees to use their own respirators, if the employer determines that such respirator use will not in itself create a hazard. If the employer determines that any voluntary respirator use is permissible, the employer shall provide the respirator users with the information contained in appendix D to this section (“Information for Employees Using Respirators When Not Required Under the Standard”); and

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.453(b)(2)(v)

(v) A body belt shall be worn and a lanyard attached to the boom or basket when working from an aerial lift.

29 CFR 1926.453(b)(2)(vii)

(vii) The brakes shall be set and when outriggers are used, they shall be positioned on pads or a solid surface. Wheel chocks shall be installed before using an aerial lift on an incline, provided they can be safely installed.

Other drywall and insulation contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.