Inspection 346925035 OPENED AUG 22, 2023Closed
744 Mcdermott Rushtown Rd, Mc Dermott, OH 45652 · Cut Stone and Stone Product Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Mc Dermott, Ohio · Cut Stone and Stone Product Manufacturing · NAICS 327991
The Briar Hill Stone Company has 5 OSHA inspections on record in Ohio, the first in 1973.
OSHA's last visit started on Aug 22, 2023 on a referral, in Mc Dermott.
Across those inspections OSHA issued 8 citation items: 4 serious, 1 repeat and 3 other-than-serious.
OSHA proposed $16,435 in penalties. After settlements and reviews the total is $8,435, down 49%.
Most often, OSHA cited 1910.303, electrical equipment, general requirements (2 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. The Briar Hill Stone Company averages $4,218 over 2 cited inspections in that time.
Ohio · latest 90 days of OSHA records
261employers cited
2 of them in the same industry
Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Ohio
Checking a subcontractor, a client or your own company? Watch The Briar Hill Stone Company and get notified the morning OSHA posts a new citation for it.
Watch this company744 Mcdermott Rushtown Rd, Mc Dermott, OH 45652 · Cut Stone and Stone Product Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
744 Mcdermott Rushtown Rd, Mc Dermott, OH 45652 · Cut Stone and Stone Product Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.303(b)(7)(i) · Electrical equipment, general requirements |
Repeat | $4,435 | $4,435 | Aug 8, 2018 | Final |
744 Mcdermott Rushtown Rd, Mc Dermott, OH 45652 · Cut Stone and Stone Product Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
744 Mcdermott Rushtown Rd, Mc Dermott, OH 45652 · Cut Stone and Stone Product Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.37(a)(3) · Exit routes |
Serious | $2,000 | $2,000 | May 13, 2016 | Final |
| Citation 1, item 2 29 CFR 1910.106(d)(4)(iii) · Flammable liquids |
Serious | $2,000 | $2,000 | May 13, 2016 | Final |
| Citation 1, item 3 29 CFR 1910.107(c)(6) · Spray painting and finishing |
Serious | $2,000 | $0 | May 13, 2016 | Final |
| Citation 1, item 4 29 CFR 1910.159(c)(2) · Automatic sprinkler systems |
Serious | $2,000 | $0 | May 13, 2016 | Final |
| Citation 1, item 5 29 CFR 1910.134(c)(1) · Respiratory protection |
Other-than-serious | $2,000 | $0 | May 13, 2016 | Final |
| Citation 1, item 6 29 CFR 1910.303(b)(7)(i) · Electrical equipment, general requirements |
Other-than-serious | $2,000 | $0 | May 13, 2016 | Final |
| Citation 1, item 7 29 CFR 1910.1200(f)(5)(ii) · Hazard communication |
Other-than-serious | $0 | $0 | May 13, 2016 | Final |
No Street Address, Glenmont, OH 44628 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.106(d)(4)(iii)
(iii) Wiring. Electrical wiring and equipment located in inside storage rooms used for Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be approved under subpart S of this part for Class I, Division 2 Hazardous Locations; for Category 3 flammable liquids with a flashpoint at or above 100 °F (37.8 °C) and Category 4 flammable liquids, shall be approved for general use.
29 CFR 1910.107(c)(6)
(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.
29 CFR 1910.1200(f)(5)(ii)
(ii) The label for bulk shipments of hazardous chemicals must be on the immediate container, transmitted with the shipping papers or the bills of lading, or, with the agreement of the receiving entity, transmitted by technological or electronic means so that it is immediately available to workers in printed form on the receiving end of shipment.
Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.