Since 1985, OSHA inspectors have visited The Burton Corporation in Vermont 9 times.
The most recent inspection opened on Jul 7, 2017, in Burlington.
In all, OSHA issued 64 citation items: 27 serious and 37 other-than-serious.
The proposed penalties came to $15,035; today they stand at $9,210, 39% less.
The rule cited most here is 1910.1200 (hazard communication), 9 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. The Burton Corporation averages $2,750 across 2 cited inspections.
The Burton Corporation also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
Vermont · latest 90 days of OSHA records
28employers cited
Get notified the morning OSHA posts each new citation in Vermont: the employer, the site address, the rules broken and the penalty.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Burlington site logged 3 recordable injuries or illnesses among about 437 workers: 0.8 per 100 full-time workers, against a median of 2.3 for its industry.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Burton Corporation
Burlington · 2025
437
3
0
0.8
2.3
Craigs - Burton Snowboards Corp
Burlington · 2025
24
0
0
0.0
2.3
Burton Snowboards Corporation 80
Burlington · 2017
358
4
2
1.3
2.3
Burton Snowboards Corporation 152
Burlington · 2017
40
0
0
0.0
2.3
Chill
Burlington · 2017
9
1
0
14.4
2.3
Retail College St
Burlington · 2017
7
0
0
0.0
2.3
Included with any plan: 5 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra
29 CFR 1910.106(d)(6)(iii)
(iii) Spill containment. The storage area shall be graded in a manner to divert possible spills away from buildings or other exposures or shall be surrounded by a curb at least 6 inches high. When curbs are used, provisions shall be made for draining of accumulations of ground or rain water or spills of flammable liquids. Drains shall terminate at a safe location and shall be accessible to operation under fire conditions.
29 CFR 1910.106(e)(6)(i)
(6) Sources of ignition—(i) General. Adequate precautions shall be taken to prevent the ignition of flammable vapors. Sources of ignition include but are not limited to open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat.
Alert subscribers get notified of each newly cited employer in Vermont the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.