OSHA SearchOSHA records by employer

The GC Broach Company: OSHA inspections and violations

Tulsa, Oklahoma · Plate Work Manufacturing · NAICS 332313

1inspections
5citation items
$6,761current penalties
Jan 31, 2018last inspection

OSHA has inspected The GC Broach Company once in Oklahoma.

The inspection began on Jan 31, 2018 as a planned inspection, in Tulsa.

That inspection ended with 5 citation items: 5 serious.

Penalties were first proposed at $11,269 and now stand at $6,761, 40% lower after settlements or reviews.

Spray painting and finishing comes up most often in these citations: 2 items under 1910.107.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and The GC Broach Company averages $6,761 (1 cited inspection).

The GC Broach Company: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Oklahoma · latest 90 days of OSHA records

54employers cited

Get notified the morning OSHA posts each new citation in Oklahoma: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oklahoma

Checking a subcontractor, a client or your own company? Watch The GC Broach Company and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342922176 OPENED JAN 31, 2018Closed

Planned · Complete · Safety · 60 employees at the site · Closed May 24, 2018

8199 E. 44th St., Tulsa, OK 74145 · Plate Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$3,298$1,979Mar 30, 2018Final
Citation 1, item 1b
29 CFR 1910.107(c)(6) · Spray painting and finishing
Serious$0$0Mar 30, 2018Final
Citation 1, item 1c
29 CFR 1910.107(g)(5) · Spray painting and finishing
Serious$0$0Mar 30, 2018Final
Citation 1, item 2
29 CFR 1910.140(d)(2)(ii) · Personal fall protection systems
Serious$3,298$1,979Mar 30, 2018Final
Citation 1, item 3
29 CFR 1910.212(a)(1) · Machine guarding
Serious$4,673$2,804Mar 30, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(6)(ii)

(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(c)(6)

(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.

29 CFR 1910.107(g)(5)

(5) Cleaning solvents. The use of solvents for cleaning operations shall be restricted to those having flashpoints not less than 100 °F.; however, for cleaning spray nozzles and auxiliary equipment, solvents having flashpoints not less than those normally used in spray operations may be used. Such cleaning shall be conducted inside spray booths and ventilating equipment operated during cleaning.

29 CFR 1910.140 · Personal fall protection systems

29 CFR 1910.212 · Machine guarding

Other plate work manufacturing employers in Oklahoma

Alert subscribers get notified of each newly cited employer in Oklahoma the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.