OSHA SearchOSHA records by employer

The LYNCH Company Inc: OSHA inspections and violations

Portland, Oregon · Plate Work Manufacturing · NAICS 332313

12inspections
48citation items
$5,823current penalties
Mar 6, 2024last inspection

Since 1972, OSHA inspectors have visited The LYNCH Company Inc in Oregon 12 times.

The most recent inspection opened on Mar 6, 2024 as a planned inspection, in Portland.

In all, OSHA issued 48 citation items: 27 serious and 21 other-than-serious.

The proposed penalties came to $6,303; today they stand at $5,823, 8% less.

The rule cited most here is 1910.212 (machine guarding), 6 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. The LYNCH Company Inc averages $1,158 across 3 cited inspections.

The LYNCH Company Inc also files yearly injury logs with OSHA, summarized below.

The LYNCH Company Inc: OSHA citation items per year, 1972 to 2024
Citation items per year, by inspection date.

Oregon · latest 90 days of OSHA records

383employers cited

Get notified the morning OSHA posts each new citation in Oregon: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oregon

Checking a subcontractor, a client or your own company? Watch The LYNCH Company Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347346801 OPENED MAR 6, 2024Closed

Planned · Complete · Safety · 36 employees at the site · Closed Sep 16, 2024

4706 Se 18th Ave, Portland, OR 97202 · Plate Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.212(a)(2) · Machine guarding
Serious$1,383$1,383Apr 10, 2024Final
Citation 1, item 1b
29 CFR 1910.212(a)(1) · Machine guarding
Serious$0$0Apr 10, 2024Final
Citation 2, item 2
29 CFR 1910.305(c)(4) · Electrical wiring methods
Other-than-serious$0$0Apr 10, 2024Final
Citation 2, item 3
29 CFR 1910.110(c)(5)(i)(i) · Storage and handling of liquefied petroleum gases
Other-than-serious$0$0Apr 10, 2024Final
Citation 2, item 4
29 CFR 1910.1200(f)(6)(ii) · Hazard communication
Other-than-serious$0$0Apr 10, 2024Final
Citation 2, item 5
29 CFR OAR 437-002-2101(2)
Other-than-serious$0$0Apr 10, 2024Final

Inspection 343963633 OPENED APR 18, 2019Closed

Planned · Complete · Safety · 50 employees at the site · Closed Sep 25, 2019

4706 Se 18th Ave, Portland, OR 97202 · Plate Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$180$180May 9, 2019Final
Citation 1, item 2a Serious$350$350May 9, 2019Final
Citation 1, item 2b Serious$0$0May 9, 2019Final
Citation 1, item 3
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$180$180May 9, 2019Final
Citation 2, item 4
29 CFR OAR 437-002-2253(9)(A)(K)
Other-than-serious$0$0May 9, 2019Final

Inspection 340896125 OPENED JUL 16, 2015Closed

Planned · Complete · Safety · 50 employees at the site · Closed Jan 13, 2016

4706 Se 18th Ave, Portland, OR 97202 · Plate Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$180$180Sep 8, 2015Final
Citation 1, item 2
29 CFR OAR 437-002-2101(2)
Serious$300$300Sep 8, 2015Final
Citation 1, item 3 Serious$180$180Sep 8, 2015Final
Citation 1, item 4
29 CFR OAR 437-002-0221(13)(A)-1
Serious$180$180Sep 8, 2015Final
Citation 1, item 5
29 CFR 1910.101(a) · Compressed gases (general requirements)
Serious$180$180Sep 8, 2015Final
Citation 1, item 6
29 CFR 1910.22(d)(1) · General requirements
Serious$180$180Sep 8, 2015Final
Citation 1, item 7
29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks
Serious$180$180Sep 8, 2015Final
Citation 2, item 8
29 CFR 1910.179(b)(5) · Overhead and gantry cranes
Other-than-serious$0$0Sep 8, 2015Final
Citation 2, item 9
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Sep 8, 2015Final

Inspection 313957102 OPENED FEB 9, 2010Closed

Referral · Partial · Health · 60 employees at the site · Closed Oct 27, 2010

4706 Se 18th Ave, Portland, OR 97202 · Plate Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(k)(6) · Respiratory protection
Other-than-serious$0$0May 3, 2010Closed
Citation 1, item 2
29 CFR 1910.134(h)(2)(i) · Respiratory protection
Other-than-serious$0$0May 3, 2010Closed

Inspection 313954398 OPENED DEC 29, 2009Closed

Planned · Complete · Safety · 54 employees at the site · Closed Jun 4, 2010

4706 Se 18th, Portland, OR 97202 · Plate Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.253(b)(4)(i) · Gas welding and cutting
Serious$105$105Feb 8, 2010Closed
Citation 1, item 2
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$210$210Feb 8, 2010Closed
Citation 1, item 3
29 CFR 1910.219(f)(1) · Belts, pulleys and power-transmission parts
Serious$105$105Feb 8, 2010Closed
Citation 1, item 4
29 CFR 1910.219(b)(1) · Belts, pulleys and power-transmission parts
Serious$105$105Feb 8, 2010Closed
Citation 1, item 5
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$195$195Feb 8, 2010Closed
Citation 2, item 6
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Other-than-serious$0$0Feb 8, 2010Closed
Citation 2, item 7
29 CFR 1910.212(a)(1) · Machine guarding
Other-than-serious$0$0Feb 8, 2010Closed
Citation 2, item 8
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Other-than-serious$0$0Feb 8, 2010Closed

Inspection 309277754 OPENED OCT 19, 2005Closed

Planned · Complete · Safety · 65 employees at the site · Closed Jun 14, 2006

4706 Se 18th, Portland, OR 97202 · Plate Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$175$175Nov 3, 2005Closed
Citation 1, item 2
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$175$175Nov 3, 2005Closed
Citation 1, item 3
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$195$195Nov 3, 2005Closed
Citation 2, item 4 Other-than-serious$500$500Nov 3, 2005Closed
Citation 2, item 5
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Other-than-serious$0$0Nov 3, 2005Closed
Citation 2, item 6
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0Nov 3, 2005Closed
Citation 2, item 7 Other-than-serious$0$0Nov 3, 2005Closed

Inspection 304222300 OPENED MAR 29, 2001Closed

Planned · Complete · Safety · 35 employees at the site · Closed Feb 15, 2002

4706 Se 18th Ave, Portland, OR 97202 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$210$0May 1, 2001Final

Inspection 303358733 OPENED DEC 7, 2000Closed

Planned · No inspection · Safety · 22 employees at the site · Closed Dec 7, 2000

4706 Se 18th Ave, Portland, OR 97202 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

4 older inspections

Inspection 126692235 OPENED AUG 31, 1995Closed

Referral · Partial · Health · 30 employees at the site · Closed Apr 29, 1998

401 Ne Ainsworth, Portland, OR 97211 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(d)(2)(ii) · Respiratory protection
Other-than-serious$270$0Feb 1, 1996Final

Inspection 115760332 OPENED JUN 29, 1992Closed

Planned · Complete · Safety · 25 employees at the site · Closed Nov 6, 1992

401 Ne Ainsworth, Portland, OR 97211 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$105$105Jul 30, 1992Final
Citation 1, item 2
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$150$150Jul 30, 1992Final
Citation 1, item 4
29 CFR 1910.217(d)(9)(iv) · Mechanical power presses
Serious$75$75Jul 30, 1992Final
Citation 1, item 5
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$75$75Jul 30, 1992Final
Citation 1, item 6 Serious$75$75Jul 30, 1992Final
Citation 1, item 7
29 CFR 1910.217(c)(2)(i) · Mechanical power presses
Serious$105$105Jul 30, 1992Final
Citation 2, item 8 Other-than-serious$0$0Jul 30, 1992Final
Citation 2, item 9
29 CFR 7560165
Other-than-serious$0$0Jul 30, 1992Final
Citation 2, item 10 Other-than-serious$0$0Jul 30, 1992Final

Inspection 218450997 OPENED AUG 17, 1982Closed

Planned · Complete · Health · 13 employees at the site · Closed Aug 25, 1982

6000 N E Union Ave, Portland, OR 97211 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 218379733 OPENED DEC 12, 1972Closed

Planned · Complete · Safety · 19 employees at the site · Closed Mar 10, 1984

6000 Ne Union Ave, Portland, OR 97211 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Portland site logged 1 recordable injury or illness among about 33 workers: 3.3 per 100 full-time workers, against a median of 3.6 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
The Lynch Company, Inc.
Portland · 2025
33 103.33.6

Included with any plan: 7 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.101 · Compressed gases (general requirements)

29 CFR 1910.101(a)

(a) Inspection of compressed gas cylinders. Each employer shall determine that compressed gas cylinders under his control are in a safe condition to the extent that this can be determined by visual inspection. Visual and other inspections shall be conducted as prescribed in the Hazardous Materials Regulations of the Department of Transportation (49 CFR parts 171-179 and 14 CFR part 103). Where those regulations are not applicable, visual and other inspections shall be conducted in accordance with Compressed Gas Association Pamphlets C-6-1968 and C-8-1962, which is incorporated by reference as specified in § 1910.6.

29 CFR 1910.110 · Storage and handling of liquefied petroleum gases

29 CFR 1910.110(c)(5)(i)(i)

(ii) Containers having a maximum water capacity of 2 1/2 pounds (nominal 1 pound LP-Gas capacity) are permitted to be used inside of buildings as part of approved self-contained hand torch assemblies or similar appliances.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(f)(6)(ii)

(ii) Product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals, and which, in conjunction with the other information immediately available to employees under the hazard communication program, will provide employees with the specific information regarding the physical and health hazards of the hazardous chemical.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.184 · Slings

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.217 · Mechanical power presses

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · General requirements

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 7010.7002

29 CFR 7020.2280

29 CFR 7020.2420

29 CFR 7020.2900

29 CFR 7890.102

29 CFR 7890.550

Other plate work manufacturing employers in Oregon

Alert subscribers get notified of each newly cited employer in Oregon the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.