Colorado Springs, Colorado · Prefabricated Wood Building Manufacturing · NAICS 321992

2inspections
10citation items
$6,223current penalties
Jan 29, 2019last inspection

Since 2014, OSHA inspectors have visited The Shed Yard, Inc in Colorado 2 times.

The most recent inspection opened on Jan 29, 2019 after a complaint, in Penrose.

In all, OSHA issued 10 citation items: 8 serious and 2 other-than-serious.

The proposed penalties came to $6,905; today they stand at $6,223, 10% less.

The rule cited most here is 1910.305 (electrical wiring methods), 3 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. The Shed Yard, Inc averages $1,023 across 1 cited inspection.

The Shed Yard, Inc: OSHA citation items per year, 2014 to 2019
Citation items per year, by inspection date.

Colorado · latest 90 days of OSHA records

136employers cited

Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Colorado

Checking a subcontractor, a client or your own company? Watch The Shed Yard, Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343746590 OPENED JAN 29, 2019Closed

Complaint · Partial · Safety · 9 employees at the site · Closed Feb 13, 2019

102 Shoop Drive, Penrose, CO 81240 · Prefabricated Wood Building Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.28(b)(1)(i) · Fall protection in general industry
Serious$1,705$1,023Feb 1, 2019Final

Inspection 339539280 OPENED JAN 7, 2014Closed

Complaint · Partial · Safety · 9 employees at the site · Closed Apr 2, 2015

2108 Victor Place, Colorado Springs, CO 80905 · Prefabricated Wood Building Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$2,000$2,000Mar 7, 2014Final
Citation 1, item 2a
29 CFR 1910.213(c)(1) · Woodworking machinery
Serious$2,000$2,000Mar 7, 2014Final
Citation 1, item 2b
29 CFR 1910.213(c)(2) · Woodworking machinery
Serious$0$0Mar 7, 2014Final
Citation 1, item 2c
29 CFR 1910.213(c)(3) · Woodworking machinery
Serious$0$0Mar 7, 2014Final
Citation 1, item 3a
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Serious$1,200$1,200Mar 7, 2014Final
Citation 1, item 3b
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$0$0Mar 7, 2014Final
Citation 1, item 3c
29 CFR 1910.334(a)(3)(i) · Using electrical equipment
Serious$0$0Mar 7, 2014Final
Citation 2, item 1
29 CFR 1910.178(l)(6) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Mar 7, 2014Final
Citation 2, item 2
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Other-than-serious$0$0Mar 7, 2014Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.178(l)(6)

(6) Certification. The employer shall certify that each operator has been trained and evaluated as required by this paragraph (l). The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation.

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.213(c)(1)

(c) Hand-fed ripsaws. (1) Each circular hand-fed ripsaw shall be guarded by a hood which shall completely enclose that portion of the saw above the table and that portion of the saw above the material being cut. The hood and mounting shall be arranged so that the hood will automatically adjust itself to the thickness of and remain in contact with the material being cut but it shall not offer any considerable resistance to insertion of material to saw or to passage of the material being sawed. The hood shall be made of adequate strength to resist blows and strains incidental to reasonable operation, adjusting, and handling, and shall be so designed as to protect the operator from flying splinters and broken saw teeth. It shall be made of material that is soft enough so that it will be unlikely to cause tooth breakage. The hood shall be so mounted as to insure that its operation will be po

29 CFR 1910.213(c)(2)

(2) Each hand-fed circular ripsaw shall be furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator. The spreader shall be made of hard tempered steel, or its equivalent, and shall be thinner than the saw kerf. It shall be of sufficient width to provide adequate stiffness or rigidity to resist any reasonable side thrust or blow tending to bend or throw it out of position. The spreader shall be attached so that it will remain in true alignment with the saw even when either the saw or table is tilted. The provision of a spreader in connection with grooving, dadoing, or rabbeting is not required. On the completion of such operations, the spreader shall be immediately replaced.

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.28 · Fall protection in general industry

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

Other prefabricated wood building manufacturing employers in Colorado

Alert subscribers get notified of each newly cited employer in Colorado the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.