Inspection 346174485 OPENED AUG 24, 2022Closed
32 Seabreeze Avenue, Milford, CT 06460 · Electric Bulk Power Transmission and Control · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Bridgeport, Connecticut · Electric Bulk Power Transmission and Control · NAICS 221121
OSHA has inspected The United Illuminating Company 27 times in Connecticut since 1975.
The latest one began on Aug 24, 2022 on a referral, in Milford.
Those inspections ended with 21 citation items: 9 serious and 12 other-than-serious.
Penalties were first proposed at $52,327 and now stand at $37,539, 28% lower after settlements or reviews.
Electric power generation, transmission, and distribution comes up most often in these citations: 5 items under 1910.269.
How that compares: the median penalty per cited inspection for utility employers since 2015 is $0, and The United Illuminating Company averages $8,751 (2 cited inspections).
1 inspection on this page followed a fatal incident.
The United Illuminating Company also files yearly injury logs with OSHA, summarized below.
It reported 1 severe injury to OSHA since 2015.
Connecticut · latest 90 days of OSHA records
84employers cited
Get notified the morning OSHA posts each new citation in Connecticut: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Connecticut
Checking a subcontractor, a client or your own company? Watch The United Illuminating Company and get notified the morning OSHA posts a new citation for it.
Watch this company32 Seabreeze Avenue, Milford, CT 06460 · Electric Bulk Power Transmission and Control · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Main Street And Olivia Street, Derby, CT 06418 · Electric Bulk Power Transmission and Control · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.950(b)(7) · Electric Power Transmission and Distribution: general |
Serious | $14,502 | $8,701 | Aug 25, 2022 | Final |
100 Marsh Hill Road, Orange, CT 06477 · Electric Bulk Power Transmission and Control · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
550 Boston Post Rd., Orange, CT 06477 · Electric Bulk Power Transmission and Control · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.269(l)(8)(v) · Electric power generation, transmission, and distribution |
Serious | $12,675 | $8,800 | Jun 1, 2017 | Final |
| Citation 1, item 1b 29 CFR 1910.269(a)(2)(i)(a) · Electric power generation, transmission, and distribution |
Other-than-serious | $0 | $0 | Jun 1, 2017 | Final |
State State Near Blatchley Avenue, New Haven, CT 06513 · Electric Bulk Power Transmission and Control · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1239 Main Street, Bridgeport, CT 06604 · Electric Bulk Power Transmission and Control · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.269(l)(4) · Electric power generation, transmission, and distribution |
Other-than-serious | $0 | $0 | Oct 15, 2012 | Final |
Campbell Ave., West Haven, CT 06516 · Electric Bulk Power Transmission and Control · OSHA's record · Phone and website on Google Maps
Incident on Feb 7, 2011: Burn - electrical fault in overhead power line
A power line worker was using a hydraulic, metal-cased drill with an auger bit t o drill a hole for an insulator at the top of a utility pole. The utility pole s upported a 2,700-volt overhead power line. The drill body contacted one conducto r and the tip of the bit contacted another conductor, causing an electrical faul t. The ensuing electric arc burned the employee. He was hospitalized with first- and second-degree burns to his face and neck.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.269(l)(2) · Electric power generation, transmission, and distribution |
Other-than-serious | $7,000 | $7,000 | Apr 15, 2011 | Closed |
35 Whalley Avenue, New Haven, CT 06511 · Electric Bulk Power Transmission and Control · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1904.32(b)(6) · Yearly injury summary |
Other-than-serious | $1,000 | $1,000 | May 12, 2009 | Closed |
510 River Rd, Shelton, CT 06484 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
200 Main St., Derby, CT 06418 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.850(c) · Preparatory operations |
Serious | $1,875 | $938 | Nov 14, 2006 | Closed |
801 Bridgeport Avenue, Shelton, CT 06484 · Electric Bulk Power Transmission and Control · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Corner Of Boston Post Road & East Town Road, Milford, CT 06460 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
801 Bridgeport Avenue, Shelton, CT 06484 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
Incident on Jul 11, 2003 (fatal): Employee is killed, two injured in electrical explosion
On July 11, 2003, Employees #1, #2 and #3 were assessing a work order to replace a damaged wire within the cage of a reactors housing. They suffered severe burn s after three lightning arresters connected to reactors exploded. Employee #1 la ter died on July 23, 2003 as a result of injuries suffered from the accident. Em ployees #2 and #3 were hospitalized and treated for burns.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements |
Serious | $5,000 | $3,500 | Nov 17, 2003 | Closed |
| Citation 1, item 2 29 CFR 1910.269(l)(6)(iii) · Electric power generation, transmission, and distribution |
Serious | $5,000 | $3,500 | Nov 17, 2003 | Closed |
| Citation 1, item 3 29 CFR 1910.132(e) · Personal protective equipment, general requirements |
Serious | $1,500 | $1,500 | Nov 17, 2003 | Closed |
10 Henry Street, Bridgeport, CT 06604 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
10 Henry Street, Bridgeport, CT 06604 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
10 Henry Street, Bridgeport, CT 06604 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Across From 360 Fairfield Avenue, Bridgeport, CT 06604 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
East Main And Putnam Streets, Bridgeport, CT 06608 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.200(g)(2) · Accident prevention signs and tags |
Serious | $1,875 | $1,200 | Jul 2, 1991 | Closed |
510 Grand Aveue, New Haven, CT 06513 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
10 Henry Street, Bridgeport, CT 06604 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
10 Henry St, Bridgeport, CT 06604 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.303(c)(2) · Abrasive wheels and tools |
Other-than-serious | $0 | $0 | Jan 30, 1985 | Closed |
| Citation 1, item 2 29 CFR 1926.303(c)(5) · Abrasive wheels and tools |
Other-than-serious | $0 | $0 | Jan 30, 1985 | Closed |
| Citation 1, item 3 29 CFR 1926.400(a) · Introduction |
Other-than-serious | $0 | $0 | Jan 30, 1985 | Closed |
| Citation 1, item 4 29 CFR 1926.401(c) · [Reserved] |
Other-than-serious | $0 | $0 | Jan 30, 1985 | Closed |
| Citation 1, item 5 29 CFR 1926.401(j)(1) · [Reserved] |
Other-than-serious | $0 | $0 | Nov 5, 1984 | Closed |
| Citation 1, item 6 29 CFR 1926.402(a)(8) · Applicability |
Other-than-serious | $0 | $0 | Nov 5, 1984 | Closed |
| Citation 1, item 7 29 CFR 1926.500(b)(1) · Scope, application, and definitions applicable to this subpart |
Other-than-serious | $0 | $0 | Nov 5, 1984 | Closed |
510 Grand Ave, New Haven, CT 06513 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
3750 Broadbridg Ave, Stratford, CT 06497 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.953(d) · Enclosed spaces |
Other-than-serious | $0 | $0 | Oct 12, 1983 | Closed |
Orange Center Rd & Meetinghous, Orange, CT 06477 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.950(c)(1) · Electric Power Transmission and Distribution: general |
Serious | $900 | $900 | Dec 18, 1981 | Closed |
Centerville Substation, Hamden, CT 06514 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Marne St, Hamden, CT 06514 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.950(c)(1) · Electric Power Transmission and Distribution: general |
Serious | $1,000 | $500 | Jun 7, 1978 | Contested |
1 Waterfront Street, New Haven, CT 06506 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2024, the Orange site logged 9 recordable injuries or illnesses among about 622 workers: 1.5 per 100 full-time workers, against a median of 1.0 for its industry. Those cases cost 87 days away from work.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| United Illuminating Orange · 2024 | 622 | 9 | 4 | 1.5 | 1.0 |
Included with any plan: 5 more yearly logs from these sites, back to 2019, with each site's average rate over its latest three years. Already a subscriber? Sign in.
See plansEmployers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.
Jan 1, 2022, Orange: Hospitalization · internal injuries to organs and blood vessels of the trunk · chest, except internal location of diseases or disorders
On Saturday, January 1, 2022, an employee was injured after being struck by the butt end of a utility pole that was being lifted from a pile of poles in the yard. The employee had climbed up onto a pile of poles in order to set the tongs from the derrick onto a pole for picking. The employee set the tongs in the approximate middle of the pole for weight balance and came down off of the pile. The…
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1904.32(b)(6)
(6) When do I have to post the annual summary? You must post the summary no later than February 1 of the year following the year covered by the records and keep the posting in place until April 30.
29 CFR 1910.132(d)(1)
(d) Hazard assessment and equipment selection. (1) The employer shall assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE). If such hazards are present, or likely to be present, the employer shall:
29 CFR 1910.132(e)
(e) Defective and damaged equipment. Defective or damaged personal protective equipment shall not be used.
Alert subscribers get notified of each newly cited employer in Connecticut the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.