OSHA SearchOSHA records by employer

Thueson Masonry, Inc.: OSHA inspections and violations

Salt Lake City, Utah · Masonry Contractors · NAICS 238140

3inspections
13citation items
$2,125current penalties
Apr 13, 2016last inspection

Since 2001, OSHA inspectors have visited Thueson Masonry, Inc. in Utah 3 times.

The most recent inspection opened on Apr 13, 2016 after an accident, in West Jordan.

In all, OSHA issued 13 citation items: 12 serious and 1 other-than-serious.

The proposed penalties came to $7,250; today they stand at $2,125, 71% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 8 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Thueson Masonry, Inc. averages $500 across 1 cited inspection.

Thueson Masonry, Inc.: OSHA citation items per year, 2001 to 2016
Citation items per year, by inspection date.

Utah · latest 90 days of OSHA records

73employers cited

Get notified the morning OSHA posts each new citation in Utah: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Utah

Checking a subcontractor, a client or your own company? Watch Thueson Masonry, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341405520 OPENED APR 13, 2016Closed

Accident · Partial · Safety · 8 employees at the site · Closed Aug 19, 2016

3354 W 8640 S, West Jordan, UT 84088 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR UAC R614-1-5.C.1
Other-than-serious$500$500May 16, 2016Final

Inspection 312404551 OPENED AUG 6, 2008Closed

Planned · Partial · Safety · 5 employees at the site · Closed Jan 6, 2009

Wild Horse Running Estate Lot 1205, Layton, UT 84041 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$1,500$125Sep 2, 2008Closed
Citation 1, item 1b
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$0$0Sep 2, 2008Closed
Citation 1, item 1c
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Sep 2, 2008Closed
Citation 1, item 2
29 CFR 1926.454(a) · Scaffold training
Serious$1,500$125Sep 2, 2008Closed

Inspection 304407752 OPENED APR 4, 2001Closed

Planned · Complete · Safety · 6 employees at the site · Closed Jun 30, 2005

3121 W Directors Row, Salt Lake City, UT 84104 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$1,250$425May 23, 2001Closed
Citation 1, item 1b
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0May 23, 2001Closed
Citation 1, item 1c
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0May 23, 2001Closed
Citation 1, item 1d
29 CFR 1926.451(h)(1) · Scaffolds, general requirements
Serious$0$0May 23, 2001Closed
Citation 1, item 2a
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$1,250$425May 23, 2001Closed
Citation 1, item 2b
29 CFR 1926.454(a) · Scaffold training
Serious$0$0May 23, 2001Closed
Citation 1, item 3a
29 CFR 1926.602(c)(1)(vi) · Earthmovers and forklifts in construction
Serious$1,250$525May 23, 2001Closed
Citation 1, item 3b
29 CFR 1910.178(l)(1) · Forklifts and other powered industrial trucks
Serious$0$0May 23, 2001Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.454 · Scaffold training

29 CFR 1926.602 · Earthmovers and forklifts in construction

Other masonry contractors employers in Utah

Alert subscribers get notified of each newly cited employer in Utah the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.