OSHA SearchOSHA records by employer

Tim Plastics, Inc.: OSHA inspections and violations

North East, Maryland · Plastics Bottle Manufacturing · NAICS 326160

6inspections
42citation items
$8,515current penalties
May 8, 2023last inspection

Since 1991, OSHA inspectors have visited Tim Plastics, Inc. in Maryland 6 times.

The most recent inspection opened on May 8, 2023 after a complaint, in North East.

In all, OSHA issued 42 citation items: 12 serious, 1 repeat and 29 other-than-serious.

The proposed penalties came to $12,050; today they stand at $8,515, 29% less.

The rule cited most here is 1910.147 (lockout/tagout), 14 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. Tim Plastics, Inc. averages $1,715 across 1 cited inspection.

Tim Plastics, Inc. also files yearly injury logs with OSHA, summarized below.

Tim Plastics, Inc.: OSHA citation items per year, 1991 to 2023
Citation items per year, by inspection date.

Want to know if OSHA cites Tim Plastics, Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 346689540 OPENED MAY 8, 2023Closed

Complaint · Complete · Safety · 20 employees at the site · Closed Sep 20, 2023

102 Peninsula Drive, North East, MD 21901 · Plastics Material and Resin Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$2,450$1,715Jul 21, 2023Final
Citation 1, item 1b
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$0$0Jul 21, 2023Final
Citation 1, item 1c
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$0$0Jul 21, 2023Final
Citation 2, item 1
29 CFR 1910.37(a)(3) · Exit routes
Other-than-serious$0$0Jul 21, 2023Final
Citation 2, item 2
29 CFR 1910.147(c)(6)(ii) · Lockout/tagout
Other-than-serious$0$0Jul 21, 2023Final
Citation 2, item 3
29 CFR 1910.147(c)(7)(iv) · Lockout/tagout
Other-than-serious$0$0Jul 21, 2023Final
Citation 2, item 4
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0Jul 21, 2023Final
Citation 2, item 5
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Other-than-serious$0$0Jul 21, 2023Final
Citation 2, item 6
29 CFR 1910.178(l)(6) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Jul 21, 2023Final
Citation 2, item 7
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Jul 21, 2023Final
Citation 2, item 8
29 CFR 1910.1200(g)(8) · Hazard communication
Other-than-serious$0$0Jul 21, 2023Final

Inspection 316890557 OPENED JAN 22, 2013Closed

Complaint · Partial · Safety · 33 employees at the site · Closed Jan 22, 2013

97 North Leslie Road, North East, MD 21901 · Plastics Bottle Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 304457237 OPENED MAY 7, 2001Closed

Planned · Complete · Health · 20 employees at the site · Closed Aug 24, 2001

97 North Leslie Road, North East, MD 21901 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0Jun 20, 2001Closed
Citation 1, item 2
29 CFR 1910.147(c)(6)(ii) · Lockout/tagout
Other-than-serious$0$0Jun 20, 2001Closed
Citation 1, item 3
29 CFR 1910.147(c)(7)(iv) · Lockout/tagout
Other-than-serious$0$0Jun 20, 2001Closed
Citation 1, item 4
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Jun 20, 2001Closed
Citation 1, item 5
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0Jun 20, 2001Closed
Citation 1, item 6
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Jun 20, 2001Closed
Citation 1, item 7
29 CFR 50405 B01
Other-than-serious$0$0Jun 20, 2001Closed
Citation 1, item 8
29 CFR 50406 A01
Other-than-serious$0$0Jun 20, 2001Closed
Citation 1, item 9 Other-than-serious$0$0Jun 20, 2001Closed

Inspection 302799903 OPENED JUL 7, 1999Closed

Complaint · Partial · Safety · 21 employees at the site · Closed Nov 30, 1999

97 North Leslie Road, North East, MD 21901 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Repeat$1,000$1,000Aug 13, 1999Closed
Citation 2, item 1a
29 CFR 1910.106(e)(2)(iii) · Flammable liquids
Serious$600$600Aug 13, 1999Closed
Citation 2, item 1b
29 CFR 1910.106(e)(2)(ivd) · Flammable liquids
Serious$0$0Aug 13, 1999Closed
Citation 2, item 1c
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$0$0Aug 13, 1999Closed
Citation 3, item 1
29 CFR 1910.157(g)(1) · Portable fire extinguishers
Other-than-serious$0$0Aug 13, 1999Closed
Citation 4, item 1
29 CFR 1910.305(b)(2) · Electrical wiring methods
Serious$600$600Aug 13, 1999Closed
Citation 5, item 1
29 CFR 1910.1200(f)(5)(ii) · Hazard communication
Serious$400$400Aug 13, 1999Closed
Citation 6, item 1
29 CFR 1910.23(d)(1)(iv) · Guarding floor and wall openings and holes
Other-than-serious$0$0Aug 13, 1999Closed
Citation 6, item 2
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Aug 13, 1999Closed
Citation 6, item 3
29 CFR 1910.132(f)(4) · Personal protective equipment, general requirements
Other-than-serious$0$0Aug 13, 1999Closed
Citation 6, item 4
29 CFR 1910.147(c)(4)(ii) · Lockout/tagout
Other-than-serious$0$0Aug 13, 1999Closed
Citation 6, item 5
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Other-than-serious$0$0Aug 13, 1999Closed
Citation 6, item 6
29 CFR 1910.303(f) · Electrical equipment, general requirements
Other-than-serious$0$0Aug 13, 1999Closed
Citation 6, item 7
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Aug 13, 1999Closed
Citation 6, item 8
29 CFR 1910.334(a)(2)(ii) · Using electrical equipment
Other-than-serious$0$0Aug 13, 1999Closed
Citation 6, item 9 Other-than-serious$0$0Aug 13, 1999Closed
Citation 6, item 10 Other-than-serious$0$0Aug 13, 1999Closed

Inspection 300686532 OPENED JUN 25, 1997Closed

Accident · Partial · Safety · 25 employees at the site · Closed Oct 22, 1997

97 North Leslie Road, North East, MD 21901 · OSHA's record · Phone and website on Google Maps

Incident on Jun 25, 1997: Employee's hand injured when caught in blow molding machine

At 2:50 a.m. on June 25, 1997, Employee #1 and a coworker were troubleshooting a n injection blow molding machine. The safety guards were removed by the coworker , who noticed that the Parison mold clamping pressure was too low. Employee #1 t old the coworker that he was going to the back of the machine to clean off the P arison mold, but the coworker said that would not solve the problem. Meanwhile, the coworker was checking the clamping pressure. He turned the switch that close d the mold just as Employee's hand was in between the two mold plates. Employee #1 sustained an injury to his right hand was transported to Union Memorial Hospi tal for treatment. The company had no energy control procedures in place.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$1,750$1,050Aug 4, 1997Closed
Citation 1, item 2
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$1,750$1,050Aug 4, 1997Closed
Citation 1, item 3
29 CFR 1910.147(c)(5)(i) · Lockout/tagout
Serious$1,750$1,050Aug 4, 1997Closed
Citation 1, item 4
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$1,750$1,050Aug 4, 1997Closed

Inspection 104354626 OPENED FEB 11, 1991Closed

Planned · Complete · Safety · 7 employees at the site · Closed Mar 26, 1991

97 N. Leslie Rd, Northeast, MD 21901 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.151(c) · First aid and eyewash
Other-than-serious$0$0Feb 28, 1991Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2022, the North East site logged 0 recordable injuries or illnesses among about 156 workers: 0.0 per 100 full-time workers, against a median of 2.6 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Tim Plastics Inc
North East · 2022
156 000.02.6

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 0912.2102

29 CFR 0912.2106

29 CFR 0912.2303

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(2)(iii)

(iii) Separation and protection. Areas in which flammable liquids are transferred from one tank or container to another container shall be separated from other operations in the building by adequate distance or by construction having adequate fire resistance. Drainage or other means shall be provided to control spills. Adequate natural or mechanical ventilation shall be provided.

29 CFR 1910.106(e)(2)(ivd)

(iv) Handling liquids at point of final use. (a) Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be kept in covered containers when not actually in use.

29 CFR 1910.106(e)(6)(ii)

(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.37 · Exit routes