OSHA SearchOSHA records by employer

Timberland Drywall: OSHA inspections and violations

Portland, Maine · Drywall and Insulation Contractors · NAICS 238310

9inspections
13citation items
$6,863current penalties
Jul 13, 2018last inspection

OSHA has inspected Timberland Drywall 9 times in Maine since 2001.

The latest one began on Jul 13, 2018, in Portland.

Those inspections ended with 13 citation items: 10 serious, 1 repeat and 2 other-than-serious.

Penalties were first proposed at $23,734 and now stand at $6,863, 71% lower after settlements or reviews.

Ground-fault protection on job sites comes up most often in these citations: 3 items under 1926.404.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Timberland Drywall averages $0 (1 cited inspection).

Timberland Drywall: OSHA citation items per year, 2001 to 2018
Citation items per year, by inspection date.

Maine · latest 90 days of OSHA records

34employers cited

Get notified the morning OSHA posts each new citation in Maine: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maine

Checking a subcontractor, a client or your own company? Watch Timberland Drywall and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343299160 OPENED JUL 13, 2018Closed

Unprogrammed other · Complete · Safety · 5 employees at the site · Closed Oct 4, 2018

230 Commercial Street, Portland, ME 04101 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.20(b)(2) · Construction safety programs
Other-than-serious$6,467$0Jul 31, 2018Final
Citation 1, item 2
29 CFR 1926.501(b)(14) · Fall protection in construction
Other-than-serious$6,467$0Jul 31, 2018Final

Inspection 339101503 OPENED JUN 3, 2013Closed

Unprogrammed other · Complete · Safety · 3 employees at the site · Closed Jun 24, 2013

364 Maine Mall Road, Portland, ME 04106 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$1,600$800Jun 6, 2013Final

Inspection 112520663 OPENED AUG 5, 2008Closed

Planned · Complete · Safety · 10 employees at the site · Closed Aug 28, 2008

80 Harpswell Road, Brunswick, ME 04011 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(13) · Ladders in construction
Serious$750$375Aug 12, 2008Closed
Citation 1, item 2
29 CFR 1926.1060(b) · Ladder and stairway training
Serious$450$225Aug 12, 2008Closed

Inspection 112570270 OPENED APR 16, 2003Closed

Unprogrammed other · Complete · Safety · 4 employees at the site · Closed Apr 16, 2003

705 Wilson Street, Brewer, ME 04412 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 113799852 OPENED OCT 2, 2002Closed

Planned · Complete · Safety · 1 employee at the site · Closed Feb 13, 2003

7 Custom House Street, Portland, ME 04101 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$1,400$800Oct 31, 2002Closed
Citation 1, item 2
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$600$300Oct 31, 2002Closed
Citation 2, item 1
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Repeat$2,800$1,900Oct 31, 2002Closed

Inspection 113800619 OPENED AUG 29, 2002Closed

Unprogrammed other · Complete · Safety · 2 employees at the site · Closed Sep 24, 2002

Gorham Road, South Portland, ME 04106 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.25(a) · Housekeeping
Serious$600$300Sep 4, 2002Closed

Inspection 303787550 OPENED OCT 18, 2001Closed

Planned · Complete · Safety · 10 employees at the site · Closed Dec 26, 2001

100 Mount Auburn Avenue, Auburn, ME 04210 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$500$500Nov 29, 2001Closed

Inspection 303784227 OPENED MAR 15, 2001Closed

Planned · Complete · Safety · 7 employees at the site · Closed Apr 20, 2001

325 Kennedy Memorial Drive, Waterville, ME 04901 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$500$250Apr 11, 2001Closed
Citation 1, item 2
29 CFR 1926.503(c)(3) · Fall protection training in construction
Serious$375$188Apr 11, 2001Closed
1 older inspection

Inspection 117919068 OPENED JAN 25, 2001Closed

Planned · Complete · Safety · 7 employees at the site · Closed Apr 6, 2001

Commercial Custom House Street, Portland, ME 04101 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$1,225$1,225Feb 16, 2001Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(13)

(13) The top or top step of a stepladder shall not be used as a step.

29 CFR 1926.1060 · Ladder and stairway training

29 CFR 1926.1060(b)

(b) Retraining shall be provided for each employee as necessary so that the employee maintains the understanding and knowledge acquired through compliance with this section.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.20(b)(2)

(2) Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.

29 CFR 1926.25 · Housekeeping

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other drywall and insulation contractors employers in Maine

Alert subscribers get notified of each newly cited employer in Maine the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.