Tire Outlet M & G, LLC: OSHA inspections and violations

Jacksonville Beach, Florida · General Automotive Repair · NAICS 811111

1inspections
4citation items
$12,055current penalties
Jun 8, 2023last inspection

OSHA inspectors have visited Tire Outlet M & G, LLC in Florida one time.

It opened on Jun 8, 2023 after a complaint, in Jacksonville Beach.

In all, OSHA issued 4 citation items: 4 serious.

The proposed penalties came to $20,092; today they stand at $12,055, 40% less.

The rule cited most here is 1910.305 (electrical wiring methods), 2 times.

Among repair and personal services employers, the typical cited inspection since 2015 ends with a $1,200 penalty. Tire Outlet M & G, LLC averages $12,055 across 1 cited inspection.

Tire Outlet M & G, LLC: OSHA citation items per year, 2023 to 2023
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

311employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Tire Outlet M & G, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346756190 OPENED JUN 8, 2023Closed

Complaint · Partial · Safety · 7 employees at the site · Closed Oct 18, 2023

1250 3rd Street North, Jacksonville Beach, FL 32250 · General Automotive Repair · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$10,046$6,028Sep 13, 2023Final
Citation 1, item 2a
29 CFR 1910.305(d)(2) · Electrical wiring methods
Serious$10,046$6,028Sep 13, 2023Final
Citation 1, item 2b
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Serious$0$0Sep 13, 2023Final
Citation 1, item 2c
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$0$0Sep 13, 2023Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(f)(2)

(2) Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(b)(1)(ii)

(ii) Unused openings in cabinets, boxes, and fittings shall be effectively closed.

29 CFR 1910.305(d)(2)

(2) Panelboard enclosures. Panelboards shall be mounted in cabinets, cutout boxes, or enclosures designed for the purpose and shall be dead front. However, panelboards other than the dead front externally-operable type are permitted where accessible only to qualified persons.