OSHA SearchOSHA records by employer

Titan Group Construction, LLC: OSHA inspections and violations

Ocean City, Maryland · New Single-Family Housing Construction (except For-Sale Builders) · NAICS 236115

1inspections
4citation items
$600current penalties
Mar 16, 2017last inspection

OSHA has inspected Titan Group Construction, LLC once in Maryland.

The inspection began on Mar 16, 2017 as a planned inspection, in Ocean City.

That inspection ended with 4 citation items: 3 serious and 1 other-than-serious.

Penalties were first proposed at $1,125 and now stand at $600, 47% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Titan Group Construction, LLC averages $600 (1 cited inspection).

Titan Group Construction, LLC: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

189employers cited

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch Titan Group Construction, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342181179 OPENED MAR 16, 2017Closed

Planned · Complete · Safety · 2 employees at the site · Closed Jun 15, 2017

17 141st Street, Ocean City, MD 21842 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.154(b)(3) · Temporary heating devices
Serious$375$200May 9, 2017Final
Citation 1, item 2a
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$750$400May 9, 2017Final
Citation 1, item 2b
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$0$0May 9, 2017Final
Citation 2, item 1
29 CFR 1926.1052(c)(1)(ii) · Stairways in construction
Other-than-serious$0$0May 9, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)(ii)

(ii) One stairrail system along each unprotected side or edge.

29 CFR 1926.154 · Temporary heating devices

29 CFR 1926.154(b)(3)

(3) Heaters not suitable for use on wood floors shall not be set directly upon them or other combustible materials. When such heaters are used, they shall rest on suitable heat insulating material or at least 1-inch concrete, or equivalent. The insulating material shall extend beyond the heater 2 feet or more in all directions.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(13)

(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.

29 CFR 1926.503 · Fall protection training in construction

Other new single-family housing construction (except for-sale builders) employers in Maryland

Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.