OSHA SearchOSHA records by employer

TL Becker Corp: OSHA inspections and violations

Eugene, Oregon · Aluminum Foundries (except Die-Casting) · NAICS 331524

5inspections
25citation items
$1,675current penalties
Sep 7, 2023last inspection

TL Becker Corp has 5 OSHA inspections on record in Oregon, the first in 2009.

OSHA's last visit started on Sep 7, 2023 as a planned inspection, in Eugene.

Across those inspections OSHA issued 25 citation items: 14 serious and 11 other-than-serious.

OSHA proposed $1,675 in penalties and the amount has not been reduced.

Most often, OSHA cited 1910.305, electrical wiring methods (3 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. TL Becker Corp averages $655 over 2 cited inspections in that time.

TL Becker Corp: OSHA citation items per year, 2009 to 2023
Citation items per year, by inspection date.

Oregon · latest 90 days of OSHA records

384employers cited

Get notified the morning OSHA posts each new citation in Oregon: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oregon

Checking a subcontractor, a client or your own company? Watch TL Becker Corp and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346961576 OPENED SEP 7, 2023Closed

Planned · Complete · Safety · 7 employees at the site · Closed Apr 25, 2024

30016 Leghorn Ave, Eugene, OR 97402 · Aluminum Foundries (except Die-Casting) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR OAR 437-002-0228(1)(J)
Serious$185$185Nov 20, 2023Final
Citation 1, item 1b
29 CFR OAR 437-002-0228(2)(C)
Serious$0$0Nov 20, 2023Final
Citation 1, item 2a
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$100$100Nov 20, 2023Final
Citation 1, item 2b
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Serious$0$0Nov 20, 2023Final
Citation 1, item 3
29 CFR 1910.219(c)(2)(i) · Belts, pulleys and power-transmission parts
Serious$100$100Nov 20, 2023Final
Citation 1, item 4
29 CFR 1910.242(b) · Hand and power tools
Serious$100$100Nov 20, 2023Final
Citation 2, item 5
29 CFR OAR 437-001-0765(13)-1
Other-than-serious$0$0Nov 20, 2023Final
Citation 2, item 6
29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Nov 20, 2023Final
Citation 2, item 7
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Other-than-serious$0$0Nov 20, 2023Final
Citation 2, item 8
29 CFR 1910.147(c)(7)(iv) · Lockout/tagout
Other-than-serious$0$0Nov 20, 2023Final

Inspection 343711537 OPENED JAN 10, 2019Closed

Follow-up · Partial · Safety · 8 employees at the site · Closed Jan 10, 2019

30016 Leghorn Ave, Eugene, OR 97402 · Aluminum Foundries (except Die-Casting) · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343198834 OPENED MAY 31, 2018Closed

Planned · Complete · Safety · 7 employees at the site · Closed Apr 5, 2019

30016 Leghorn Ave, Eugene, OR 97402 · Aluminum Foundries (except Die-Casting) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$525$525Oct 8, 2018Final
Citation 1, item 2
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$100$100Oct 8, 2018Final
Citation 1, item 3
29 CFR 1910.178(l)(1)(ii) · Forklifts and other powered industrial trucks
Serious$100$100Oct 8, 2018Final
Citation 1, item 4
29 CFR 1910.213(p)(4) · Woodworking machinery
Serious$100$100Oct 8, 2018Final
Citation 2, item 5
29 CFR OAR 437-001-0765(11)-3
Other-than-serious$0$0Oct 8, 2018Final
Citation 2, item 6
29 CFR OAR 437-002-0187(4)-2
Other-than-serious$0$0Oct 8, 2018Final
Citation 2, item 7
29 CFR OAR 437-002-0228(1)(J)
Other-than-serious$0$0Oct 8, 2018Final

Inspection 315898817 OPENED NOV 16, 2011Closed

Planned · Complete · Health · 7 employees at the site · Closed Jun 28, 2012

30016 Leghorn Ave, Eugene, OR 97402 · Aluminum Foundries (except Die-Casting) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$165$165Feb 2, 2012Closed
Citation 1, item 1b
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Feb 2, 2012Closed
Citation 2, item 2
29 CFR 1910.1200(h)(3)(ii) · Hazard communication
Other-than-serious$0$0Feb 2, 2012Closed
Citation 2, item 3 Other-than-serious$0$0Feb 2, 2012Closed

Inspection 313773392 OPENED DEC 22, 2009Closed

Planned · Complete · Safety · 7 employees at the site · Closed Jun 1, 2010

29250 Meadowview Rd, Junction City, OR 97448 · Aluminum Foundries (except Die-Casting) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$100$100Jan 22, 2010Closed
Citation 1, item 2
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$100$100Jan 22, 2010Closed
Citation 2, item 3 Other-than-serious$0$0Jan 22, 2010Closed
Citation 2, item 4
29 CFR 1910.178(l)(1)(ii) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Jan 22, 2010Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(h)(3)(ii)

(ii) The physical, health, simple asphyxiation, combustible dust, and pyrophoric gas hazards, as well as hazards not otherwise classified, of the chemicals in the work area;

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(1)

(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.

29 CFR 1910.134(e)(1)

(1) General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 7010.7651

29 CFR 7020.1870

Other aluminum foundries (except die-casting) employers in Oregon

Alert subscribers get notified of each newly cited employer in Oregon the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.