Inspection 343749511 OPENED JAN 29, 2019Closed
615 Atlantic Avenue, Virginia Beach, VA 23451 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.25(a) · Housekeeping |
Serious | $5,085 | $2,542 | Mar 20, 2019 | Final |
| Citation 1, item 1b 29 CFR 1926.351(d)(1) · Arc welding and cutting |
Serious | $5,085 | $0 | Mar 20, 2019 | Final |
| Citation 1, item 1c 29 CFR 1926.552(c)(1) · Material hoists, personnel hoists, and elevators |
Serious | $9,710 | $0 | Mar 20, 2019 | Final |
| Citation 1, item 1d 29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements |
Serious | $7,400 | $0 | Mar 20, 2019 | Final |
| Citation 1, item 5a 29 CFR 1926.403(h) · Electrical equipment on job sites |
Serious | $9,710 | $4,855 | Mar 20, 2019 | Final |
| Citation 1, item 5b 29 CFR 1926.403(i)(1)(i) · Electrical equipment on job sites |
Serious | $0 | $0 | Mar 20, 2019 | Final |
| Citation 1, item 5c 29 CFR 1926.403(b)(2) · Electrical equipment on job sites |
Serious | $9,710 | $0 | Mar 20, 2019 | Final |
| Citation 1, item 5d 29 CFR 1926.403(d)(1) · Electrical equipment on job sites |
Serious | $9,710 | $0 | Mar 20, 2019 | Final |
| Citation 1, item 5e 29 CFR 1926.403(i)(2)(i) · Electrical equipment on job sites |
Serious | $11,455 | $0 | Mar 20, 2019 | Final |
| Citation 1, item 5f 29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites |
Serious | $11,455 | $0 | Mar 20, 2019 | Final |
| Citation 1, item 5g 29 CFR 1926.404(f)(6) · Ground-fault protection on job sites |
Serious | $9,710 | $0 | Mar 20, 2019 | Final |
| Citation 1, item 5h 29 CFR 1926.405(a)(2)(ii)(i) · Job-site wiring |
Serious | $11,455 | $0 | Mar 20, 2019 | Final |
| Citation 1, item 6b 29 CFR 1926.405(d) · Job-site wiring |
Serious | $0 | $0 | Mar 20, 2019 | Final |
| Citation 1, item 6c 29 CFR 1926.405(j)(1)(i) · Job-site wiring |
Serious | $0 | $0 | Mar 20, 2019 | Final |
| Citation 1, item 8b 29 CFR 1926.405(a)(2)(ii)(j) · Job-site wiring |
Serious | $0 | $0 | Mar 20, 2019 | Final |
| Citation 1, item 9a 29 CFR 1926.405(a)(2)(ii)(e) · Job-site wiring |
Serious | $9,710 | $4,855 | Mar 20, 2019 | Final |
| Citation 1, item 9b 29 CFR 1926.405(a)(2)(ii)(f) · Job-site wiring |
Serious | $0 | $0 | Mar 20, 2019 | Final |
| Citation 1, item 9c 29 CFR 1926.405(a)(2)(ii)(c) · Job-site wiring |
Serious | $0 | $0 | Mar 20, 2019 | Final |
| Citation 1, item 10b 29 CFR 1926.405(g)(2)(iv) · Job-site wiring |
Serious | $0 | $0 | Mar 20, 2019 | Final |
| Citation 1, item 10c 29 CFR 1926.416(e)(1) · Electrical safety in construction |
Serious | $0 | $0 | Mar 20, 2019 | Final |
| Citation 1, item 11a 29 CFR 1926.451(f)(3) · Scaffolds, general requirements |
Serious | $9,710 | $4,855 | Mar 20, 2019 | Final |
| Citation 1, item 11b 29 CFR 1926.454(a) · Scaffold training |
Serious | $0 | $0 | Mar 20, 2019 | Final |
| Citation 1, item 11c 29 CFR 1926.454(b) · Scaffold training |
Serious | $0 | $0 | Mar 20, 2019 | Final |
| Citation 1, item 12a 29 CFR 1926.501(b)(1) · Fall protection in construction |
Serious | $11,455 | $5,728 | Mar 20, 2019 | Final |
| Citation 1, item 12b 29 CFR 1926.502(b)(1) · Fall protection systems |
Serious | $0 | $0 | Mar 20, 2019 | Final |
| Citation 1, item 12c 29 CFR 1926.503(a)(1) · Fall protection training in construction |
Serious | $0 | $0 | Mar 20, 2019 | Final |
| Citation 1, item 12d 29 CFR 1926.1052(c)(12) · Stairways in construction |
Serious | $0 | $0 | Mar 20, 2019 | Final |
| Citation 1, item 12e 29 CFR 1926.501(b)(4)(ii) · Fall protection in construction |
Serious | $8,785 | $0 | Mar 20, 2019 | Final |
| Citation 1, item 12f 29 CFR 1926.501(c)(1) · Fall protection in construction |
Serious | $8,785 | $0 | Mar 20, 2019 | Final |