OSHA SearchOSHA records by employer

Transition of Superior Systems, L.C.: OSHA inspections and violations

Merkel, Texas · Fabricated Structural Metal Manufacturing · NAICS 332312

1inspections
4citation items
$8,448current penalties
Mar 17, 2016last inspection

Transition of Superior Systems, L.C. has one OSHA inspection on record in Texas.

OSHA opened it on Mar 17, 2016 to follow up on an earlier case, in Merkel.

From that inspection OSHA issued 4 citation items: 2 serious and 2 repeat.

OSHA proposed $14,080 in penalties. After settlements and reviews the total is $8,448, down 40%.

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Transition of Superior Systems, L.C. averages $8,448 over 1 cited inspection in that time.

Transition of Superior Systems, L.C.: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

404employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Transition of Superior Systems, L.C. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341332500 OPENED MAR 17, 2016Closed

Follow-up · Partial · Health · 12 employees at the site · Closed Oct 25, 2016

274 Cr 287, Merkel, TX 79536 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$1,760$1,056Jun 30, 2016Final
Citation 1, item 2
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Serious$2,640$1,584Jun 30, 2016Final
Citation 2, item 1
29 CFR 1910.179(j)(2)(iii) · Overhead and gantry cranes
Repeat$4,400$2,640Jun 30, 2016Final
Citation 2, item 2
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Repeat$5,280$3,168Jun 30, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(e)(1)

(1) General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.179(j)(2)(iii)

(iii) Hooks with deformation or cracks. Visual inspection daily; monthly inspection with a certification record which includes the date of inspection, the signature of the person who performed the inspection and the serial number, or other identifier, of the hook inspected. For hooks with cracks or having more than 15 percent in excess of normal throat opening or more than 10° twist from the plane of the unbent hook refer to paragraph (l)(3)(iii)(a) of this section.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(g)(1)

(1) Space about electric equipment. Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment.

29 CFR 1910.305 · Electrical wiring methods

Other fabricated structural metal manufacturing employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.