Transportation Repair Service Inc.: OSHA inspections and violations

East Syracuse, New York · General Automotive Repair · NAICS 811111

1inspections
14citation items
$5,980current penalties
Oct 1, 2015last inspection

Transportation Repair Service Inc. has one OSHA inspection on record in New York.

OSHA opened it on Oct 1, 2015 after a complaint, in East Syracuse.

From that inspection OSHA issued 14 citation items: 14 serious.

OSHA proposed $9,200 in penalties. After settlements and reviews the total is $5,980, down 35%.

Most often, OSHA cited 1910.134, respiratory protection (5 items).

For context, across all repair and personal services employers the median penalty per cited inspection since 2015 is $1,200. Transportation Repair Service Inc. averages $5,980 over 1 cited inspection in that time.

Transportation Repair Service Inc.: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

376employers cited

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Transportation Repair Service Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340958487 OPENED OCT 1, 2015Closed

Complaint · Partial · Health · 14 employees at the site · Closed Sep 13, 2017

7314 Schuyler Road, East Syracuse, NY 13057 · General Automotive Repair · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Serious$1,600$1,040Nov 10, 2015Final
Citation 1, item 1b
29 CFR 1910.106(d)(4)(iv) · Flammable liquids
Serious$0$0Nov 10, 2015Final
Citation 1, item 2a
29 CFR 1910.106(e)(6)(i) · Flammable liquids
Serious$1,600$1,040Nov 10, 2015Final
Citation 1, item 2b
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$0$0Nov 10, 2015Final
Citation 1, item 3a
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Serious$1,600$1,040Nov 10, 2015Final
Citation 1, item 3b
29 CFR 1910.107(b)(9) · Spray painting and finishing
Serious$0$0Nov 10, 2015Final
Citation 1, item 4a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$1,200$780Nov 10, 2015Final
Citation 1, item 4b
29 CFR 1910.134(d)(1)(iii) · Respiratory protection
Serious$0$0Nov 10, 2015Final
Citation 1, item 4c
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Nov 10, 2015Final
Citation 1, item 4d
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0Nov 10, 2015Final
Citation 1, item 4e
29 CFR 1910.134(k)(1) · Respiratory protection
Serious$0$0Nov 10, 2015Final
Citation 1, item 5
29 CFR 1910.157(g)(2) · Portable fire extinguishers
Serious$1,200$780Nov 10, 2015Final
Citation 1, item 6a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$2,000$1,300Nov 10, 2015Final
Citation 1, item 6b
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$0$0Nov 10, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(4)(i)

(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra

29 CFR 1910.106(d)(4)(iv)

(iv) Ventilation. Every inside storage room shall be provided with either a gravity or a mechanical exhaust ventilation system. Such system shall be designed to provide for a complete change of air within the room at least six times per hour. If a mechanical exhaust system is used, it shall be controlled by a switch located outside of the door. The ventilating equipment and any lighting fixtures shall be operated by the same switch. A pilot light shall be installed adjacent to the switch if Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), are dispensed within the room. Where gravity ventilation is provided, the fresh air intake, as well as the exhaust outlet from the room, shall be on the exterior of the building in which the room is located.

29 CFR 1910.106(e)(6)(i)

(6) Sources of ignition—(i) General. Adequate precautions shall be taken to prevent the ignition of flammable vapors. Sources of ignition include but are not limited to open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.157 · Portable fire extinguishers

Other general automotive repair employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.