OSHA SearchOSHA records by employer

Trenwa, Inc: OSHA inspections and violations

Brookshire, Texas · Other Concrete Product Manufacturing · NAICS 327390

2inspections
11citation items
$20,710current penalties
Nov 8, 2023last inspection

Since 2019, OSHA inspectors have visited Trenwa, Inc in Texas 2 times.

The most recent inspection opened on Nov 8, 2023 after a complaint, in Brookshire.

In all, OSHA issued 11 citation items: 3 serious and 8 other-than-serious.

The proposed penalties came to $61,120; today they stand at $20,710, 66% less.

The rule cited most here is 1910.1053 (silica dust in general industry), 5 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. Trenwa, Inc averages $10,355 across 2 cited inspections.

Trenwa, Inc also files yearly injury logs with OSHA, summarized below.

Trenwa, Inc: OSHA citation items per year, 2019 to 2023
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

394employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Trenwa, Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347095820 OPENED NOV 8, 2023Closed

Complaint · Partial · Safety · 22 employees at the site · Closed Feb 14, 2024

34229 Sunset Lane, Brookshire, TX 77423 · Other Concrete Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.37(a)(3) · Exit routes
Serious$4,839$2,903Jan 30, 2024Final
Citation 1, item 2
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Serious$6,453$3,872Jan 30, 2024Final
Citation 1, item 3
29 CFR 1910.334(a)(2)(i) · Using electrical equipment
Serious$6,453$3,872Jan 30, 2024Final
Citation 2, item 1
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Jan 30, 2024Final

Inspection 344471602 OPENED NOV 25, 2019Closed

Complaint · Partial · Health · 15 employees at the site · Closed Dec 21, 2020

34229 Sunset Lane, Brookshire, TX 77423 · Other Concrete Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.138(a) · Gloves and hand protection
Other-than-serious$5,205$3,019Mar 27, 2020Final
Citation 1, item 1b
29 CFR 1910.151(c) · First aid and eyewash
Other-than-serious$8,675$0Mar 27, 2020Final
Citation 1, item 2a
29 CFR 1910.1053(c) · Silica dust in general industry
Other-than-serious$12,145$7,044Mar 27, 2020Final
Citation 1, item 2b
29 CFR 1910.1053(d)(1) · Silica dust in general industry
Other-than-serious$8,675$0Mar 27, 2020Final
Citation 1, item 2c
29 CFR 1910.1053(f)(2)(i) · Silica dust in general industry
Other-than-serious$0$0Mar 27, 2020Final
Citation 1, item 2d
29 CFR 1910.1053(h)(1) · Silica dust in general industry
Other-than-serious$8,675$0Mar 27, 2020Final
Citation 1, item 2e
29 CFR 1910.1053(h)(2)(i) · Silica dust in general industry
Other-than-serious$0$0Mar 27, 2020Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2023, the Brookshire site logged 2 recordable injuries or illnesses among about 20 workers: 8.5 per 100 full-time workers, against a median of 3.4 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Brookshire, TX Plant
Brookshire · 2023
20 208.53.4

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1053 · Silica dust in general industry

29 CFR 1910.1053(c)

(c) Permissible exposure limit (PEL). The employer shall ensure that no employee is exposed to an airborne concentration of respirable crystalline silica in excess of 50 µg/m 3, calculated as an 8-hour TWA.

29 CFR 1910.1053(d)(1)

(d) Exposure assessment—(1) General. The employer shall assess the exposure of each employee who is or may reasonably be expected to be exposed to respirable crystalline silica at or above the action level in accordance with either the performance option in paragraph (d)(2) or the scheduled monitoring option in paragraph (d)(3) of this section.

29 CFR 1910.1053(f)(2)(i)

(2) Written exposure control plan. (i) The employer shall establish and implement a written exposure control plan that contains at least the following elements:

29 CFR 1910.138 · Gloves and hand protection

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.37 · Exit routes