Trinity Stainless Inc.: OSHA inspections and violations
Nixa, Missouri · Iron and Steel Pipe and Tube Manufacturing from Purchased Steel · NAICS 331210
2inspections
3citation items
$1,428current penalties
Jan 20, 2017last inspection
OSHA has inspected Trinity Stainless Inc. 2 times in Missouri since 2015.
The latest one began on Jan 20, 2017 as a planned inspection, in Nixa.
Those inspections ended with 3 citation items: 2 serious and 1 other-than-serious.
Penalties were first proposed at $2,040 and now stand at $1,428, 30% lower after settlements or reviews.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Trinity Stainless Inc. averages $714 (2 cited inspections).
Trinity Stainless Inc. also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
Want to know if OSHA cites Trinity Stainless Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2022, the Nixa site logged 0 recordable injuries or illnesses among about 20 workers: 0.0 per 100 full-time workers, against a median of 1.8 for its industry.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
Trinity Stainless Inc.
Nixa · 2022
20
0
0
0.0
1.8
Trinity Stainless Inc
Nixa · 2021
20
0
0
0.0
1.8
The rules behind these citations
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.178 · Forklifts and other powered industrial trucks
29 CFR 1910.178(l)(4)(iii)
(iii) An evaluation of each powered industrial truck operator's performance shall be conducted at least once every three years.
(9) Exposure adjustment. Safety guards of the types described in subparagraphs (3) and (4) of this paragraph, where the operator stands in front of the opening, shall be constructed so that the peripheral protecting member can be adjusted to the constantly decreasing diameter of the wheel. The maximum angular exposure above the horizontal plane of the wheel spindle as specified in paragraphs (b) (3) and (4) of this section shall never be exceeded, and the distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top shall never exceed one-fourth inch. (See Figures O-18, O-19, O-20, O-21, O-22, and O-23.)
29 CFR 1910.303 · Electrical equipment, general requirements
29 CFR 1910.303(g)(1)(iii)
(iii) At least one entrance of sufficient area shall be provided to give access to the working space about electric equipment.
Other iron and steel pipe and tube manufacturing from purchased steel employers in Missouri
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.