Inspection 340777770 OPENED JUN 25, 2015Closed
526 Pine Street, Glenwood Springs, CO 81601 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Glenwood Springs, Colorado · Water and Sewer Line and Related Structures Construction · NAICS 237110
Since 2015, OSHA inspectors have visited Underhill Excavating, Inc. in Colorado 3 times.
The most recent inspection opened on Jun 25, 2015 to follow up on an earlier case, in Glenwood Springs.
In all, OSHA issued 4 citation items: 4 serious.
The proposed penalties came to $7,200; today they stand at $5,240, 27% less.
The rule cited most here is 1926.652 (trench protection), 2 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Underhill Excavating, Inc. averages $2,620 across 2 cited inspections.
Colorado · latest 90 days of OSHA records
130employers cited
3 of them in the same industry
Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Colorado
Checking a subcontractor, a client or your own company? Watch Underhill Excavating, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company526 Pine Street, Glenwood Springs, CO 81601 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
526 Pine Street, Glenwood Springs, CO 81601 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.652(a)(1) · Trench protection |
Serious | $1,600 | $1,600 | May 6, 2015 | Final |
| Citation 1, item 1b 29 CFR 1926.651(k)(1) · Excavations |
Serious | $0 | $0 | May 6, 2015 | Final |
712 West Francis Street, Aspen, CO 81611 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.651(k)(1) · Excavations |
Serious | $2,800 | $1,820 | Apr 2, 2015 | Final |
| Citation 1, item 2 29 CFR 1926.652(a)(1) · Trench protection |
Serious | $2,800 | $1,820 | Apr 2, 2015 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.651(k)(1)
(k) Inspections. (1) Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated.
29 CFR 1926.652(a)(1)
(a) Protection of employees in excavations. (1) Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section except when:
Alert subscribers get notified of each newly cited employer in Colorado the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.