OSHA SearchOSHA records by employer

United Erectors 2, LLC: OSHA inspections and violations

Corpus Christi, Texas · Structural Steel and Precast Concrete Contractors · NAICS 238120

3inspections
8citation items
$37,619current penalties
Apr 21, 2021last inspection

Since 2019, OSHA inspectors have visited United Erectors 2, LLC in Texas 3 times.

The most recent inspection opened on Apr 21, 2021 as a planned inspection, in San Antonio and is still open.

In all, OSHA issued 8 citation items: 5 serious, 2 repeat and 1 other-than-serious.

The penalties, $37,619 in total, stand where OSHA first set them.

The rule cited most here is 1926.453 (aerial lifts), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. United Erectors 2, LLC averages $12,540 across 3 cited inspections.

United Erectors 2, LLC: OSHA citation items per year, 2019 to 2021
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

391employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch United Erectors 2, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345265102 OPENED APR 21, 2021Open

Planned · Partial · Safety · 15 employees at the site · Open

3602 S. W W White Road, San Antonio, TX 78222 · Other Building Equipment Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$3,121$3,121Sep 27, 2021Final

Inspection 344432547 OPENED NOV 6, 2019Closed

Complaint · Partial · Safety · 15 employees at the site · Closed Sep 18, 2023

1751 Cr 282, Liberty Hill, TX 78642 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.602(c)(1)(ii) · Earthmovers and forklifts in construction
Serious$3,789$3,789Jan 14, 2020Final
Citation 1, item 1b
29 CFR 1926.451(c)(2)(iv) · Scaffolds, general requirements
Serious$0$0Jan 14, 2020Final
Citation 2, item 1
29 CFR 1910.178(l)(6) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Jan 14, 2020Final
Citation 3, item 1
29 CFR 1926.451(c)(2)(v) · Scaffolds, general requirements
Repeat$7,578$7,578Jan 14, 2020Final

Inspection 343937751 OPENED APR 16, 2019Closed

Planned · Partial · Safety · 5 employees at the site · Closed Jan 6, 2026

3875 S Staples St, Corpus Christi, TX 78411 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(4)(ii) · Fall protection in construction
Serious$4,376$4,376Apr 23, 2019Final
Citation 1, item 2
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$3,126$3,126Apr 23, 2019Final
Citation 2, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Repeat$15,629$15,629Apr 23, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.178(l)(6)

(6) Certification. The employer shall certify that each operator has been trained and evaluated as required by this paragraph (l). The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(2)(iv)

(iv) Front-end loaders and similar pieces of equipment shall not be used to support scaffold platforms unless they have been specifically designed by the manufacturer for such use.

29 CFR 1926.451(c)(2)(v)

(v) Fork-lifts shall not be used to support scaffold platforms unless the entire platform is attached to the fork and the fork-lift is not moved horizontally while the platform is occupied.

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.602 · Earthmovers and forklifts in construction

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

Other structural steel and precast concrete contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.