OSHA SearchOSHA records by employer

Unlimited Carpentry, LLC: OSHA inspections and violations

Cincinnati, Ohio · Residential Remodelers · NAICS 236118

2inspections
4citation items
$4,038current penalties
Mar 12, 2026last inspection

Since 2017, OSHA inspectors have visited Unlimited Carpentry, LLC in Ohio 2 times.

The most recent inspection opened on Mar 12, 2026 after a complaint, in Cincinnati.

In all, OSHA issued 4 citation items: 4 serious.

The proposed penalties came to $12,317; today they stand at $4,038, 67% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Unlimited Carpentry, LLC averages $2,019 across 2 cited inspections.

Unlimited Carpentry, LLC: OSHA citation items per year, 2017 to 2026
Citation items per year, by inspection date.

Ohio · latest 90 days of OSHA records

265employers cited

Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Ohio

Checking a subcontractor, a client or your own company? Watch Unlimited Carpentry, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348804543 OPENED MAR 12, 2026Closed

Complaint · Partial · Safety · 3 employees at the site · Closed Aug 20, 2026

2703 Park Avenue, Cincinnati, OH 45244 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$2,838$2,838May 15, 2026Final
Citation 1, item 1b
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$2,838$0May 15, 2026Final
Citation 1, item 1c
29 CFR 1926.454(a) · Scaffold training
Serious$2,838$0May 15, 2026Final

Inspection 342780798 OPENED NOV 17, 2017Closed

Planned · Partial · Safety · 10 employees at the site · Closed May 1, 2018

1529 Ruth Avenue, Cincinnati, OH 45207 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$3,803$1,200Dec 11, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

29 CFR 1926.451(g)(1)

(g) Fall protection. (1) Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1) (i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers.

29 CFR 1926.454 · Scaffold training

29 CFR 1926.454(a)

(a) The employer shall have each employee who performs work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. The training shall include the following areas, as applicable:

29 CFR 1926.501 · Fall protection in construction

Other residential remodelers employers in Ohio

Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.