OSHA SearchOSHA records by employer

Upchurch Machine Co., Inc.: OSHA inspections and violations

Charlotte, North Carolina · Metalworking Machinery Manufacturing · NAICS 333512

6inspections
31citation items
$4,100current penalties
Sep 4, 2018last inspection

Upchurch Machine Co., Inc. has 6 OSHA inspections on record in North Carolina, the first in 1995.

OSHA's last visit started on Sep 4, 2018 after a complaint, in Charlotte.

Across those inspections OSHA issued 31 citation items: 12 serious, 2 repeat and 17 other-than-serious.

OSHA proposed $7,500 in penalties. After settlements and reviews the total is $4,100, down 45%.

Most often, OSHA cited 1910.1200, hazard communication (7 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Upchurch Machine Co., Inc. averages $0 over 1 cited inspection in that time.

Upchurch Machine Co., Inc.: OSHA citation items per year, 1995 to 2018
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

228employers cited

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Upchurch Machine Co., Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343438214 OPENED SEP 4, 2018Closed

Complaint · Partial · Health · 17 employees at the site · Closed Oct 9, 2018

11633 Fruehauf Dr, Charlotte, NC 28273 · Machine Shops · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Oct 3, 2018Final
Citation 1, item 2
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Oct 3, 2018Final
Citation 1, item 3
29 CFR 1910.1200(h)(3)(ii) · Hazard communication
Other-than-serious$0$0Oct 3, 2018Final

Inspection 316608991 OPENED JUN 20, 2012Closed

Planned · Complete · Safety · 14 employees at the site · Closed Nov 5, 2012

11633 Fruehauf Drive, Charlotte, NC 28241 · Metalworking Machinery Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$500$100Aug 3, 2012Closed
Citation 1, item 1b
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$0$0Aug 3, 2012Closed
Citation 1, item 1c
29 CFR 1910.147(c)(5)(iid) · Lockout/tagout
Serious$0$0Aug 3, 2012Closed
Citation 1, item 1d
29 CFR 1910.147(c)(6)(ic) · Lockout/tagout
Serious$0$0Aug 3, 2012Closed
Citation 1, item 1e
29 CFR 1910.147(c)(8) · Lockout/tagout
Serious$0$0Aug 3, 2012Closed
Citation 1, item 2
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Serious$1,400$300Aug 3, 2012Closed
Citation 1, item 3
29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks
Serious$500$300Aug 3, 2012Closed
Citation 1, item 4
29 CFR 1910.212(a)(1) · Machine guarding
Serious$1,400$100Aug 3, 2012Closed
Citation 1, item 5
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$300$100Aug 3, 2012Closed
Citation 1, item 6
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$300$100Aug 3, 2012Closed
Citation 2, item 1
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Aug 3, 2012Closed
Citation 2, item 2
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0Aug 3, 2012Closed
Citation 2, item 3
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Aug 3, 2012Closed
Citation 2, item 4
29 CFR 1910.303(f)(1) · Electrical equipment, general requirements
Other-than-serious$0$0Aug 3, 2012Closed
Citation 2, item 5
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Aug 3, 2012Closed

Inspection 303755441 OPENED JUL 7, 2000Closed

Complaint · Partial · Safety · 30 employees at the site · Closed Apr 2, 2001

11633 Fruehauf Dr., Charlotte, NC 28241 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 303496194 OPENED MAR 30, 2000Closed

Complaint · Partial · Health · 27 employees at the site · Closed Jun 22, 2000

11633 Fruehauf Dr., Charlotte, NC 28241 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1200(h) · Hazard communication
Repeat$1,000$1,000Apr 28, 2000Closed
Citation 2, item 1
29 CFR 1910.101(b) · Compressed gases (general requirements)
Other-than-serious$0$0Apr 28, 2000Closed
Citation 2, item 2
29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Apr 28, 2000Closed
Citation 2, item 3
29 CFR 1910.252(b)(2)(iii) · Welding fire safety
Other-than-serious$0$0Apr 28, 2000Closed
Citation 2, item 4
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Apr 28, 2000Closed
Citation 2, item 5
29 CFR 1910.334(a)(2)(i) · Using electrical equipment
Other-than-serious$0$0Apr 28, 2000Closed

Inspection 302138011 OPENED APR 9, 1998Closed

Complaint · Partial · Health · 45 employees at the site · Closed May 26, 1998

11633 Fruehauf Dr., Charlotte, NC 28241 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1200(h)(1) · Hazard communication
Repeat$500$500May 11, 1998Closed

Inspection 125284166 OPENED OCT 31, 1995Closed

Planned · Complete · Health · 26 employees at the site · Closed Jun 25, 1997

11633 Fruehauf Dr., Charlotte, NC 28241 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.133(a)(3) · Eye and face protection
Serious$600$600Jan 17, 1996Closed
Citation 1, item 2
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$1,000$1,000Jan 17, 1996Closed
Citation 2, item 1a
29 CFR 1910.38(a)(1) · Emergency action plans
Other-than-serious$0$0Jan 17, 1996Closed
Citation 2, item 1b
29 CFR 1910.38(a)(5)(i) · Emergency action plans
Other-than-serious$0$0Jan 17, 1996Closed
Citation 2, item 2a
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Jan 17, 1996Closed
Citation 2, item 2b
29 CFR 1910.1200(h) · Hazard communication
Other-than-serious$0$0Jan 17, 1996Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.101 · Compressed gases (general requirements)

29 CFR 1910.101(b)

(b) Compressed gases. The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in § 1910.6.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.1200(h)

(h) Post-mortem data: Increased incidence and/or severity of post-mortem findings may be indicative of maternal toxicity. This can include gross or microscopic pathological findings or organ weight data, including absolute organ weight, organ-to-body weight ratio, or organ-to-brain weight ratio. When supported by findings of adverse histopathological effects in the affected organ(s), the observation of a significant change in the average weight of suspected target organ(s) of treated dams (mothers), compared to those in the control group, may be considered evidence of maternal toxicity.

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.38 · Emergency action plans

Other metalworking machinery manufacturing employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.