OSHA SearchOSHA records by employer

Upper Potomac River Commission: OSHA inspections and violations

Swanton, Maryland · Administration of Air and Water Resource and Solid Waste Management Programs · NAICS 924110

3inspections
78citation items
$0current penalties
May 30, 2019last inspection

Upper Potomac River Commission has 3 OSHA inspections on record in Maryland, the first in 1998.

OSHA's last visit started on May 30, 2019 on a referral, in Swanton.

Across those inspections OSHA issued 78 citation items: 44 serious and 34 other-than-serious.

OSHA did not attach a penalty to any of these citations.

Most often, OSHA cited 1910.146, permit-required confined spaces (25 items).

For context, across all public administration employers the median penalty per cited inspection since 2015 is $0. Upper Potomac River Commission averages $0 over 2 cited inspections in that time.

2 inspections on this page followed a fatal incident.

Upper Potomac River Commission: OSHA citation items per year, 1998 to 2019
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

195employers cited

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch Upper Potomac River Commission and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344048921 OPENED MAY 30, 2019Closed

Referral · Partial · Health · Local government · 3 employees at the site · Closed Apr 29, 2020

4610 Savage River Road, Swanton, MD 21561 · Administration of Air and Water Resource and Solid Waste Management Programs · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(b)(8) · Ladders in general industry
Serious$0$0Feb 19, 2020Final
Citation 1, item 2
29 CFR 1910.30(a)(1) · Training requirements
Serious$0$0Feb 19, 2020Final
Citation 2, item 1
29 CFR 1910.140(d)(1)(ii) · Personal fall protection systems
Other-than-serious$0$0Feb 19, 2020Final
Citation 2, item 2
29 CFR 1910.140(d)(2)(ii) · Personal fall protection systems
Other-than-serious$0$0Feb 19, 2020Final
Citation 2, item 3
29 CFR 1910.146(c)(4) · Permit-required confined spaces
Other-than-serious$0$0Feb 19, 2020Final
Citation 2, item 4
29 CFR 1910.146(h)(3) · Permit-required confined spaces
Other-than-serious$0$0Feb 19, 2020Final
Citation 2, item 5
29 CFR 1910.146(f)(7) · Permit-required confined spaces
Other-than-serious$0$0Feb 19, 2020Final
Citation 2, item 6
29 CFR 1910.146(f)(8) · Permit-required confined spaces
Other-than-serious$0$0Feb 19, 2020Final
Citation 2, item 7
29 CFR 1910.146(f)(11) · Permit-required confined spaces
Other-than-serious$0$0Feb 19, 2020Final
Citation 2, item 8
29 CFR 1910.146(f)(12) · Permit-required confined spaces
Other-than-serious$0$0Feb 19, 2020Final
Citation 2, item 9
29 CFR 1910.146(g)(1) · Permit-required confined spaces
Other-than-serious$0$0Feb 19, 2020Final
Citation 2, item 10
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Other-than-serious$0$0Feb 19, 2020Final
Citation 2, item 11
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Other-than-serious$0$0Feb 19, 2020Final
Citation 2, item 12
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Other-than-serious$0$0Feb 19, 2020Final
Citation 2, item 13
29 CFR 1910.147(d)(6) · Lockout/tagout
Other-than-serious$0$0Feb 19, 2020Final

Inspection 344007448 OPENED MAY 16, 2019Closed

Fatality or catastrophe · Complete · Safety · Local government · 5 employees at the site · Closed Nov 6, 2019

4610 Savage River Road, Swanton, MD 21561 · Administration of Air and Water Resource and Solid Waste Management Programs · OSHA's record · Phone and website on Google Maps

Incident on May 13, 2019 (fatal): Employee dies at dam

At 11:45 a.m. on May 13, 2019, an employee at dam drove with other employees to the top of the dam and parked the truck so that they could clear some wooden debris at the bottom of the embankment path next to the spillway. The employee went missing and was later found dead in the bottom of the spillway by water rescue.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.304(g)(6)(vi)(c)(1) · Grounding and circuit protection
Serious$0$0Oct 8, 2019Final
Citation 2, item 1
29 CFR 1904.39(a)(1) · Reporting deaths and severe injuries
Other-than-serious$0$0Oct 8, 2019Final
Citation 2, item 2
29 CFR 1910.305(g)(1)(iv) · Electrical wiring methods
Other-than-serious$0$0Oct 8, 2019Final

Inspection 302297908 OPENED SEP 17, 1998Closed

Accident · Complete · Safety · 27 employees at the site · Closed Jul 20, 1999

528 Maryland Avenue, Westernport, MD 21562 · OSHA's record · Phone and website on Google Maps

Incident on Sep 5, 1998 (fatal): Employee found drowned in wastewater treatment tank

At approximately 10:00 p.m. on September 5, 1998, Employee #1's drowned body was recovered from the Upper Potomac River Commission's wastewater treatment plant aerator tank #2. Police photographs show what appear to be foot marks on the saf ety rail around the tank in the area where it is believed that Employee #1 enter ed. There did not appear to have been violations of occupational safety and heal th laws and the guards around the tank were such that an employee could not ente r the tank accidentally or unintentionally. After a preliminary investigation of suicide, the police reclassified the death as simply unattended. The coroner fo und no evidence of foul play on the body and reported that death was due to drow ning. Employee #1 was the superintendent of the plant.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(d)(2)(iii) · Flammable liquids
Serious$0$0Dec 11, 1998Closed
Citation 2, item 1
29 CFR 1910.119(c)(1) · Process safety management
Serious$0$0Dec 11, 1998Closed
Citation 2, item 2
29 CFR 1910.119(g)(1)(i) · Process safety management
Serious$0$0Dec 11, 1998Closed
Citation 2, item 3
29 CFR 1910.119(h)(2)(i) · Process safety management
Serious$0$0Dec 11, 1998Closed
Citation 2, item 4
29 CFR 1910.119(h)(2)(ii) · Process safety management
Serious$0$0Dec 11, 1998Closed
Citation 2, item 5
29 CFR 1910.119(h)(2)(iii) · Process safety management
Serious$0$0Dec 11, 1998Closed
Citation 2, item 6
29 CFR 1910.119(h)(2)(iv) · Process safety management
Serious$0$0Dec 11, 1998Closed
Citation 2, item 7
29 CFR 1910.119(h)(2)(v) · Process safety management
Serious$0$0Dec 11, 1998Closed
Citation 2, item 8
29 CFR 1910.119(k)(1) · Process safety management
Serious$0$0Dec 11, 1998Closed
Citation 3, item 1
29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements
Serious$0$0Dec 11, 1998Closed
Citation 3, item 2
29 CFR 1910.132(f)(1) · Personal protective equipment, general requirements
Serious$0$0Dec 11, 1998Closed
Citation 4, item 1
29 CFR 1910.134(e)(3) · Respiratory protection
Serious$0$0Dec 11, 1998Closed
Citation 4, item 2
29 CFR 1910.134(e)(5) · Respiratory protection
Serious$0$0Dec 11, 1998Closed
Citation 4, item 3
29 CFR 1910.134(f)(2)(ii) · Respiratory protection
Serious$0$0Dec 11, 1998Closed
Citation 5, item 1
29 CFR 1910.146(d)(1) · Permit-required confined spaces
Serious$0$0Dec 11, 1998Closed
Citation 5, item 2
29 CFR 1910.146(d)(10) · Permit-required confined spaces
Serious$0$0Dec 11, 1998Closed
Citation 5, item 3
29 CFR 1910.146(d)(12) · Permit-required confined spaces
Serious$0$0Dec 11, 1998Closed
Citation 5, item 4
29 CFR 1910.146(d)(14) · Permit-required confined spaces
Serious$0$0Dec 11, 1998Closed
Citation 5, item 5
29 CFR 1910.146(e)(1) · Permit-required confined spaces
Serious$0$0Dec 11, 1998Closed
Citation 5, item 6
29 CFR 1910.146(e)(2) · Permit-required confined spaces
Serious$0$0Dec 11, 1998Closed
Citation 5, item 7
29 CFR 1910.146(e)(5)(i) · Permit-required confined spaces
Serious$0$0Dec 11, 1998Closed
Citation 5, item 8
29 CFR 1910.146(f)(2) · Permit-required confined spaces
Serious$0$0Dec 11, 1998Closed
Citation 5, item 9
29 CFR 1910.146(f)(3) · Permit-required confined spaces
Serious$0$0Dec 11, 1998Closed
Citation 5, item 10
29 CFR 1910.146(f)(6) · Permit-required confined spaces
Serious$0$0Dec 11, 1998Closed
Citation 5, item 11
29 CFR 1910.146(f)(7) · Permit-required confined spaces
Serious$0$0Dec 11, 1998Closed
Citation 5, item 12
29 CFR 1910.146(f)(10) · Permit-required confined spaces
Serious$0$0Dec 11, 1998Closed
Citation 5, item 13
29 CFR 1910.146(f)(11) · Permit-required confined spaces
Serious$0$0Dec 11, 1998Closed
Citation 5, item 14
29 CFR 1910.146(g)(1) · Permit-required confined spaces
Serious$0$0Dec 11, 1998Closed
Citation 5, item 15
29 CFR 1910.146(g)(4) · Permit-required confined spaces
Serious$0$0Dec 11, 1998Closed
Citation 5, item 16
29 CFR 1910.146(j)(2) · Permit-required confined spaces
Serious$0$0Dec 11, 1998Closed
Citation 5, item 17
29 CFR 1910.146(j)(3) · Permit-required confined spaces
Serious$0$0Dec 11, 1998Closed
Citation 5, item 18
29 CFR 1910.146(j)(4) · Permit-required confined spaces
Serious$0$0Dec 11, 1998Closed
Citation 6, item 1
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$0$0Dec 11, 1998Closed
Citation 6, item 2
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$0$0Dec 11, 1998Closed
Citation 6, item 3
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$0$0Dec 11, 1998Closed
Citation 7, item 1
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Serious$0$0Dec 11, 1998Closed
Citation 8, item 1
29 CFR 1910.178(l) · Forklifts and other powered industrial trucks
Serious$0$0Dec 11, 1998Closed
Citation 9, item 1
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Dec 11, 1998Closed
Citation 10, item 1
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$0$0Dec 11, 1998Closed
Citation 10, item 2
29 CFR 1910.219(i)(2) · Belts, pulleys and power-transmission parts
Serious$0$0Dec 11, 1998Closed
Citation 11, item 1
29 CFR 1910.1450(e)(1) · Occupational exposure to hazardous chemicals in laboratories
Serious$0$0Dec 11, 1998Closed
Citation 12, item 1
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0Dec 11, 1998Closed
Citation 12, item 2
29 CFR 1910.119(g)(3) · Process safety management
Other-than-serious$0$0Dec 11, 1998Closed
Citation 12, item 3
29 CFR 1910.119(h)(2)(vi) · Process safety management
Other-than-serious$0$0Dec 11, 1998Closed
Citation 12, item 4
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Dec 11, 1998Closed
Citation 12, item 5
29 CFR 1910.132(f)(4) · Personal protective equipment, general requirements
Other-than-serious$0$0Dec 11, 1998Closed
Citation 12, item 6
29 CFR 1910.134(f)(2)(iv) · Respiratory protection
Other-than-serious$0$0Dec 11, 1998Closed
Citation 12, item 7
29 CFR 1910.147(c)(6)(ii) · Lockout/tagout
Other-than-serious$0$0Dec 11, 1998Closed
Citation 12, item 8
29 CFR 1910.147(c)(7)(iv) · Lockout/tagout
Other-than-serious$0$0Dec 11, 1998Closed
Citation 12, item 9
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0Dec 11, 1998Closed
Citation 12, item 10
29 CFR 1910.178(a)(6) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Dec 11, 1998Closed
Citation 12, item 11
29 CFR 1910.179(j)(2)(iii) · Overhead and gantry cranes
Other-than-serious$0$0Dec 11, 1998Closed
Citation 12, item 12
29 CFR 1910.179(j)(2)(iv) · Overhead and gantry cranes
Other-than-serious$0$0Dec 11, 1998Closed
Citation 12, item 13
29 CFR 1910.179(j)(3) · Overhead and gantry cranes
Other-than-serious$0$0Dec 11, 1998Closed
Citation 12, item 14
29 CFR 1910.244(a)(1)(ii) · Other portable tools and equipment
Other-than-serious$0$0Dec 11, 1998Closed
Citation 12, item 15
29 CFR 1910.1450(f)(3)(i) · Occupational exposure to hazardous chemicals in laboratories
Other-than-serious$0$0Dec 11, 1998Closed
Citation 12, item 16
29 CFR 1910.1450(f)(3)(ii) · Occupational exposure to hazardous chemicals in laboratories
Other-than-serious$0$0Dec 11, 1998Closed
Citation 12, item 17
29 CFR 50405 B01
Other-than-serious$0$0Dec 11, 1998Closed
Citation 12, item 18
29 CFR 50406 A01
Other-than-serious$0$0Dec 11, 1998Closed
Citation 12, item 19 Other-than-serious$0$0Dec 11, 1998Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 0912.2102

29 CFR 1904.39 · Reporting deaths and severe injuries

29 CFR 1904.39(a)(1)

(a) Basic requirement. (1) Within eight (8) hours after the death of any employee as a result of a work-related incident, you must report the fatality to the Occupational Safety and Health Administration (OSHA), U.S. Department of Labor.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(2)(iii)

(iii) Size. Flammable liquid containers shall be in accordance with Table H-12, except that glass or plastic containers of no more than 1-gallon capacity may be used for a Category 1 or 2 flammable liquid if:

29 CFR 1910.119 · Process safety management

29 CFR 1910.119(c)(1)

(c) Employee participation. (1) Employers shall develop a written plan of action regarding the implementation of the employee participation required by this paragraph.

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.140 · Personal fall protection systems

29 CFR 1910.1450 · Occupational exposure to hazardous chemicals in laboratories

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Ladders in general industry

29 CFR 1910.244 · Other portable tools and equipment

29 CFR 1910.30 · Training requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

Other administration of air and water resource and solid waste management programs employers in Maryland

Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.