Inspection 349079525 OPENED MAY 4, 2026Closed
900 West Main Street, Kent, OH 44240 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
US Development Corp. has 3 OSHA inspections on record in Ohio, the first in 2024.
OSHA's last visit started on May 4, 2026 on a referral, in Kent.
Across those inspections OSHA issued 5 citation items: 2 serious and 3 other-than-serious.
OSHA proposed $13,073 in penalties. After settlements and reviews the total is $6,526, down 50%.
Most often, OSHA cited 1910.1200, hazard communication (2 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. US Development Corp. averages $3,263 over 2 cited inspections in that time.
Want to know if OSHA cites US Development Corp. again? Add it to a watchlist and we will email you the morning the citation shows up.
Watch this company900 West Main Street, Kent, OH 44240 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
900 West Main Street, Kent, OH 44240 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.212(a)(3)(ii) · Machine guarding |
Serious | $6,620 | $3,300 | Aug 10, 2026 | Final |
| Citation 2, item 1 29 CFR 1910.147(c)(6)(i)(c) · Lockout/tagout |
Other-than-serious | $0 | $0 | Aug 10, 2026 | Final |
900 West Main Street, Kent, OH 44240 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 OSH Act Section 5(a)(1) · General Duty Clause |
Serious | $6,453 | $3,226 | Jan 3, 2025 | Final |
| Citation 2, item 1a 29 CFR 1910.1200(e)(1)(i) · Hazard communication |
Other-than-serious | $0 | $0 | Jan 3, 2025 | Final |
| Citation 2, item 1b 29 CFR 1910.1200(g)(8) · Hazard communication |
Other-than-serious | $0 | $0 | Jan 3, 2025 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.1200(e)(1)(i)
(i) A list of the hazardous chemicals known to be present using a product identifier that is referenced on the appropriate safety data sheet (the list may be compiled for the workplace as a whole or for individual work areas); and,
29 CFR 1910.1200(g)(8)
(8) The employer shall maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and shall ensure that they are readily accessible during each work shift to employees when they are in their work area(s). (Electronic access and other alternatives to maintaining paper copies of the safety data sheets are permitted as long as no barriers to immediate employee access in each workplace are created by such options.)
29 CFR 1910.147(c)(6)(i)(c)
(C) Where lockout is used for energy control, the periodic inspection shall include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.