OSHA SearchOSHA records by employer

US Geological Survey-Cascades Volcano Observatory: OSHA inspections and violations

Vancouver, Washington · Administration of Conservation Programs · NAICS 924120

4inspections
14citation items
$0current penalties
May 12, 2022last inspection

OSHA has inspected US Geological Survey-Cascades Volcano Observatory 4 times in Washington since 2009.

The latest one began on May 12, 2022 to follow up on an earlier case, in Vancouver.

Those inspections ended with 14 citation items: 4 serious, 4 repeat and 6 other-than-serious.

None of the citations carried a penalty.

Electrical equipment, general requirements comes up most often in these citations: 3 items under 1910.303.

How that compares: the median penalty per cited inspection for public administration employers since 2015 is $0, and US Geological Survey-Cascades Volcano Observatory averages $0 (1 cited inspection).

US Geological Survey-Cascades Volcano Observatory: OSHA citation items per year, 2009 to 2022
Citation items per year, by inspection date.

Washington · latest 90 days of OSHA records

1,015employers cited

Get notified the morning OSHA posts each new citation in Washington: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Washington

Checking a subcontractor, a client or your own company? Watch US Geological Survey-Cascades Volcano Observatory and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345954259 OPENED MAY 12, 2022Closed

Follow-up · Partial · Health · Federal government · 71 employees at the site · Closed May 12, 2022

1300 Southeast Cardinal Court, Building 10, Suite 100, Vancouver, WA 98683 · Research and Development in the Physical, Engineering, and Life Sciences (except Nanotechnology and Biotechnology) · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 345619621 OPENED NOV 3, 2021Closed

Planned · Complete · Health · Federal government · 85 employees at the site · Closed Jan 12, 2022

1300 Southeast Cardinal Court, Building 10, Suite 100, Vancouver, WA 98683 · Research and Development in the Physical, Engineering, and Life Sciences (except Nanotechnology and Biotechnology) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.145(c)(2)(i) · Specifications for accident prevention signs and tags
Serious$0$0Nov 24, 2021Final
Citation 1, item 1b
29 CFR 1910.1025(h)(1) · Lead in general industry
Serious$0$0Nov 24, 2021Final
Citation 1, item 2
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$0$0Nov 24, 2021Final
Citation 2, item 1a
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0Nov 24, 2021Final
Citation 2, item 1b
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Other-than-serious$0$0Nov 24, 2021Final

Inspection 309095826 OPENED JUL 7, 2009Closed

Follow-up · Partial · Health · Federal government · 70 employees at the site · Closed Jul 14, 2009

1300 Se Cardinal Court, Vancouver, WA 98683 · Administration of Conservation Programs · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 309094985 OPENED JAN 13, 2009Closed

Planned · Complete · Health · Federal government · 70 employees at the site · Closed Mar 11, 2009

1300 Se Cardinal Court, Vancouver, WA 98683 · Administration of Conservation Programs · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.242(b) · Hand and power tools
Serious$0$0Feb 5, 2009Closed
Citation 2, item 1
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Repeat$0$0Feb 5, 2009Closed
Citation 2, item 2
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Repeat$0$0Feb 5, 2009Closed
Citation 2, item 3
29 CFR 1910.303(g)(2)(id) · Electrical equipment, general requirements
Repeat$0$0Feb 5, 2009Closed
Citation 2, item 4
29 CFR 1910.305(g)(1)(iva) · Electrical wiring methods
Repeat$0$0Feb 5, 2009Closed
Citation 3, item 1
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Other-than-serious$0$0Feb 5, 2009Closed
Citation 3, item 2
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Feb 5, 2009Closed
Citation 3, item 3
29 CFR 1910.303(g)(1)(i) · Electrical equipment, general requirements
Other-than-serious$0$0Feb 5, 2009Closed
Citation 3, item 4
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Other-than-serious$0$0Feb 5, 2009Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1025 · Lead in general industry

29 CFR 1910.1025(h)(1)

(h) Housekeeping—(1) Surfaces. All surfaces shall be maintained as free as practicable of accumulations of lead.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)(i)

(i) A list of the hazardous chemicals known to be present using a product identifier that is referenced on the appropriate safety data sheet (the list may be compiled for the workplace as a whole or for individual work areas); and,

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(2)(i)

(i) An employer may provide respirators at the request of employees or permit employees to use their own respirators, if the employer determines that such respirator use will not in itself create a hazard. If the employer determines that any voluntary respirator use is permissible, the employer shall provide the respirator users with the information contained in appendix D to this section (“Information for Employees Using Respirators When Not Required Under the Standard”); and

29 CFR 1910.145 · Specifications for accident prevention signs and tags

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

Other administration of conservation programs employers in Washington

Alert subscribers get notified of each newly cited employer in Washington the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.