OSHA SearchOSHA records by employer

Valley Joist, LLC: OSHA inspections and violations

Fernley, Nevada · Fabricated Structural Metal Manufacturing · NAICS 332312

16inspections
41citation items
$12,150current penalties
Sep 24, 2021last inspection

OSHA has inspected Valley Joist, LLC 16 times in Nevada since 1998.

The latest one began on Sep 24, 2021 after an accident, in Fernley.

Those inspections ended with 41 citation items: 10 serious and 31 other-than-serious.

Penalties were first proposed at $12,150 and still stand at $12,150.

Forklifts and other powered industrial trucks comes up most often in these citations: 4 items under 1910.178.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Valley Joist, LLC averages $0 (3 cited inspections).

Valley Joist, LLC also files yearly injury logs with OSHA, summarized below.

Valley Joist, LLC: OSHA citation items per year, 1998 to 2021
Citation items per year, by inspection date.

Nevada · latest 90 days of OSHA records

114employers cited

Get notified the morning OSHA posts each new citation in Nevada: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Nevada

Checking a subcontractor, a client or your own company? Watch Valley Joist, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345547004 OPENED SEP 24, 2021Closed

Accident · Partial · Safety · 115 employees at the site · Closed Jul 10, 2023

255 Logan Lane, Fernley, NV 89408 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Sep 17, 2021: Employee struck by lumber breaks leg when caught in stairs

At 12:30 p.m. on September 17, 2021, an employee working as a welder for a structural components manufacturer was spotting a powered industrial vehicle (PIV). The employee was clearing a jam in the lumber while a coworker placed the lumber on a rack using a PIV. The coworker moved forward striking the employee with a stack of 10-foot-long lumber. The employee fell to the ground, catching his left foot between the stair steps. The employee was hospitalized to treat a broken lower left leg.

No citations from this inspection.

Inspection 344275144 OPENED AUG 30, 2019Closed

Complaint · Complete · Health · 85 employees at the site · Closed Sep 6, 2019

255 Logan Road, Fernley, NV 89408 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344256847 OPENED AUG 23, 2019Closed

Complaint · Partial · Safety · 85 employees at the site · Closed Nov 15, 2022

255 Logan Road, Fernley, NV 89408 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.133(a)(5) · Eye and face protection
Other-than-serious$0$0Oct 16, 2019Final
Citation 1, item 2
29 CFR 1910.252(b)(2)(iii) · Welding fire safety
Other-than-serious$0$0Oct 16, 2019Final

Inspection 343954947 OPENED APR 22, 2019Closed

Planned · Complete · Health · 85 employees at the site · Closed Sep 23, 2019

255 Logan Road, Fernley, NV 89408 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.146(c)(2) · Permit-required confined spaces
Other-than-serious$0$0Aug 27, 2019Final

Inspection 343960514 OPENED APR 22, 2019Closed

Planned · Complete · Safety · 85 employees at the site · Closed Sep 23, 2019

255 Logan Road, Fernley, NV 89408 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.179(g)(1)(v) · Overhead and gantry cranes
Other-than-serious$0$0Aug 27, 2019Final

Inspection 313858888 OPENED OCT 8, 2009Closed

Planned · Complete · Health · 43 employees at the site · Closed Oct 22, 2009

255 Logan Road, Fernley, NV 89408 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Oct 14, 2009Closed

Inspection 313858813 OPENED OCT 7, 2009Closed

Planned · Complete · Safety · 43 employees at the site · Closed Nov 3, 2009

255 Logan Road, Fernley, NV 89408 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Oct 8, 2009Closed
Citation 1, item 2
29 CFR 1910.303(b)(7)(iv) · Electrical equipment, general requirements
Other-than-serious$0$0Oct 8, 2009Closed
Citation 1, item 3
29 CFR 1910.254(d)(8) · Arc welding and cutting
Other-than-serious$0$0Oct 8, 2009Closed
Citation 1, item 4
29 CFR 1910.305(g)(1)(iva) · Electrical wiring methods
Other-than-serious$0$0Oct 8, 2009Closed
Citation 1, item 5
29 CFR 1910.243(c)(1) · Guarding of portable powered tools
Other-than-serious$0$0Oct 8, 2009Closed
Citation 1, item 6
29 CFR 1910.253(e)(1) · Gas welding and cutting
Other-than-serious$0$0Oct 8, 2009Closed
Citation 1, item 7
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Oct 8, 2009Closed
Citation 1, item 8
29 CFR 1910.37(a)(4) · Exit routes
Other-than-serious$0$0Oct 8, 2009Closed
Citation 1, item 9
29 CFR 1910.157(c)(4) · Portable fire extinguishers
Other-than-serious$0$0Oct 8, 2009Closed
Citation 1, item 10 Other-than-serious$0$0Oct 8, 2009Closed
Citation 1, item 11 Other-than-serious$0$0Oct 8, 2009Closed

Inspection 310832936 OPENED MAR 2, 2007Closed

Complaint · Partial · Safety · 100 employees at the site · Closed Mar 2, 2007

255 Logan Road, Fernley, NV 89408 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(b)(1)(iii) · Electrical equipment, general requirements
Other-than-serious$0$0Mar 2, 2007Closed
8 older inspections

Inspection 310067160 OPENED JUN 1, 2006Closed

Complaint · Partial · Safety · 100 employees at the site · Closed Jun 1, 2006

255 Logan Road, Fernley, NV 89408 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 308256296 OPENED OCT 18, 2004Closed

Planned · Complete · Safety · 80 employees at the site · Closed Nov 3, 2004

255 Logan Road, Fernley, NV 89408 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Other-than-serious$0$0Oct 18, 2004Closed
Citation 1, item 2
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$0$0Oct 18, 2004Closed

Inspection 305868143 OPENED SEP 13, 2002Closed

Complaint · Partial · Health · 117 employees at the site · Closed Sep 16, 2002

255 Logan Road, Fernley, NV 89408 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 305083289 OPENED MAY 3, 2002Closed

Referral · Partial · Safety · 122 employees at the site · Closed Jul 26, 2002

255 Logan Road, Fernley, NV 89408 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Serious$780$780Jun 5, 2002Closed
Citation 1, item 1b
29 CFR 1910.178(l)(6) · Forklifts and other powered industrial trucks
Serious$0$0Jun 5, 2002Closed
Citation 1, item 2
29 CFR 1910.178(m)(3) · Forklifts and other powered industrial trucks
Serious$780$780Jun 5, 2002Closed

Inspection 304583404 OPENED AUG 7, 2001Closed

Follow-up · Partial · Health · 94 employees at the site · Closed Aug 23, 2001

255 Logan Road, Fernley, NV 89408 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 304284094 OPENED MAR 5, 2001Closed

Complaint · Complete · Health · 94 employees at the site · Closed Aug 23, 2001

255 Logan Road, Fernley, NV 89408 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$420$420Apr 5, 2001Closed
Citation 1, item 2a
29 CFR 1910.1000(a)(2) · Air contaminants
Serious$420$420Apr 5, 2001Closed
Citation 1, item 2b
29 CFR 1910.1000(e) · Air contaminants
Serious$0$0Apr 5, 2001Closed
Citation 2, item 1
29 CFR 1910.22(a)(3) · General requirements
Other-than-serious$0$0Mar 30, 2001Closed
Citation 2, item 2
29 CFR 1910.178(a)(4) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Mar 30, 2001Closed
Citation 2, item 3
29 CFR 1910.106(e)(6)(i) · Flammable liquids
Other-than-serious$0$0Mar 30, 2001Closed
Citation 2, item 4
29 CFR 1910.180(e)(1) · Crawler locomotive and truck cranes
Other-than-serious$0$0Mar 30, 2001Closed
Citation 2, item 5
29 CFR 1910.180(f) · Crawler locomotive and truck cranes
Other-than-serious$0$0Mar 30, 2001Closed

Inspection 302800792 OPENED JUN 25, 1999Closed

Referral · Partial · Safety · 180 employees at the site · Closed Jun 25, 1999

255 Logan Road, Fernley, NV 89408 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 302476882 OPENED DEC 1, 1998Closed

Referral · Complete · Safety · 115 employees at the site · Closed Mar 10, 1999

255 Logan Road, Fernley, NV 89408 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$1,375$1,375Jan 11, 1999Closed
Citation 1, item 2
29 CFR 1910.179(j)(1)(ii) · Overhead and gantry cranes
Serious$1,375$1,375Jan 11, 1999Closed
Citation 1, item 3
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$3,500$3,500Jan 11, 1999Closed
Citation 1, item 4 Serious$3,500$3,500Jan 11, 1999Closed
Citation 2, item 1
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Other-than-serious$0$0Dec 7, 1998Closed
Citation 2, item 2
29 CFR 1910.179(g)(1)(v) · Overhead and gantry cranes
Other-than-serious$0$0Dec 7, 1998Closed
Citation 2, item 3
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Other-than-serious$0$0Dec 7, 1998Closed
Citation 2, item 4
29 CFR 1910.157(g)(1) · Portable fire extinguishers
Other-than-serious$0$0Dec 7, 1998Closed
Citation 2, item 5
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Dec 7, 1998Closed
Citation 2, item 6
29 CFR 1910.146(c)(1) · Permit-required confined spaces
Other-than-serious$0$0Dec 7, 1998Closed
Citation 2, item 7
29 CFR 1910.38(a)(1) · Emergency action plans
Other-than-serious$0$0Dec 7, 1998Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Fernley site logged 4 recordable injuries or illnesses among about 84 workers: 4.6 per 100 full-time workers, against a median of 3.6 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Valley Joist West
Fernley · 2025
84 404.63.6
Steel Manufacturing
Fernley · 2018
140 1228.43.6

Included with any plan: 8 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1000 · Air contaminants

29 CFR 1910.1000(a)(2)

(2) Other substances—8-hour Time Weighted Averages. An employee's exposure to any substance in Table Z-1, the exposure limit of which is not preceded by a “C”, shall not exceed the 8-hour Time Weighted Average given for that substance in any 8-hour work shift of a 40-hour work week.

29 CFR 1910.1000(e)

(e) To achieve compliance with paragraphs (a) through (d) of this section, administrative or engineering controls must first be determined and implemented whenever feasible. When such controls are not feasible to achieve full compliance, protective equipment or any other protective measures shall be used to keep the exposure of employees to air contaminants within the limits prescribed in this section. Any equipment and/or technical measures used for this purpose must be approved for each particular use by a competent industrial hygienist or other technically qualified person. Whenever respirators are used, their use shall comply with 1910.134.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(6)(i)

(6) Sources of ignition—(i) General. Adequate precautions shall be taken to prevent the ignition of flammable vapors. Sources of ignition include but are not limited to open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.180 · Crawler locomotive and truck cranes

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.22 · General requirements

29 CFR 1910.243 · Guarding of portable powered tools

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.254 · Arc welding and cutting

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.37 · Exit routes

29 CFR 1910.38 · Emergency action plans

29 CFR 6180.3750

29 CFR 6180.5400

Other fabricated structural metal manufacturing employers in Nevada

Alert subscribers get notified of each newly cited employer in Nevada the morning it is posted. See the alert plans.