OSHA SearchOSHA records by employer

Valley Service Mechanical, LLC: OSHA inspections and violations

Fargo, North Dakota · Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance · NAICS 811310

1inspections
2citation items
$14,502current penalties
Feb 25, 2022last inspection

OSHA inspectors have visited Valley Service Mechanical, LLC in North Dakota one time.

It opened on Feb 25, 2022 after a fatality or catastrophe, in Fargo.

In all, OSHA issued 2 citation items: 2 serious.

The proposed penalties came to $20,302; today they stand at $14,502, 29% less.

The rule cited most here is 1910.147 (lockout/tagout), 2 times.

Among repair and personal services employers, the typical cited inspection since 2015 ends with a $1,200 penalty. Valley Service Mechanical, LLC averages $14,502 across 1 cited inspection.

1 inspection on this page followed a fatal incident.

Valley Service Mechanical, LLC: OSHA citation items per year, 2022 to 2022
Citation items per year, by inspection date.

North Dakota · latest 90 days of OSHA records

30employers cited

Get notified the morning OSHA posts each new citation in North Dakota: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Dakota

Checking a subcontractor, a client or your own company? Watch Valley Service Mechanical, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345803274 OPENED FEB 25, 2022Closed

Fatality or catastrophe · Partial · Safety · 30 employees at the site · Closed Aug 29, 2022

1441 44th Street North, Fargo, ND 58102 · Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance · OSHA's record · Phone and website on Google Maps

Incident on Feb 24, 2022 (fatal): Employee is electrocuted while replacing air ventilator

At 4:30 p.m. on February 24, 2022, an employee of Valley Service Mechanical was replacing a combustion air ventilator (Bryant Model 580JE08D180A2A0AAA; Serial Number 3013G10004) without locking out the equipment. The employee came into contact with live electrical or stored energy from the capacitor and was killed.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(7)(i)(a) · Lockout/tagout
Serious$10,151$14,502Aug 2, 2022Final
Citation 1, item 1b
29 CFR 1910.147(d)(5)(i) · Lockout/tagout
Serious$10,151$0Aug 2, 2022Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(7)(i)(a)

(A) Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.

29 CFR 1910.147(d)(5)(i)

(5) Stored energy. (i) Following the application of lockout or tagout devices to energy isolating devices, all potentially hazardous stored or residual energy shall be relieved, disconnected, restrained, and otherwise rendered safe.

Other commercial and industrial machinery and equipment (except automotive and electronic) repair and maintenance employers in North Dakota

Alert subscribers get notified of each newly cited employer in North Dakota the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.