OSHA SearchOSHA records by employer

Vasq Sheetmetal, LLC: OSHA inspections and violations

Arlington, Texas · Sheet Metal Work Manufacturing · NAICS 332322

3inspections
9citation items
$24,600current penalties
Apr 7, 2022last inspection

OSHA has inspected Vasq Sheetmetal, LLC 3 times in Texas since 2017.

The latest one began on Apr 7, 2022 on a referral, in Prosper.

Those inspections ended with 9 citation items: 8 serious and 1 other-than-serious.

Penalties were first proposed at $37,274 and now stand at $24,600, 34% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Vasq Sheetmetal, LLC averages $8,200 (3 cited inspections).

The Wage and Hour Division has 1 case on it since 2015, with $62,907 in back wages owed to workers.

Vasq Sheetmetal, LLC: OSHA citation items per year, 2017 to 2022
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

393employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Vasq Sheetmetal, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345884530 OPENED APR 7, 2022Closed

Referral · Complete · Safety · 5 employees at the site · Closed Jun 22, 2026

3500 E 1st St., Prosper, TX 75078 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(4)(i) · Fall protection in construction
Serious$10,151$10,151Jul 14, 2022Final

Inspection 342586898 OPENED AUG 25, 2017Closed

Referral · Partial · Health · 30 employees at the site · Closed Nov 26, 2018

1216 Avenue H E, Arlington, TX 76011 · Sheet Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$5,070$3,042Oct 27, 2017Final
Citation 1, item 2
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$3,802$2,281Oct 27, 2017Final

Inspection 342482965 OPENED JUL 20, 2017Closed

Complaint · Partial · Safety · 34 employees at the site · Closed Apr 3, 2023

1216 Avenue H E, Arlington, TX 76011 · Sheet Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.37(a)(1) · Exit routes
Serious$3,422$1,711Sep 14, 2017Final
Citation 1, item 2
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Serious$3,422$1,711Sep 14, 2017Final
Citation 1, item 3
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$4,563$2,282Sep 14, 2017Final
Citation 1, item 4
29 CFR 1910.243(c)(3) · Guarding of portable powered tools
Serious$3,422$1,711Sep 14, 2017Final
Citation 1, item 5
29 CFR 1910.253(b)(2)(ii) · Gas welding and cutting
Serious$3,422$1,711Sep 14, 2017Final
Citation 2, item 1 Other-than-serious$0$0Sep 14, 2017Final

Wage and hour cases

Cases by the Labor Department's Wage and Hour Division since 2015: unpaid minimum wage or overtime, child labor, family leave and more.

Period reviewedViolationsWorkers owedBack wagesPenalties
Jul 22, 2015 to Jul 21, 2017
Arlington
1514$62,907$0

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(1)

(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.

29 CFR 1910.141 · Sanitation

29 CFR 1910.141(a)(3)(i)

(3) Housekeeping. (i) All places of employment shall be kept clean to the extent that the nature of the work allows.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.243 · Guarding of portable powered tools

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.37 · Exit routes

29 CFR 1926.501 · Fall protection in construction

Other sheet metal work manufacturing employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.