OSHA SearchOSHA records by employer

Veko Construction, LLC: OSHA inspections and violations

Auburn, Alabama · Masonry Contractors · NAICS 238140

2inspections
11citation items
$27,510current penalties
Jun 12, 2019last inspection

Veko Construction, LLC has 2 OSHA inspections on record in Alabama, the first in 2018.

OSHA's last visit started on Jun 12, 2019 as a planned inspection, in Auburn.

Across those inspections OSHA issued 11 citation items: 7 serious, 3 repeat and 1 other-than-serious.

OSHA proposed $32,405 in penalties. After settlements and reviews the total is $27,510, down 15%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (9 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Veko Construction, LLC averages $13,755 over 2 cited inspections in that time.

Veko Construction, LLC: OSHA citation items per year, 2018 to 2019
Citation items per year, by inspection date.

Alabama · latest 90 days of OSHA records

100employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Alabama: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Alabama

Checking a subcontractor, a client or your own company? Watch Veko Construction, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344074141 OPENED JUN 12, 2019Closed

Planned · Partial · Safety · 6 employees at the site · Closed May 20, 2024

1305 Sunnyslope Ct. Lot 13, Auburn, AL 36830 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1)(ii) · Scaffolds, general requirements
Serious$2,842$2,842Jun 17, 2019Final
Citation 1, item 1b
29 CFR 1926.451(e)(4)(xii) · Scaffolds, general requirements
Serious$0$0Jun 17, 2019Final
Citation 2, item 1
29 CFR 1926.451(b)(5)(i) · Scaffolds, general requirements
Repeat$5,683$5,683Jun 17, 2019Final
Citation 2, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Repeat$5,683$5,683Jun 17, 2019Final
Citation 2, item 3
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Repeat$5,683$5,683Jun 17, 2019Final
Citation 3, item 1
29 CFR 1903.19(c)(1) · Proving cited hazards were fixed
Other-than-serious$319$319Oct 5, 2019Final

Inspection 343291316 OPENED JUL 12, 2018Closed

Planned · Partial · Safety · 5 employees at the site · Closed Apr 8, 2020

2615 Dunkirk Circle Lot 208 East Richland, Auburn, AL 36832 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$3,326$1,825Jul 20, 2018Final
Citation 1, item 1b
29 CFR 1926.451(b)(5)(i) · Scaffolds, general requirements
Serious$0$0Jul 20, 2018Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,217$1,825Jul 20, 2018Final
Citation 1, item 3
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$3,326$1,825Jul 20, 2018Final
Citation 1, item 4
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$3,326$1,825Jul 20, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1903.19 · Proving cited hazards were fixed

29 CFR 1903.19(c)(1)

(c) Abatement certification. (1) Within 10 calendar days after the abatement date, the employer must certify to OSHA (the Agency) that each cited violation has been abated, except as provided in paragraph (c)(2) of this section.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(ii)

(ii) Where the employer makes the demonstration provided for in paragraph (b)(1)(i) of this section, the platform shall be planked or decked as fully as possible and the remaining open space between the platform and the uprights shall not exceed 9 1/2 inches (24.1 cm).

29 CFR 1926.451(b)(2)

(2) Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and walkway shall be at least 18 inches (46 cm) wide.

29 CFR 1926.501 · Fall protection in construction

Other masonry contractors employers in Alabama

Alert subscribers get notified of each newly cited employer in Alabama the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.