OSHA SearchOSHA records by employer

Victor Paz: OSHA inspections and violations

Irving, Texas · Framing Contractors · NAICS 238130

8inspections
18citation items
$111,052current penalties
Apr 14, 2026last inspection

Since 2012, OSHA inspectors have visited Victor Paz in Texas 8 times.

The most recent inspection opened on Apr 14, 2026 as a planned inspection, in The Colony and is still open.

In all, OSHA issued 18 citation items: 11 serious and 7 repeat.

The penalties, $111,052 in total, stand where OSHA first set them.

The rule cited most here is 1926.451 (scaffolds, general requirements), 10 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Victor Paz averages $20,010 across 5 cited inspections.

Victor Paz: OSHA citation items per year, 2012 to 2026
Citation items per year, by inspection date.

Want to know if OSHA cites Victor Paz again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 348912551 OPENED APR 14, 2026Open

Planned · Partial · Safety · 6 employees at the site · Open

3716 Pierce Lane, The Colony, TX 75056 · Framing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection so far.

Inspection 348378381 OPENED JUL 11, 2025Open

Planned · Partial · Safety · 5 employees at the site · Open

8948 Magnet Drive, Frisco, TX 75033 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$4,256$4,256Jan 7, 2026Final
Citation 1, item 2
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$4,965$4,965Jan 7, 2026Final

Inspection 344291844 OPENED AUG 30, 2019Closed

Planned · Partial · Safety · 4 employees at the site · Closed Mar 28, 2023

1492 Windermere Way, Farmers Branch, TX 75234 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(c)(2)(ii) · Scaffolds, general requirements
Serious$4,376$4,376Nov 13, 2019Final
Citation 1, item 2
29 CFR 1926.452(j)(1) · Rules for each type of scaffold
Serious$3,126$3,126Nov 13, 2019Final
Citation 2, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Repeat$21,879$21,879Nov 13, 2019Final

Inspection 344101712 OPENED JUN 20, 2019Closed

Planned · Partial · Safety · 4 employees at the site · Closed Oct 11, 2022

3519 Calico Dr., Irving, TX 75061 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Repeat$19,890$19,890Jul 5, 2019Final

Inspection 341370120 OPENED APR 1, 2016Closed

Planned · Partial · Safety · 5 employees at the site · Closed Sep 20, 2019

8129 Whistling Duck Drive, Fort Worth, TX 76118 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$1,760$1,760May 12, 2016Final
Citation 2, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Repeat$2,640$2,640May 12, 2016Final
Citation 2, item 2
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Repeat$5,280$5,280May 12, 2016Final
Citation 2, item 3
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Repeat$15,400$15,400May 12, 2016Final
Citation 2, item 4
29 CFR 1926.452(a)(4) · Rules for each type of scaffold
Repeat$5,280$5,280May 12, 2016Final

Inspection 340486745 OPENED MAR 12, 2015Closed

Planned · Partial · Safety · 4 employees at the site · Closed Aug 13, 2018

2408 Barclay Court, Plano, TX 75074 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$2,800$2,800Jun 9, 2015Final
Citation 1, item 2
29 CFR 1926.452(a)(4) · Rules for each type of scaffold
Serious$2,800$2,800Jun 9, 2015Final
Citation 2, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Repeat$5,600$5,600Jun 9, 2015Final

Inspection 339750325 OPENED APR 30, 2014Closed

Planned · Partial · Safety · 5 employees at the site · Closed Mar 26, 2019

3804 Canton Jade Way, Arlington, TX 76012 · Finish Carpentry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,800$2,800Jun 20, 2014Final
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$1,600$1,600Jun 20, 2014Final

Inspection 316094457 OPENED MAR 1, 2012Closed

Planned · Partial · Safety · 10 employees at the site · Closed May 15, 2016

688 Arbol, Irving, TX 75039 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$2,400$2,400Apr 11, 2012Closed
Citation 1, item 2
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$4,200$4,200Apr 11, 2012Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(2)

(2) Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and walkway shall be at least 18 inches (46 cm) wide.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.501 · Fall protection in construction

Other framing contractors employers in Texas

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.