OSHA SearchOSHA records by employer

Vulcan Corporation: OSHA inspections and violations

Clarksville, Tennessee · All Other Rubber Product Manufacturing · NAICS 326299

6inspections
29citation items
$13,650current penalties
Oct 18, 2017last inspection

OSHA has inspected Vulcan Corporation 6 times in Tennessee since 1988.

The latest one began on Oct 18, 2017 as a planned inspection, in Clarksville.

Those inspections ended with 29 citation items: 19 serious and 10 other-than-serious.

Penalties were first proposed at $15,300 and now stand at $13,650, 11% lower after settlements or reviews.

Belts, pulleys and power-transmission parts comes up most often in these citations: 4 items under 1910.219.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and Vulcan Corporation averages $12,000 (1 cited inspection).

Vulcan Corporation: OSHA citation items per year, 1988 to 2017
Citation items per year, by inspection date.

Tennessee · latest 90 days of OSHA records

342employers cited

Get notified the morning OSHA posts each new citation in Tennessee: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Tennessee

Checking a subcontractor, a client or your own company? Watch Vulcan Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342712874 OPENED OCT 18, 2017Closed

Planned · Complete · Safety · 35 employees at the site · Closed Dec 22, 2017

1151 College Street, Clarksville, TN 37040 · All Other Rubber Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.110(e)(4)(iii) · Storage and handling of liquefied petroleum gases
Serious$1,200$1,200Nov 17, 2017Final
Citation 1, item 1b
29 CFR 1910.178(a)(6) · Forklifts and other powered industrial trucks
Serious$0$0Nov 17, 2017Final
Citation 1, item 1c
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Serious$0$0Nov 17, 2017Final
Citation 1, item 1d
29 CFR 1910.178(q)(6) · Forklifts and other powered industrial trucks
Serious$0$0Nov 17, 2017Final
Citation 1, item 2a
29 CFR 1910.147(c)(4)(ii) · Lockout/tagout
Serious$1,200$1,200Nov 17, 2017Final
Citation 1, item 2b Serious$0$0Nov 17, 2017Final
Citation 1, item 3
29 CFR 1910.147(e)(3) · Lockout/tagout
Serious$1,500$1,500Nov 17, 2017Final
Citation 1, item 4
29 CFR 1910.178(m)(5)(i) · Forklifts and other powered industrial trucks
Serious$800$800Nov 17, 2017Final
Citation 1, item 5
29 CFR 1910.212(a)(1) · Machine guarding
Serious$1,600$1,600Nov 17, 2017Final
Citation 1, item 6
29 CFR 1910.212(b) · Machine guarding
Serious$800$800Nov 17, 2017Final
Citation 1, item 7
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$800$800Nov 17, 2017Final
Citation 1, item 8a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$1,200$1,200Nov 17, 2017Final
Citation 1, item 8b
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Nov 17, 2017Final
Citation 1, item 9
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$1,200$1,200Nov 17, 2017Final
Citation 1, item 10
29 CFR 1910.252(b)(4)(v) · Welding fire safety
Serious$800$800Nov 17, 2017Final
Citation 1, item 11
29 CFR 1910.254(d)(9)(iii) · Arc welding and cutting
Serious$800$800Nov 17, 2017Final
Citation 2, item 1
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$100$100Nov 17, 2017Final

Inspection 114509573 OPENED MAY 6, 1994Closed

Referral · Partial · Health · 238 employees at the site · Closed Aug 12, 1994

1151 East Pettus St, Clarksville, TN 37041 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$1,600$800Jun 3, 1994Closed
Citation 1, item 2a
29 CFR 1910.1200(g)(8) · Hazard communication
Serious$1,400$700Jun 3, 1994Closed
Citation 1, item 2b
29 CFR 1910.1200(h)(2)(ii) · Hazard communication
Serious$0$0Jun 3, 1994Closed
Citation 2, item 1 Other-than-serious$300$150Jun 3, 1994Closed

Inspection 108212820 OPENED FEB 13, 1989Closed

Complaint · Partial · Health · 280 employees at the site · Closed Mar 1, 1989

1151 East Pettus St, Clarksville, TN 37041 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 105555262 OPENED MAY 9, 1988Closed

Complaint · Partial · Health · 333 employees at the site · Closed Sep 13, 1988

1151 East Pettus St, Clarksville, TN 37041 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.1200(f)(4)(ii) · Hazard communication
Other-than-serious$0$0Jul 28, 1988Closed
Citation 1, item 1b
29 CFR 1910.1200(h)(2)(i) · Hazard communication
Other-than-serious$0$0Jul 28, 1988Closed

Inspection 105556971 OPENED MAY 9, 1988Closed

Complaint · Partial · Safety · 333 employees at the site · Closed May 9, 1988

1151 East Pettus St, Clarksville, TN 37041 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 105541056 OPENED FEB 24, 1988Closed

Planned · Complete · Safety · 333 employees at the site · Closed May 4, 1988

1151 East Pettus St, Clarksville, TN 37041 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Other-than-serious$0$0Mar 1, 1988Closed
Citation 1, item 2
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Other-than-serious$0$0Mar 1, 1988Closed
Citation 1, item 3
29 CFR 1910.106(d)(4)(iv) · Flammable liquids
Other-than-serious$0$0Mar 1, 1988Closed
Citation 1, item 4
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$0$0Mar 1, 1988Closed
Citation 1, item 5
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0Mar 1, 1988Closed
Citation 1, item 6
29 CFR 1910.304(f)(5)(v) · Grounding and circuit protection
Other-than-serious$0$0Mar 1, 1988Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(4)(i)

(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra

29 CFR 1910.106(d)(4)(iv)

(iv) Ventilation. Every inside storage room shall be provided with either a gravity or a mechanical exhaust ventilation system. Such system shall be designed to provide for a complete change of air within the room at least six times per hour. If a mechanical exhaust system is used, it shall be controlled by a switch located outside of the door. The ventilating equipment and any lighting fixtures shall be operated by the same switch. A pilot light shall be installed adjacent to the switch if Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), are dispensed within the room. Where gravity ventilation is provided, the fresh air intake, as well as the exhaust outlet from the room, shall be on the exterior of the building in which the room is located.

29 CFR 1910.110 · Storage and handling of liquefied petroleum gases

29 CFR 1910.110(e)(4)(iii)

(iii) Permanent and removable fuel containers shall be securely mounted to prevent jarring loose, slipping, or rotating, and the fastenings shall be designed and constructed to withstand static loading in any direction equal to twice the weight of the tank and attachments when filled with fuel using a safety factor of not less than four based on the ultimate strength of the material to be used. Field welding, when necessary, shall be made only on saddle plates, lugs or brackets, originally attached to the container by the tank manufacturer.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.141 · Sanitation

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.254 · Arc welding and cutting

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.95 · Noise

Other all other rubber product manufacturing employers in Tennessee

Alert subscribers get notified of each newly cited employer in Tennessee the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.