OSHA SearchOSHA records by employer

W.E.B. Construction Inc.: OSHA inspections and violations

Lawton, Oklahoma · Water and Sewer Line and Related Structures Construction · NAICS 237110

4inspections
13citation items
$106,074current penalties
Apr 1, 2025last inspection

W.E.B. Construction Inc. has 4 OSHA inspections on record in Oklahoma, the first in 2020.

OSHA's last visit started on Apr 1, 2025 as a planned inspection, in Harrah, and the case has not closed yet.

Across those inspections OSHA issued 13 citation items: 7 serious, 4 repeat and 2 other-than-serious.

OSHA proposed $118,599 in penalties. After settlements and reviews the total is $106,074, down 11%.

Most often, OSHA cited 1926.651, excavations (8 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. W.E.B. Construction Inc. averages $26,518 over 4 cited inspections in that time.

W.E.B. Construction Inc.: OSHA citation items per year, 2020 to 2025
Citation items per year, by inspection date.

Want to know if OSHA cites W.E.B. Construction Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 348151713 OPENED APR 1, 2025Open

Planned · Partial · Safety · 15 employees at the site · Open

E Reno Ave. & S. Harrah Rd., Harrah, OK 73045 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$6,620$6,620Jun 30, 2025Contested
Citation 1, item 2
29 CFR 1926.651(e) · Excavations
Serious$6,620$6,620Jun 30, 2025Contested
Citation 1, item 3
29 CFR 1926.651(h)(1) · Excavations
Serious$6,620$6,620Jun 30, 2025Contested
Citation 2, item 1
29 CFR 1926.651(c)(2) · Excavations
Repeat$13,240$13,240Jun 30, 2025Contested

Inspection 348101148 OPENED MAR 10, 2025Open

Planned · Complete · Safety · 15 employees at the site · Open

4330 Cache Road, Lawton, OK 73505 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(k)(1) · Excavations
Serious$7,282$7,282Jun 30, 2025Contested
Citation 2, item 1
29 CFR 1926.651(c)(2) · Excavations
Repeat$14,564$14,564Jun 30, 2025Contested
Citation 2, item 2
29 CFR 1926.651(j)(2) · Excavations
Repeat$14,564$14,564Jun 30, 2025Contested
Citation 2, item 3
29 CFR 1926.652(a)(1) · Trench protection
Repeat$14,564$14,564Jun 30, 2025Contested

Inspection 347640195 OPENED JUL 24, 2024Open

Planned · Complete · Safety · 16 employees at the site · Open

53rd And Cache, Lawton, OK 73501 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$6,452$4,500Jan 8, 2025Final
Citation 2, item 1
29 CFR 1926.652(a)(1) · Trench protection
Serious$14,195$10,500Jan 8, 2025Final

Inspection 344832886 OPENED JUL 13, 2020Closed

Planned · Complete · Safety · 15 employees at the site · Closed Jun 9, 2021

Corner Of Britton And Sooner Road, Oklahoma City, OK 73114 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.651(c)(2) · Excavations
Other-than-serious$4,626$3,500Aug 10, 2020Final
Citation 1, item 1b
29 CFR 1926.651(j)(2) · Excavations
Other-than-serious$4,626$0Aug 10, 2020Final
Citation 1, item 3
29 CFR 1926.652(a)(1) · Trench protection
Serious$4,626$3,500Aug 10, 2020Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.651(e)

(e) Exposure to falling loads. No employee shall be permitted underneath loads handled by lifting or digging equipment. Employees shall be required to stand away from any vehicle being loaded or unloaded to avoid being struck by any spillage or falling materials. Operators may remain in the cabs of vehicles being loaded or unloaded when the vehicles are equipped, in accordance with § 1926.601(b)(6), to provide adequate protection for the operator during loading and unloading operations.

29 CFR 1926.652 · Trench protection

OSH Act Section 5 · General Duty Clause

Other water and sewer line and related structures construction employers in Oklahoma

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.