OSHA SearchOSHA records by employer

Wacker Neuson America Corporation: OSHA inspections and violations

Menomonee Falls, Wisconsin · All Other Miscellaneous Fabricated Metal Product Manufacturing · NAICS 332999

2inspections
3citation items
$4,145current penalties
Jan 24, 2023last inspection

Wacker Neuson America Corporation has 2 OSHA inspections on record in Wisconsin, the first in 2021.

OSHA's last visit started on Jan 24, 2023 on a referral, in Menomonee Falls.

Across those inspections OSHA issued 3 citation items: 1 serious and 2 other-than-serious.

OSHA proposed $8,290 in penalties. After settlements and reviews the total is $4,145, down 50%.

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Wacker Neuson America Corporation averages $4,145 over 1 cited inspection in that time.

Wacker Neuson America Corporation also files yearly injury logs with OSHA, summarized below.

It reported 1 severe injury to OSHA since 2015.

Wacker Neuson America Corporation: OSHA citation items per year, 2021 to 2023
Citation items per year, by inspection date.

Wisconsin · latest 90 days of OSHA records

216employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wisconsin

Checking a subcontractor, a client or your own company? Watch Wacker Neuson America Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346455116 OPENED JAN 24, 2023Closed

Referral · Partial · Safety · 420 employees at the site · Closed Mar 3, 2023

N92 W15000 Anthony Avenue, Menomonee Falls, WI 53051 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 345604698 OPENED OCT 27, 2021Closed

Complaint · Partial · Safety · 356 employees at the site · Closed Feb 2, 2022

N92 W15000 Anthony Avenue, Menomonee Falls, WI 53051 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.176(b) · Material storage and aisles
Serious$8,290$4,145Dec 16, 2021Final
Citation 2, item 1
29 CFR 1910.178(h)(2) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Dec 16, 2021Final
Citation 2, item 2
29 CFR 1910.303(g)(2)(ii) · Electrical equipment, general requirements
Other-than-serious$0$0Dec 16, 2021Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Menomonee Falls site logged 8 recordable injuries or illnesses among about 372 workers: 1.9 per 100 full-time workers, against a median of 2.7 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Wacker Neuson America Corporation
Menomonee Falls · 2025
372 801.92.7

Included with any plan: 3 more yearly logs from these sites, back to 2022, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Jan 17, 2023, Menomonee Falls: Hospitalization · crushing injuries · arm(s), unspecified

On January 17, 2023, an employee was using an overhead crane to assemble a skid steer. As the crane was lifting the skid steer cab into place over the chassis, the cab dislodged from the crane and pinned the employee between the skid steer cab and the skid steer chassis. The employee sustained a crushing injury to the right arm.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.176 · Material storage and aisles

29 CFR 1910.176(b)

(b) Secure storage. Storage of material shall not create a hazard. Bags, containers, bundles, etc., stored in tiers shall be stacked, blocked, interlocked and limited in height so that they are stable and secure against sliding or collapse.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.178(h)(2)

(2) Where general lighting is less than 2 lumens per square foot, auxiliary directional lighting shall be provided on the truck.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(g)(2)(ii)

(ii) In locations where electric equipment is likely to be exposed to physical damage, enclosures or guards shall be so arranged and of such strength as to prevent such damage.

Other all other miscellaneous fabricated metal product manufacturing employers in Wisconsin

Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.